![Winix AZBU330-HWB Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/winix/azbu330-hwb/azbu330-hwb_user-manual_986732009.webp)
9
English
ZERO
REPLACING FILTERS
1. Removing Filters
Turn the unit power off before removing filters.
Reference steps 1-2 on page 5 (Installing Filters) to remove all filters.
Latch
Tabs
Pre-filter
①
Remove the front panel by grasping its upper edge and gently pulling
forward. Press on the Pre-filter tabs.
②
near the top of the filter, release and remove.
③
Pull out the Odor Absorbing Carbon filter and True HEPA filter.
2. Prepare New Filters
①
Remove filters from protective plastic
wrap.
ˍ
Operating the unit without removing
filters from plastic wrap may cause
abnormal noise, deformation, or fire
as a result of overheating.
NOTICE
ˍ
For optimal performance, only Winix filters should be used
with this unit.
3. Insert New Filters
Install the filters until they fit securely in place. Reference Step 4 on page 5 (Installing Filters).
Tabs
Pre-filter
Odor
Absorbing
Carbon filter
True HEPA
filter
Latch
①
Insert the True HEPA filter first, then the Odor Absorbing Carbon filter.
②
Insert the Pre-filter.
③
Put the front panel back on.
4. Resetting the Unit
①
After replacing the filters, turn the
power onto the unit and then use a thin
object, such as a paper clip, to press the
RESET switch for 5 seconds.
Содержание AZBU330-HWB