Example – Ampere-hour capacity: a battery with an ampere-hour capacity of 100 ampere-hours 

can deliver 

5 ampere for 20 hours before it is completely discharged. 

 

To determine the battery ampere-hour capacity: 

1)  Determine how many watts each piece of AC equipment (TV, light bulbs, etc) 

consumes. This can normally be found on the product label. If only the current draw is 

given, multiply the current draw by 115 to get the watt consumption. 

2)  Estimate the time (in hours) that each piece of equipment will be running between 

battery charging cycles. 

3)  Calculate the total watt-hours of energy consumption (power in Watts x operating time 

in hours) using the average power consumption and the total estimated running time (in 

hours). Power x Operating Time = Watt-Hours. 

4)  Divide the watt-hours by 10 to determine how many battery (12 volt) ampere-hours will 

be consumed. 

4.2 T

YPICAL 

P

OWER 

C

ONSUMPTION

 

Appliance

 

Watts

 

 

Appliance

 

Watts

 

Stereo 

200 

 

Microwave - 1000 W 

1000 

Table Fan 

200 

 

AC (5,000 BTU) 

700 

TV 

250 

 

Computer  

300 

Small Refrigerator 

350 

 

Hair Dryer  

1000 

Hand Drill - 1/2" 

600 

 

Coffee Maker  

1200 

Light Bulb - 100 W 

100 

 

Blender  

400 

4.3 W

IRE 

G

AUGE 

R

EFERENCE

 

4.3.1 

Ampacity Table 

  

Load Amperage – Power @ 12VDC

 

10A 

120W 

20A 

240W 

30A 

360W 

40A 

480W 

50A 

600W 

60A 

720W 

70A 

840W 

80A 

960W 

100A 

1200W 

120A 

1440W 

160A 

1920W 

200A 

2400W 

250A 

3000W 

C

ab

le

 L

en

gt

h (

fe

et

)

 

16AWG  16AWG  14AWG  12AWG  10AWG  8AWG  8AWG  6AWG  4AWG 

2AWG

 

2AWG

 

2/0AWG

 

3/0AWG

 

16AWG  16AWG  14AWG  12AWG  10AWG  8AWG  6AWG  6AWG  4AWG 

2AWG

 

1AWG

 

2/0AWG

 

4/0AWG

 

16AWG  14AWG  12AWG  10AWG  8AWG  6AWG  6AWG  4AWG  2AWG 

2AWG

 

1/0AWG

 

3/0AWG

 

4/0AWG

 

16AWG  14AWG  12AWG  10AWG  8AWG  6AWG  6AWG  4AWG  2AWG 

2AWG

 

1/0AWG

 

3/0AWG

 

4/0AWG

 

10 

16AWG  14AWG  12AWG  10AWG  8AWG  6AWG  6AWG  4AWG  2AWG 

2AWG

 

1/0AWG

 

3/0AWG

 

4/0AWG

 

12 

14AWG  14AWG  12AWG  10AWG  8AWG  6AWG  6AWG  4AWG  2AWG 

2AWG

 

1/0AWG

 

3/0AWG

 

4/0AWG

 

16 

14AWG  12AWG  12AWG  10AWG  8AWG  6AWG  6AWG 

4AWG

 

2AWG

 

2AWG

 

1/0AWG

 

3/0AWG

 

4/0AWG

 

20 

14AWG  12AWG  10AWG  8AWG  6AWG  6AWG 

4AWG

 

4AWG

 

2AWG

 

2AWG

 

2/0AWG

 

4/0AWG

 

4/0AWG

 

24 

12AWG  12AWG  10AWG  8AWG  6AWG 

4AWG

 

4AWG

 

2AWG

 

1AWG

 

1AWG

 

2/0AWG

 

4/0AWG

 

4/0AWG

 

28 

12AWG  10AWG  8AWG  8AWG 

6AWG

 

4AWG

 

4AWG

 

2AWG

 

1AWG

 

1AWG

 

2/0AWG

 

4/0AWG

 

4/0AWG

 

33 

10AWG  10AWG  8AWG  6AWG 

4AWG

 

4AWG

 

4AWG

 

2AWG

 

1AWG

 

1AWG

 

