Wiring of Opening Devices
Day Night Function
Should during the day you not require the actuation of
the dead bolts, the lock can be switched so that
the dead bolts remain retracted.
To use this facility, you wire a simple single pole
rocker switch to terminals 9 & 10 of the
Terminal Block (Auxiliary Interface).
Push to open switch
This should be a spring return rocker switch and
should be wired to terminals 11 & 12 of the
Terminal Block (Auxiliary Interface).
Transponder Reader (Proximity)
This should be wired to terminals 15 & 16 of the
Terminal Block (Auxiliary Interface).
Sender Remote
This should be wired to terminals 13 & 14 of the
Terminal Block (Auxiliary Interface).