3.2  LED

 

I

NDICATORS

 

 

 

LED 

State

 

Description

 

OFF 

No Charge (Nighttime) 

Solid Green 

Solar power is charging the battery 

Charge 

Blinking Green 

The system is over voltage 

Solid Green 

Battery level is in the right range 

Slow Flash Green  Battery level is full 

Solid Yellow 

Battery level is low 

Battery 

Solid Red 

Load cut-off 

Solid Red 

The output is on 

Slow Flash Red 

Overload 

Load 

Blinking Red 

Load is short circuit 

 

Note: The load output will shut off once there is an overload or short circuit. Disconnect all of the equipment 
and then wait a few seconds before reconnecting everything. Press the Power/Mode button and the 
controller will resume working after approximately 10 seconds, or in some instances, it may take a few 
moments longer. 

3.2.1 

Charge LED 

When the connected solar panel is exposed to sunlight, the Charge LED will be green, indicating that the 
system is charging normally. 
The Charge LED will flash green when an overcharge condition or an open battery circuit exists. 
PWM mode is used during charging. If an over-discharge of the battery has occurred, the charger will switch 
to boost voltage for 10 minutes, then will return to direct voltage for at least 10 minutes to activate the 
battery, and finally to the float voltage state where it will remain to maintain the best state of the battery. This 
multistep charging process will help bring the battery to full charge and maximize its life span. 

3.2.2 

Battery LED 

The Battery LED is green when the battery voltage is in normal condition. It will blink green slowly when the 
battery finishes its charge. 
 
The LED is yellow when the voltage of the battery is below normal. 
 

Содержание CHC-1224-10

Страница 1: ...CHC 1224 xx User Manual Revision 1 0 Page 1 of 1 windynation 07 19 2013 windynation Solar Panel Charge Controller CHC 1224 10 CHC 1224 30 User s Manual...

Страница 2: ...2 LED Indicators 7 3 2 1 Charge LED 7 3 2 2 Battery LED 7 3 2 3 Load LED 8 3 3 Setting Modes 8 3 3 1 Normal Control 8 3 3 2 Night ON Day OFF Control Mode 8 3 3 3 Night ON Set Time Delay OFF Mode 8 3...

Страница 3: ...load event the system will be protected and remain undamaged The enclosure is made of durable plastic with LED lights to provide status indications of charge battery status and system faults as well a...

Страница 4: ...29 6V Overcharge Recovery 13 2V 26 4 V Over discharge Disconnection 11 1V 22 2V Over discharge Reconnection 12 5V 25 0V Temperature Compensation 4 0 mV o C 2V 1 4 2 Physical Specifications Parameter V...

Страница 5: ...mounting surface 3 Tighten all the fasteners to ensure the controller cannot slide in any direction IMPORTANT For best results mount the charge controller and batteries as close to the panels as pract...

Страница 6: ...avoid touching any conductors in the system circuit to avoid electric shock 3 Connect the Load Optional If you have a 12VDC application connect the wires from the appliance to the load port on the ch...

Страница 7: ...or in some instances it may take a few moments longer 3 2 1 Charge LED When the connected solar panel is exposed to sunlight the Charge LED will be green indicating that the system is charging normal...

Страница 8: ...ay begins to flash 5 seconds Press the button repeatedly to choose the desired mode number When the desired number is selected stop pressing the button and wait for number to stop flashing indicating...

Страница 9: ...1 Night ON 2 Hours delay OFF 02 Night ON 12 Hours delay OFF 12 or 2 Night ON 3 Hours delay OFF 03 Night ON 13 Hours delay OFF 13 or 3 Night ON 4 Hours delay OFF 04 Night ON 14 Hours delay OFF 14 or 4...

Страница 10: ...PV voltage is within specifications to the open circuit voltage rating of the panels but the battery voltage is low the charge controller may not be charging the battery and it may be damaged The cha...

Страница 11: ...t submit a service request within the Warranty Period by contacting Windy Nation in writing or via telephone and obtaining a Returned Materials Authorization RMA number This RMA must be obtained befor...

Страница 12: ...ERSON 5 4 4 Limitation of Liability UNDER NO CIRCUMSTANCES WILL WINDY NATION OR ITS AFFILIATES OR SUPPLIERS BE LIABLE OR RESPONSIBLE FOR ANY LOSS OF USE INTERRUPTION OF BUSINESS LOST PROFITS LOST DATA...

Отзывы: