background image

WHERE TO USE

12~18 in

12~18 in

Allow 12 ~ 18 in. of space between TVs, radios, and other electronics

Electromagnetic interference from certain electronics may cause 

product malfunction.

Place indoors away from direct sunlight

Direct exposure may cause product malfunction or failure.

Only place on hard, flat surfaces

Flimsy or slanted surfaces may result in abnormal noise and 

vibrations.

Allow 12 ~ 18 in. from walls

For maximum air flow.

FRONT

BACK

PACKAGE CONTENTS

Smart Sensor

Air Outlet Vent

Power Plug

Control Panel

Front Panel

Unit

360º All-in-One 

True HEPA Filter

User

Manual

MODEL PART DIAGRAM

01
02

03

04

06

07

08

05

01. Filter Replacement Indicator

LED light indicates when it is time to change the 

filter.

02. Filter Reset Button

After replacing the 360º All-in-One True HEPA 

Filter, use a small object such as a paper clip, to 

press and hold the Filter Reset Button for at least 

5 seconds until the Filter Replacement Indicator 

turns off.

03. Auto Mode Button

The unit will default to Auto with PlasmaWave

®

 

enabled when first powered on.

 • Auto Mode automatically adjusts fan speeds 

according to your indoor air quality. The fan 

speed will adjust to low when air quality is good, 

medium when fair, and to high when poor.

04. Air Quality Indicator

Color coded LED light indicates one of three levels 

of Air Quality:  

Red (poor), Amber (fair), and Blue (good).

05. Sleep Mode Button

When Sleep Mode is activated, the Air Quality 

Indicator LED light is disabled.

 • Fan speed will automatically set to minimum 

speed (lower than 'Low') which will be nearly 

silent.

 • When Sleep Mode is active, PlasmaWave

®

 will be 

disabled, but it can be turned back on.

CONTROL PANEL

INITIAL OPERATION

1.  Turn the product upside down.
2.  Grab the handle at the bottom of the 

product, turn counter-clockwise, and pull 

out the filter cover.

3.  Remove the protective vinyl from the filter 

installed inside the product.

4.  Install the filter top side down into the 

bottom of unit until it is fully inserted. The 

top of the filter shows the opening and the 

bottom of the filter is solid.

5.  After installing the filter, turn the handle 

clockwise to close the filter cover.

6.  Return the product to an upright position 

and resume normal operation.

When to Replace Filters 

Filter

Indicator Light

When to Service

When to Replace

360º All-in-One  

True HEPA Filter

Clean once every 14 days

Lasts Approx. 12 months

 • When the Check Filter indicator LED is on, it is time to replace the All-in-One True HEPA Filter.

 • Intervals between filter replacement may vary depending on environment.

MAINTENANCE

O

1712-0110-00

FILTER

REPLACING FILTERS

Resetting Filter Life:

 

After replacing the 360º All-in-One True HEPA Filter, use a small object such as a 

paper clip, to press and hold the Filter Reset Button for at least 5 seconds until the 

Filter Replacement Indicator turns off.

CLEANING CARE

Cleaning the Filters:

Clean with a vacuum or a soft brush.

 • Only clean the Pre-Filter.

 • This filter CAN NOT be washed.

 • Intervals between filter cleaning may vary 

depending on the air quality.

Cleaning the Exterior & Interior:

Wipe with a soft damp cloth using room 

temperature water. Afterwards, wipe it down with 

a clean dry cloth.

After turning the product upside down, remove the 

filter cover and clean the interior with a vacuum 

cleaner.

 • For optimal performance, clean every 14 days.

  N O T I C E

 • When cleaning the unit, always unplug the power cord first and then wait until the unit has cooled 

down.

 • Never disassemble, repair, or modify this unit yourself.

 • Do not use flammable sprays or liquid detergents.

 • Do not allow children to clean or maintain the unit.

 • Before cleaning or maintaining, ensure unit is unplugged.

 • Do not use benzene, alcohol, or other volatile fluids, which may cause damage or discoloration.

06. PlasmaWave

®

 Button

Enables or disables PlasmaWave

®

"When the unit is running, you may hear a chirping 

or buzzing sound. The sound is from large 

particles passing through PlasmaWave

®

, it is 

normal and does not signify product failure."  

Press the PlasmaWave

®

 Technology button when 

the unit is on to enable or disable this feature.

07. Fan Speed Indicator Buttons

Indicates the current fan speed.

 • Use the Fan Speed arrow buttons to set the 

desired fan speed. Fan speeds cycle over in this 

sequence: Auto, Low, Medium, High, Auto.

Low Medium High

08. Power Button

Turns the unit on or off. During the first 30 

seconds of power, the Air Quality Indicator will 

cycle through Blue, Amber and Red colors.

 • Smart Sensor takes approximately 4 minutes to 

detect the air quality in the environment before 

normal operation begins.

UNIT SPECIFICATIONS

Model Name

A231 / A230

Dimensions

9.5 in(W) x 9.5 in(D) x 14.6 in(H)

Power Voltage

AC 120 V / 60 Hz

Weight

6.75 lbs

Power Rate

55 W

Replacement 

Filter

FILTER O/SKU: 1712-0110-00

Verified Room Size

230 sq.ft.

The exterior, design, and product specifications may be changed without prior notice to improve product performance.

Contact Winix for product related inquiries and customer service

 

Dedicated Call Center: 

 (877) 699-4649

 

Website: www.winixamerica.com

To expedite service, please specify the model name and number, the nature of the problem, 

your contact information, and your address.

4-STAGE  

AIR PURIFICATION

Activated Carbon Filter

Fine Mesh Pre-Filter

True HEPA Filter

PlasmaWave

Air Purification means it  

removes inanimate particles

Отзывы: