PURPOSE AND SAFETY 

Triton Dual is an electrical powered shower and toilet chair with the ability to position height 
and seat tilt. The chair is rated for 150 kg and can be used in homecare, nursing homes, 
institutions and hospitals. 

 

Purpose 

The purpose of Triton/Dual is to assist the user and caregiver in the daily personal hygiene 
activities. With the ability to adjust the height and seat tilt, Triton/Dual takes both the users 
comfort and the caregivers optimal working position into account. Activities that the chair 
can be used for could be: 

 

Toileting, either in bathroom or other suitable places with a bed pan.  

 

Showering or personal hygiene depending on the facilities available. 

The digital control box makes Triton/Dual a more user-friendly toilet/shower chair. With the 
four advance buttons on the hand control it allows the use a memory functions and a 
transport position which makes short transfers in the chair easier. 

Due to the LINAK components being rated 

IPx6W DURA™, 

Triton/Dual can be cleaned in a 

washing machine up to 250 times. The international standard only requires 50 washes, but 
with the high-quality components selected, this number is increased 5 times. 

After thorough cleaning Triton/Dual can be used by multiple users (See 4.1).  

Triton Dual is not a wheelchair and therefore not intended for longer transfers. Short 
transfers e.g. within a room or to and from the bathroom are allowed. 

Note: 

Do not use Triton Dual for purposes other than originally intended.  

 

Safety instructions 

Important - Warning!

 

Read user manual and safety instructions before using the product.

 

 

The maximum capacity of 150 kg must 

NEVER

 be exceeded. 

 

NEVER

 use the chair if there are suspicions of defects (abnormal sound, loose 

brackets etc.). In this case take the chair out of service and contact a service 
technician, your dealer or Winncare Nordic. 

 

NEVER

 leave the user alone in the chair 

 

NEVER

 lift higher than necessary. 

 

Always have the armrest folded down during use. If not possible for a given reason, 
be extra cautious about the user. 

 

The footrests should always be folded up before the user sits or stands up from the 
chair. 

 

Содержание Triton/Dual

Страница 1: ...nt information Read user manual before taking this product into use This user manual is intended as a guide for caregivers and other users as well as technical personnel during servicing and maintenan...

Страница 2: ...2...

Страница 3: ...10 DIRECTION LOCK ADD ON _______________________________________ 10 3 USING TRITON DUAL ___________________________________________ 11 USER TYPES _________________________________________________ 11...

Страница 4: ...ts being rated IPx6W DURA Triton Dual can be cleaned in a washing machine up to 250 times The international standard only requires 50 washes but with the high quality components selected this number i...

Страница 5: ...o and from the chair and whenever possible When using the chair with other equipment ensure that no dangerous situations can occur Keep an eye out for wires slings tubing etc Make sure that the chair...

Страница 6: ...iton Dual is to be transported between sites it is recommended to use the original packaging In case of return shipment of Triton Dual the original packaging must be used If unable to do so the user m...

Страница 7: ...s positioned between 7 and 0 the DOWN button will tilt the chair to 0 simultaneously 5 Transport position Lifts and tilts Triton Dual to a position recommended for making short transfers 6 Store Save...

Страница 8: ...ith a buzzer that will signal when it is about to run out of power LOW battery A constant warning signal is heard when any button on the hand control is pressed When the warning signal is heard the ch...

Страница 9: ...ergency stop and lowering 044 00051 With emergency stop and lowering The red emergency stop is located next to the control box Push to lock turn to reset The black emergency lowering button can be use...

Страница 10: ...plate can be adjusted by loosening the small screw with an Allen key Make sure to tighten the screw at the desired position Headrest Add on The head rest is height and depth adjustable The position ca...

Страница 11: ...in a position where the caregiver can assist the user in an ideal working position The seat tilt should be used to reach an ideal working position for the caregiver or to ensure the security and comf...

Страница 12: ...ashing procedure is followed Any other washing procedures may damage the chair Industrial high pressure cleaning is not allowed Winncare Nordic recommends that the actuators are positioned in their in...

Страница 13: ...eight adjustability works Easy to remove Emergency stop Not present on all models Works and releases again Lifting mechanism Actuator runs both ways Piston is lubricated Actuator is mounted correct Lo...

Страница 14: ...ressed Reset the emergency stop 0 Not present on all models Cables unplugged Check the cables going into the lifting and tilting actuator Remove the control box plastic cover and open the control box...

Страница 15: ...epth 430 mm g Height between armrest and seat 210 mm h Width between armrests 470 mm i Height to lower frame 150 mm j Height from seat to top of backrest 560 mm k Width of backrest 430 mm l Height of...

Страница 16: ...voltage 25 9VDC Max discharge current 10 A Control box input Charging 100 240 VAC 50 60 Hz 15 10 Control box Output 200 W Charging time First time 10 hours Charging time full 6 hours IP class IPx6W Fl...

Страница 17: ...nt if not handled in an environmentally responsible way Quality Winncare Nordic ApS is certified according to the quality standards ISO 9001 and ISO 13485 These certifications mean that the product an...

Страница 18: ...ating leg rest set 047 00361 047 00362 Amputation leg rest left Amputation leg rest right 047 10302 Wide armrest 047 10303 PUR Backrest 047 00904 Bedpan Light grey PP Compatible with factory mounted b...

Страница 19: ...100 w red brake screw 047 00608 Foot rest swiveling high adjustable 047 00705 Upholstery for armrest 047 10319 Flexible PU padding for adjustable head rest 047 10320 Small PU padding for headrest 047...

Страница 20: ...ufacturer Winncare Nordic ApS Taarnborgvej 12 C 4220 Korsoer Denmark Phone 45 70 27 37 20 Fax 45 70 27 37 19 Email info winncare dk www winncare dk 93 42 E F CLASS I EN ISO 10535 EN 60601 1 2 UM 910 0...

Отзывы: