background image

VertaMax User Manual 

 

Revision 1.0 

 
 

1   INTRODUCTION 

The VertaMax Power Inverter is a highly reliable product that uses advanced technologies for high 
performance and stability. The VertaMax efficiently converts DC power from your vehicle, boat, or directly 
from a dedicated 12V DC battery, into 120V AC power that is commonly used in a wide variety of household 
AC items, such as computers, mobile phone chargers, radio, TV etc. 
 
The VertaMax works in two stages: During the first stage, the DC to DC converter increases the DC input 
voltage from the power source (e.g. 12V battery) to 300VDC. In the second stage, this high voltage DC is 
converted into a modified sine wave AC output using advanced power MOSFET transistors or IGBT 
technology in a full bridge configuration. The result is excellent overload protection and capacity to operate 
different reactive loads. 
 
The Inverter may be used for many different applications including Solar (PV) battery systems, Wind Turbine 
battery systems, Recreational Vehicles, Boats, etc. 
 
Please read this manual carefully before installing or using the inverter and keep it for future reference. 

1.1  F

EATURES

 

9

  Microprocessor Based PWM (Pulse Width Modulation) Operation 

9

  Three AC Receptacles 

9

  Soft Start 

9

  Power On/OFF Switch and LED indicator 

9

  Remote On/Off Capability 

9

  Voltage and Power Meter 

9

  Automatic Overload Protection 

9

  Low Voltage Shutdown Battery Protection 

9

  Short Circuit Protection 

9

  High Temperature Protection 

9

  Fused Reverse Polarity Protection 

 

 

 

Fault LED 

AC Outlets [x3] 

Power LED 

Digital Display Meter 

ON/OFF Switch 

DC Positive (+) Input [x2] 

USB Outlet* 

Cooling Fan 

Grounding Terminal 

10 

DC Negative (-) Input [x2] 

*

 If covered, the port is not functional and should not be used 

 

 

windy

nation

 

Page 3 of 16 

 

 
 

Содержание PIN-1500-12

Страница 1: ...windynation VertaMax Power Inverter PIN 1500 12 PIN 2500 12 User s Manual...

Страница 2: ...Voltage 8 3 4 2 Low Input Voltage 9 3 4 3 Power Overload 9 3 4 4 Over Heating 9 3 4 5 Short Circuit 9 3 4 6 Functional Matrix 9 4 Application 9 4 1 Power Consumption 9 4 2 Typical Power Consumption 1...

Страница 3: ...excellent overload protection and capacity to operate different reactive loads The Inverter may be used for many different applications including Solar PV battery systems Wind Turbine battery systems...

Страница 4: ...inal 120VAC 120VAC USB Output Voltage 5VDC 5VDC Output Frequency Nominal 60 Hz 60 Hz Output Waveform Modified Sine Wave Modified Sine Wave 1 3 2 Physical Specifications Parameter Value Dimension H x W...

Страница 5: ...GFPD The system electrical negative should be bonded through a GFPD to earth ground at one and only one location The grounding point may be located in the solar wind circuit or the battery circuit 2 4...

Страница 6: ...the cable must be terminated with a battery terminal that clamps to the post on the battery IMPORTANT If there is an excessive voltage drop and the voltage at the inverter drops below 10 volts the in...

Страница 7: ...ome appliances are turned on This feature helps protect both the appliance and the inverter from excessive power draws and surges When the power switch is turned on the VertaMax Soft Start will smooth...

Страница 8: ...indicator will work as normal operation and will light when the VertaMax is remotely ON 3 2 USB PORT The USB outlet if equipped will supply 5 volts at 500ma to charge and power cell phones MP3 Players...

Страница 9: ...e manual power switch 3 4 4 Over Heating When the inverter exceeds a safe operating temperature due to insufficient ventilation or an increase of ambient temperature the inverter will automatically sh...

Страница 10: ...TION Appliance Watts Appliance Watts Stereo 200 Microwave 1000 W 1000 Table Fan 200 AC 5 000 BTU 700 TV VCR 250 Computer 300 Small Refrigerator 350 Hair Dryer 1000 Hand Drill 1 2 600 Coffee Maker 1200...

Страница 11: ...e power inverter will also draw a small current less than 600mA when turned off and not operating Therefore it should be disconnected from your battery if it will not be used for more than a day The f...

Страница 12: ...EP 3 Estimate Battery Amp Hours Required Multiply the DC amps required from step 2 above by the number of hours you estimate you will operate your equipment exclusively from battery power before you h...

Страница 13: ...operates for a short period and then turns off Load is trying to draw too much current Be sure load is less than rated watts of inverter Remove excessive load Turn inverter off and back on to reset Al...

Страница 14: ...sole and exclusive remedy and the entire liability of Windy Nation its suppliers and affiliates for breach of the warranty is at Windy Nation s option either i to replace the Product or defective com...

Страница 15: ...L WARRANTIES EXPRESS IMPLIED AND STATUTORY INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO ANY PRODUCTS PROVIDED BY WINDY NA...

Страница 16: ...l causes of action and all theories of liability will be limited to and will not exceed the purchase price of the Product paid by Customer This warranty gives the Customer specific legal rights and th...

Отзывы: