Winegard Company • 3000 Kirkwood Street • Burlington, IA 52601-2000
90 DAY LIMITED WARRANTY
Winegard Company warrants this Winegard product against any defects in materials or workmanship within 90 (ninety)
days from date of purchase. No warranty claim will be honored unless at the time the claim is made, you present proof
of purchase to an authorized Winegard dealer (if unknown, please contact Winegard Company, 3000 Kirkwood Street,
Burlington, IA 52601-2000, Telephone 800-288-8094).
Winegard Company (at its option) will either repair or replace the defective product at no charge to you. This warranty covers
parts, but does not cover any costs incurred in removal, shipping or reinstallation of the product. This limited warranty does
not apply if the product is damaged, deteriorates, malfunctions or fails from: misuse, improper installation, abuse, neglect,
accident, tampering, modification of the product as originally manufactured by Winegard, usage not in accordance with
product instructions or acts of nature such as damage caused by wind, lightning, ice or corrosive environments such as
salt spray and acid rain.
The 90 Day Warranty is provided on the condition that the equipment is properly delivered with all handling and freight charges
prepaid to your Winegard dealer for return to our factory for repair or replacement. Winegard dealers will arrange for the
replacement or repair and return to you without charge the product which failed due to defective material or workmanship.
WINEGARD COMPANY WILL NOT ASSUME ANY LIABILITIES FOR ANY OTHER WARRANTIES, EXPRESS OR IMPLIED,
MADE BY ANY OTHER PERSON.
ALL OTHER WARRANTIES WHETHER EXPRESS, IMPLIED OR STATUTORY INCLUDING WARRANTIES OF FITNESS
FOR A PARTICULAR PURPOSE AND MERCHANTABILITY ARE LIMITED TO THE 90-DAY PERIOD OF THIS WARRANTY.
The foregoing shall be the sole and exclusive remedy of any person, whether in contract, tort or otherwise, and Winegard
shall not be liable for incidental or consequential damage or commercial loss, or from any other loss or damage except
as set forth above.
Some states do not allow limitations on how long an implied warranty lasts, or the exclusion of limitation of incidental or
consequential damages, so the above limitations or exclusions may not apply to you.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
Printed in U.S.A. © Winegard Company 2008 Rev4 01/21 2452439
Rev. 2/08
2452439
Rev4 01/21
FREE AT
Finding your favorite TV programming has
never been easier! Using your current
location, the app can help determine
the correct antenna positioning
to avoid obstructions with the
augmented reality (AR) view.
WINEGARD’S
HDTV TOWER FINDER APP
Register your product at
winegard.com/myantenna.
For help, email
[email protected]
LIGHTNING PROTECTION
FOR TV ANTENNA & SET
1) Mount the lightning arrestor or 75
ohm coaxial grounding block as close
as possible to where the 75 ohm
coaxial cable downlead enters the
house. See Figure at right.
2) The ground wires for both the mast
and the downlead should be copper
or aluminum wire, number eight or
larger. See at right.
3) The downlead wire from the antenna
to the lightning arrestor and the mast
ground wire should be secured to the
house, spaced from four to six feet
apart. See Figure at right.
WARNING:
Installation of this antenna near power
lines is dangerous! For your safety,
follow the installation instructions.
VHF/UHF Models YA7000C
and
YA7000D
VHF/UHF (HD) Antenna
INSTRUCTION MANUAL
NOTE:
Example of antenna grounding as per
National Electrical Code, ANSI/NFPA 70
Antenna Lead
In Wire
Ground
Clamp
Electric
Service
Equipment
Antenna
Discharge Unit
(NEC Section 810-20)
Power Service Grounding
Electrode System
(NEC Art 250, Part H)
Ground
Clamps
Grounding Conductors
(NEC Section 810-21)
NEC - National Electrical Code
Example of antenna grounding as per
National Electrical Code, ANSI/NFPA 70
(May substitute a 75 ohm
Coax Grounding Block)
Antenna Lead
In Wire
Ground
Clamp
Electric
Service
Equipment
Antenna Discharge Unit
(NEC Section 810-20).
May substitute a 75 ohm
coax grounding block
Ground Clamp
Power Service Grounding Electrode System
(NEC Art 250, Part H) – Nation Electrical Code
Grounding
Conductors (NEC
Section 810-21)
In the case of a “ground up” antenna installation, it may not be
necessary to ground the mast if the mast extends four or more feet into
the earth. Consult a TV serviceman for the proper depth in your location.
Matching Transformer
Element Sleeves (4)
End Cap (2)
Large Flange Nut (5)
Small Flange Nut (11)
Mast Clamp Insert (1)
U-Bolt (1)
Large Screw (1)
Small Screw (8)
Washer (4)
2 1/2" Bolt (1)
5/8" Bolt (2)
Low Band Short Element Extensions (2)
VHF Antenna Assembly
Low Band VHF Element Assembly
HARDWARE BAG CONTENTS
TOOLS REQUIRED (not included)
Flat Head Screwdriver
Phillips Screwdriver
Rubber Mallet
Crescent Wrench
or Pliers
Mounting Pipe
and Foot
PARTS LIST
ATTACHING THE COAX
Connect the 75 ohm coaxial cable to the matching transformer. The connection
should be finger tight.
The coaxial downlead may be secured to the mast with
tape or plastic wire ties.
Low Band Long Element Extensions (2)