Tab 10-5
Supply temperature of the cooling water to the SAC is too low
Indication
Possible cause
Procedure
TE1371A
The cooling water supply system is
defective
•
Find the cause and repair the fault.
Tab 10-6
Temperature of the cooling water downstream of the SAC is too high
Indication
Possible cause
Procedure
TE1381-nnA
This is a result of the malfunction in
Table 10-4 - Supply pressure of the
cooling water to the SAC is too low
•
Do the repair shown there.
This is a result of the malfunction in
Table 10-5 - Supply temperature of
the cooling water to the SAC is too
low
•
Do the repair shown there.
X92-B
AA00-0000-00AAA-410C-A
Operation Manual
Malfunctions of systems and components
Winterthur Gas & Diesel Ltd.
- 322 -