background image

4

Cable Input

Set 2 

Output

Antenna

Downlead

AMPLIFIED MODELS ONLY

STEP 11: 

Select location for wall plate.  Run two 

coax cables (RG-6 type recommended) (three if set 2 

jack is going to be used) between locations and install 

connectors on each end. 

Mark cables so "cable 

input", "TV output" "Set 2" may be identified. 

Antenna downlead and +12 VDC will also be needed 

at inside wall plate/power supply location.

STEP 12:

  The wall plate/power supply assembly 

may be flush mounted in most standard electrical 

boxes. To flush mount cut a hole in wall to fit the box. 

Run 2  #12 wires between wall plate/power supply 

and +12 VDC source and route downlead cable to 

this location.

CAUTION 

THE POWER SUPPLY SHOULD BE TURNED OFF 

WHEN CONNECTING CABLES/WIRES TO POWER 

SUPPLY.  SEE FIGURE 14.
STEP 13: 

Make 12 volt connection to wall plate/

power supply, Figure 10. Install terminals on wires 

from +12 VDC source, Figure 11. Crimp terminals 

with appropriate crimping tool or equivalent, Figure 

12. Push wires onto tabs on terminal board as shown 

in Figure 10. If in doubt as to the polarity of the wires, 

connect them temporarily to tabs on circuit board and 

press ON switch on front of wall plate; if light comes 

on, polarity is correct, Figure 10.

STEP 14: 

Install connectors on downlead, set 2 and  

cable input cables as shown on page 6. Attach down-

lead cable to jack on wall plate/power supply marked 

antenna, Figure 13. Attach cable going to set 2 output 

to jack on power supply marked SET 2. Attach cable 

coming from cable input to jack on power supply 

marked CABLE.

STEP 15: 

Mount power supply in wall with screws 

provided and attach TV set cable to jack on front of 

power supply/wall plate.  Press ON switch on front of  

wall plate and check that light is on, Figure 14. 

CHECKING OPERATION OF POWER SUPPLY

 

1. Tune TV receiver to nearest station and rotate 

antenna for best picture and sound.
2. Press OFF switch on power supply. Picture on TV 

should be considerably degraded with power off.
3. 

This unit is equipped with a polyswitch

, (current 

limiting device), which will shut down +12 VDC if 

there is a direct short between antenna and power 

supply. Green indicator light will not light. Once short 

is eliminated, device will reset itself.
 

ADDING OPTIONAL AMPLIFIED WALLPLATE TO 

NON-AMPLIFIED RV/TV INSTALLATION

 

Model RA-7596 solid state TV signal amplifier works 

with any non-amplified RV/TV antenna. Improves 

picture quality. Uses +12 VDC; has on/off switch, 

indicator light, set 2 output, cable input and +12 VDC 

receptacle.

-12 VDC

(Ground)

FIGURE 12

FIGURE 13

FIGURE 14

WARNING

DO  NOT  connect  high 

current  devices  such 

as  hair  dryers  to  this 

receptacle.  Maximum 

current  rating  of  this 

receptacle is 8 amps at 

+12 VDC.

FIGURE 11

Connector

Ferrule

Crimp  Here

1/4" 

       #12 Wire  

 

Remove 1/4" of insulation 

from #12 wire.

Connector

Insulation

FIGURE 10

+12 VDC

Rev. 8/10

Содержание SENSAR III

Страница 1: ...red RV WING White RV GS WING Gray Residential Sensar only Sensar with Wingman VHF UHF VHF UHF Excellent Digital Reception Great Digital Reception Digital Reception Sensar vs Sensar with Wingman Channels 14 51 Channels 2 13 Channels 14 51 Channels 2 13 SENSAR III ANTENNA SENSAR III ANTENNA WITH WINGMAN ACCESSORY Printed in U S A Winegard Company 3000 Kirkwood Street Burlington Iowa 52601 2000 Wineg...

Страница 2: ...eration STEP 1 Choose location for antenna Figure 1 illustrates placement of the Sensar showing it in travel position You must be able to raise and rotate antenna without interfering with other roof mounted equipment Make sure inside ceiling area is clear to mount ceiling plate 3 10 Minimum Distance 3 10 To Nearest Obstruction STEP 5 Center elevating shaft in hole on roof Temporarily secure base p...

Страница 3: ...les in ceiling Mount ceiling plate with directional handle in place with screws provided Figure 9 STEP 10 Assemble directional handle spring nylon bearing directional handle decal and elevating crank as shown in exploded view in Figure 9 Remove backing from crank cover decal and press firmly inside directional handle Slide all parts over elevating shaft and install elevating crank so set screw is ...

Страница 4: ...tach down lead cable to jack on wall plate power supply marked antenna Figure 13 Attach cable going to set 2 output to jack on power supply marked SET 2 Attach cable coming from cable input to jack on power supply marked CABLE STEP 15 Mount power supply in wall with screws provided and attach TV set cable to jack on front of power supply wall plate Press ON switch on front of wall plate and check ...

Страница 5: ...ift part way up or down 5 Don t apply sealing compound or paint over top of base plate or anywhere on lift LUBRICATION Done 3 4 times annually STEP 1 To lubricate the elevating gear apply a liberal amount of silicone spray lubricant to the elevating gear with the lift in the down position see illustration Run the lift up and down to distribute the lubricant over gears STEP 2 Two times yearly or in...

Страница 6: ... and OFF watching for difference in picture quality If there is NO difference use following steps CAUTION The power supply should be turned OFF when connecting disconnecting cables to power supply and antenna but should be turned ON when testing for voltage 3 Disconnect cable from antenna and check for 12 VDC at Test Point 1 If there is 12 VDC the power supply is OK Replace antenna 4 If there is N...

Страница 7: ...BEFORE 1990 RP 4000 7 Worm Gear 12 25 Hex Elevating Shaft Assembly w Wave Washer Flat Washer O Ring Worm Gear Nut WHITE Directional Handle Ceiling Plate 4 Screws Spring Decal RP 6300 10 IVORY Directional Handle Ceiling Plate 4 Screws Spring Decal RP 6200 10 RW 2000 Roof Wedge 15 Interior Wedge 16 IW 5012 EK 1036 Directional Handle Extension 17 11 8 9 12 8 10 13 Flat Washer Wave Washer Rubber Quad ...

Страница 8: ...under warranty If the product is returned before the expiration of the warranty period Winegard Company will at its option either repair or replace the product This Limited Warranty does not apply if the product has been damaged deteriorates malfunctions or fails from improper installation misuse abuse neglect accident tampering modification of the product as originally manufactured by Winegard in...

Отзывы: