User Guide
The last 2,000 locking transactions, so-called “events”, are stored in the
components. These events can be read out and displayed via the BXP. To do
this, the BXP is connected to the component. Selecting the menu item
“Reading out events” will automatically start the read-out process. After
successful read-out, conclusion of this process is confirmed.
Now you can view the events by choosing the item “Showing events”. The
display will then show a summary of the events that have been read out in
components lists. Select the requested components list. You can now view
the locking events of the chosen component. It is also possible to change
directly from the item menu “Reading out events” to the item “Showing
events”.
4.5 Reading out events / showing events:
Fig. 8: Cylinder list / showing events
As is the case with the components, you can also have the ID media (keys,
cards, key fobs) identfied and assigned. To this effect, please enter the key to
be identified into the BXP key slot. Cards and key fobs are placed on the
device.
The number of the ID medium as well as its period of validity are displayed.
4.6 Identifying ID medium:
Fig. 9: Identifying key