10.2.7
Malfunction of the air systems (XX40NN to XX44NN)
Tab 10-43 Scavenge air temperature in the receiver is too high
Indication
Possible cause
Procedure
TE4031-nnA
This is a result of the malfunction in
Table 10-4 - Supply pressure of the
cooling water to the SAC is too low
•
Do the repair shown there.
There is air in the cooling water
system
•
Release the unwanted air from the cooling
water system.
The SAC is dirty
•
Clean the SAC on the air side, refer to sec-
tion
9.5 Clean the scavenge air cooler dur-
.
The SAC is defective
•
Repair or replace the SAC.
Tab 10-44 Scavenge air temperature in the receiver is too low
Indication
Possible cause
Procedure
TE4031-nnA
This is a result of the malfunction in
Table 10-5 - Supply temperature of
the cooling water to the SAC is too
low
•
Do the repair shown there.
Tab 10-45 Scavenge air pressure is too high
Indication
Possible cause
Procedure
PT4043-nnC
A turbocharger surges
•
As a temporary procedure, decrease the en-
gine load.
•
If applicable, open the exhaust waste gate
valve.
•
Refer to the turbocharger manual.
A safety valve is defective
•
Repair or replace the defective safety valve.
Tab 10-46 Scavenge air pressure is too low
Indication
Possible cause
Procedure
PT4043-nnC
The silencer, SAC or water sepa-
rator is clogged
•
Remove the blockage and clean the item.
A turbocharger is defective
•
Refer to the turbocharger manual.
The auxiliary blowers do not oper-
ate at low load
•
Start or repair the auxiliary blowers.
X92-B
AA00-0000-00AAA-410C-A
Operation Manual
Malfunctions of systems and components
Winterthur Gas & Diesel Ltd.
- 332 -
Issue 002 2021-11
Содержание X92-B
Страница 8: ...X92 B Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 8 Issue 002 2021 11...
Страница 12: ...X92 B Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 12 Issue 002 2021 11...
Страница 113: ...X92 B Operation Manual Page left intentionally blank Winterthur Gas Diesel Ltd 113 Issue 002 2021 11...
Страница 241: ...7 Installation 7 1 Installation 242 X92 B Operation Manual Winterthur Gas Diesel Ltd 241 Issue 002 2021 11...