Zhengzhou Winsen Electronics Technology Co., Ltd
www.winsen-sensor.com
Tel: 0086-371-67169097/67169670
Fax: 0086-371-60932988
Email: [email protected]
7. Anti-Interference
ME3-HF sensor also responds to other gases besides target gas. Below are the response characteristics of
interferential gases
Gas
Concentration
ME3-HF
CO
200ppm
0ppm
SO2
10ppm
≤1ppm
CL2
10ppm
≈5ppm
HCL
10ppm
≈10ppm
CHE
1000ppm
0ppm
CH3COOH
100ppm
100ppm
C2H5OH
1000ppm
0ppm
8. Application Notes
Sensor shall Avoid organic solvent, coatings, medicine, oil and high concentration gases;
All ME Sensors shall not be encapsulated completely by resin materials, and shall not immerse in
pure oxygen environment, otherwise, it will damage the function of sensor;
All ME sensors shall not be applied in corrosive gas environment, or the sensor will be damaged;
Please test the sensitivity of gas sensors in clean atmosphere;
Sensors Shall be avoided to face the gas, which flow directly from front side;
To avoid to bend and break of pins;