2/0AWG

 

4/0AWG

 

4/0AWG

 

42 

10AWG  8AWG  6AWG  6AWG 

4AWG

 

4AWG

 

2AWG

 

1AWG

 

1/0AWG

 

1/0AWG

 

3/0AWG

 

4/0AWG

 

NR

 

50 

8AWG  6AWG  6AWG  4AWG 

4AWG

 

2AWG

  2AWG 

1AWG

 

1/0AWG

 

1/0AWG

 

3/0AWG

 

NR

 

NR

 

NOTE: Applicable to conductors: Rated 0 through 2000 Volts with an a

mbient Temperature of 

30°C (86°F) 

Содержание VertaMax PIN-0500-12M

Страница 1: ...windynation VertaMax 500 Watt Power Inverter Series PIN 0500 12M Modified Sine Wave PIN 0500 12P Pure Sine Wave User s Manual...

Страница 2: ...2 2 Low Input Voltage 8 3 2 3 Power Overload 8 3 2 4 Over Heating 8 3 2 5 Short Circuit 9 3 2 6 Functional Matrix 9 3 2 1 Fuse Replacement 9 4 Application 9 4 1 Power Consumption 9 4 2 Typical Power C...

Страница 3: ...Inverter may be used for many different applications including Solar PV battery systems Wind Turbine battery systems Recreational Vehicles Boats etc Please read this manual carefully before installing...

Страница 4: ...use 1 3 SPECIFICATIONS 1 3 1 Electrical Specifications Parameter PIN 0500 12M PIN 0500 12P Continuous Rated Power 500 Watts Peak Surge Power 1000 Watts Input Voltage Nominal 12 13 VDC Input Voltage M...

Страница 5: ...using a copper wire to connect the grounding terminal on the VertaMax enclosure to earth ground or chassis ground The grounding terminal if applicable is located on the DC Input end of the inverter V...

Страница 6: ...stance connection For example if the power source is a battery the cable must be terminated with a battery terminal that clamps to the post on the battery IMPORTANT If there is an excessive voltage dr...

Страница 7: ...R The VertaMax features a Soft Start to handle the power surge that is created when some appliances are turned on This feature helps protect both the appliance and the inverter from excessive power dr...

Страница 8: ...is important to remove or shut down computers or other sensitive devices that may be connected to the VertaMax and recharge the battery before its capacity drops too low The inverter can operate while...

Страница 9: ...n No 12V DC input On Off Off Off 3 2 1 Fuse Replacement This inverter is equipped with two replaceable 30 amp internal fuses Never check or remove the fuses when the inverter is connected to a DC powe...

Страница 10: ...ulb 100 W 100 Blender 400 4 3 WIRE GAUGE REFERENCE 4 3 1 Ampacity Table Load Amperage Power 12VDC 10A 120W 20A 240W 30A 360W 40A 480W 50A 600W 60A 720W 70A 840W 80A 960W 100A 1200W 120A 1440W 160A 192...

Страница 11: ...e 100A h Battery Operating Time 100 watt 9 Amps 5 5 hours 11 hours 200 watt 19 Amps 2 6 hours 5 2 hours 500 watt 47 Amps 1 hour 2 hours All Values are approximate 4 4 2 Battery State of Charge SOC You...

Страница 12: ...ttery Amps Required Divide the total wattage required from step 1 above by the battery voltage 12 to determine the DC amps required STEP 3 Estimate Battery Amp Hours Required Multiply the DC amps requ...

Страница 13: ...oltage is too low Recharge battery Over load Reduce the load Battery run time is less than expected AC product s power consumption is higher than rated Use a larger battery to make up for increased po...

Страница 14: ...request within the Warranty Period by contacting Windy Nation in writing or via telephone and obtaining a Returned Materials Authorization RMA number This RMA must be obtained before returning any pro...

Страница 15: ...BY ANY PERSON 5 4 4 Limitation of Liability UNDER NO CIRCUMSTANCES WILL WINDY NATION OR ITS AFFILIATES OR SUPPLIERS BE LIABLE OR RESPONSIBLE FOR ANY LOSS OF USE INTERRUPTION OF BUSINESS LOST PROFITS...

Отзывы: