background image

BattaMax User Manual  

Revision 3.0

 

 

Page 12 of 13 

windy

nation

 

10/04/2019 

 

Measure the individual battery voltages and remove any battery with a voltage that is greater than 0.3V 

compared to other batteries in set (e.g. battery bank). 

6.2  D

ISCHARGE 

 

C

APACITY

 

1.  Connect a load or discharger to battery and start the discharge process. 

2.  Record the runtime (minutes) until the discharge is complete. 

3.  Normalize the runtime minutes for temperature using the following formula: Rc = Ra [1 – 0.004 (Bt - 80)] 

i.  Rc = Runtime Corrected 

ii.  Ra = Actual discharge time 

iii.  Bt = Battery temperature at end of discharge (°F) 

If the discharge runtime is greater than 50% of the batteries’ rated capacity at that discharge rate, then all the 

batteries are operational. 

4.  Restart the discharger to record the individual battery voltage while still under load (current being 

drawn). 

If the discharge runtime is less than 50% of the batteries’ rated capacity, the battery with a voltage that is 0.5V 

lower than the highest voltage may be a failed battery. 

6.3  S

UPPORT

 

If you are experiencing technical problems, and cannot find a solution in this manual, you can contact Windy 

Nation Inc. for further assistance. 

  Call: (805) 323-6445 

  Email: 

[email protected]

 

  Write: 1404 Fleet Ave., Ventura, CA 93003 

 

For challenging issues or to just ask a question, consider using our FREE Community Forums! Consult our 

community of DIY'ers for fast answers to all your questions. 

 

Post on our Forums: 

Windy Nation Community Forum 

6.4  L

IMITED 

W

ARRANTY

 

Windy Nation warrants that the Battery (the “Product”), will be free from manufacturing defects in materials and 
workmanship under normal authorized use consistent with product instructions for a period of one (1) year from 
the date the original purchaser (“Customer”) receives the Product (the “Warranty Period”). This warranty 
extends only to the original purchaser. The Customer’s sole and exclusive remedy and the entire liability of 
Windy Nation, its suppliers and affiliates for breach of the warranty is, at Windy Nation’s option, either (i) to 
replace the Product (or defective component part(s)) with a new or reconditioned Product (or component 
part(s)); (ii) to repair the reported problem; or (iii) to refund the purchase price of the Product. Repaired or 
replaced products are warranted for the remainder of the original warranty period only. No employee, agent, 
dealer or other person is authorized to give any warranties on behalf of Windy Nation not expressly set forth in 
this limited warranty. 

6.5  R

ESTRICTIONS

 

No warranty will apply if the Product (i) has been altered or modified except by Windy Nation; (ii) has not been 
installed, operated, repaired, or maintained in accordance with instructions supplied by Windy Nation; (iii) has 
been subjected to abnormal physical, thermal or electrical stress, misuse, negligence, or accident. If Windy 
Nation determines that the problem with the Product is not due to a manufacturing defect in Windy Nation’s 
workmanship or materials, or otherwise does not qualify for warranty repair, then the Customer will be 
responsible for the costs of all necessary repairs and expenses incurred by Windy Nation. 

6.6  W

ARRANTY 

C

LAIMS 

&

 

R

ETURN 

P

ROCEDURES

 

To be eligible for service under this warranty, the Customer must submit a service request within the Warranty 
Period by contacting Windy Nation in writing or via telephone and obtaining a Returned Materials Authorization 
(“RMA”) number. This RMA must be obtained before returning any product under this warranty.  Notification 
must include a description of the alleged defect, the manner in which the Product was used, the serial number, 

Содержание BattaMax BAT-RA12-033

Страница 1: ...BattaMax User Manual Revision 3 0 Page 1 of 13 windynation 10 04 2019 BattaMax Absorbent Glass Mat AGM Sealed Lead Acid SLA Batteries BAT RA12 033 BAT RA12 100 User s Manual...

Страница 2: ...ies Parallel Connection 7 4 Service and Maintenance 8 4 1 Charging 8 4 1 1 State of Charge SOC 8 4 1 2 Charge Characteristic Curve Standby Use 9 4 1 3 Temperature Compensation 9 4 2 Discharging 9 4 2...

Страница 3: ...nd servicing should be referred to qualified service personnel Remove all sources of power photovoltaic wind generator battery chargers etc before servicing or installing Battery Safety Warning Batter...

Страница 4: ...0hr 1 80V cell 25oC 35 Ah 106 Ah Nominal Capacity 10hr 1 80V cell 25oC 33 Ah 100 Ah Max Discharge Current 330A 5S 1000A 5S Internal Resistance 10 0m 5 0m Cycle Use 14 6 14 8V 25oC Temp Coefficient 4mV...

Страница 5: ...ures there is more chemical activity inside a battery than at lower temperatures The following chart shows the temperature effects to the battery capacity The following chart shows the temperature eff...

Страница 6: ...rminals and comes with the necessary bolts and washers to secure a cable connection Place battery connection cable lug not included over the threaded insert of the battery terminal ensuring that the c...

Страница 7: ...stem capacity Ah and the system voltage will remain unchanged For example if two 12V batteries with 50Ah of capacity are wired in series the resulting battery bank will be 12V of 100Ah 50Ah 50Ah 100Ah...

Страница 8: ...hat higher charge voltage to charge the battery quickly and safely Once the battery is fully charged a somewhat lower voltage is applied to maintain the battery in a fully charged state Important Batt...

Страница 9: ...y temperature The temperature should be adjusted by subtracting 0 004 volt per cell from the voltage reading for every 1 C above 25 C or adding 0 004 volt per cell for every 1 C below 25 C 4 2 DISCHAR...

Страница 10: ...5 36 0 6 68 20 9 3 50 10 8 1 65V cell 131 9 405 4 103 8 316 7 63 7 190 1 36 8 117 1 22 1 71 1 17 3 52 7 11 7 36 5 6 77 21 1 3 53 10 9 1 60V cell 136 9 407 0 107 0 318 5 65 6 191 5 37 9 118 0 22 8 71 7...

Страница 11: ...inter months it is critical that they are kept fully charged at all times 5 2 RECYCLING Batteries that have reached the end of their service life should be returned to a local or regional collection c...

Страница 12: ...e 1 year from the date the original purchaser Customer receives the Product the Warranty Period This warranty extends only to the original purchaser The Customer s sole and exclusive remedy and the en...

Страница 13: ...RPOSE WITH RESPECT TO ANY PRODUCTS PROVIDED BY WINDY NATION NO ORAL OR WRITTEN INFORMATION OR ADVICE GIVEN BY WINDY NATION ITS DEALERS DISTRIBUTORS AGENTS OR EMPLOYEES SHALL IN ANY WAY INCREASE THE SC...

Отзывы: