background image

4. Screw the four 1" wood screws (for

mounting the hood) into the exact

center of the arrow and of the keyhole

mounting slots marked on the cabinet

bottom (for flush installations), or

marked on the 1”

recessed cabinet installation) (Fig.7)

Do not turn the mounting screws in all

the way. Allow 3/8" of screw to project,

so the hood can be fitted place.

(The screws will be tightened later)

x2” wood strips (for

If drilling into the walls, be careful not to cut existing electrical cables,

which would create a hazard.

Fig.9

Fig.8

1. After turning off the proper 120 volt circuit at the service entrance,

drill out the electrical power line access hole marked on the cabinet

bottom or wall. Use a 1

”wood bit. To operate the electric drill, use

an extension cord connected to another circuit. (Fig.8)

¼

Note: Please also refer P.10 "J. Making the Electrical Connection"

Color:
green/white/black

Connecter

1

" bit

Fig.7

G. Providing Electrical Power

7

Safety Warning:

2. Fish the electrical power line through the access hole drilled in the wall or

bottom of the cabinet. Attach an appropriate connector (purchased locally)

to the end of the power line for the type of wiring being installed. Follow all

codes. (Fig.9)

Strips secured

G. PROVIDING ELECTRICAL POWER

Содержание WS-58 series

Страница 1: ...ERATION Please read and save this guide through before using your range hood Store the guide away in a safe place so that you will know where it is when you want to refer to it MODEL WS 58 series MANU...

Страница 2: ...Making The Electrical Connection Use and Care Maintenance Instruction Ducting Troubleshootings Parts Layout Diagram Circuit Diagram Size Replace The LED Light P 1 P 3 P 4 P 4 P 5 P 6 P 7 P 8 P 8 P 9...

Страница 3: ...cannot blocked securely fasten prominent warning device such as a tag to service panel TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY OBSERVE THE FOLLOWING CAUTION For general ventilating use on...

Страница 4: ...ur back to an exit USE AN EXTINGUISHER ONLY IF CLASS ABC C including wet dishcloths or towels a violent steam explosion will result DO NOT USE WATER B You may be burned NEVER PICK UP A FLAMING PAN WAR...

Страница 5: ...e electric shock or injury for cleaning or maintenance such as lubrication 4 Fireplaces gas furnaces water heaters require proper flow of combustion air and exhaust Make sure this flow is not altered...

Страница 6: ...tallation only Purchase locally Electrical wire and supplies to comply with local cords Four 1 long flat head wood screws purchase locally to mount wood strips Pencil and ruler for marking locations S...

Страница 7: ...er into the knockout slot and bend the knockout back and forth Fig 2 3 You may have to use pliers to pull the loosened knockout free Fig 3 4 When installed the bottom edge of your range hood should be...

Страница 8: ...1 long wood screw purchased locally about 3 from each end of the 1 x2 wood strips Fig 6 c Position the strips on the cabinet bottom and screw the strips securely to the cabinet Fig 7 d For a more sec...

Страница 9: ...8 1 After turning off the proper 120 volt circuit at the service entrance drill out the electrical power line access hole marked on the cabinet bottom or wall Use a 1 wood bit To operate the electric...

Страница 10: ...kout opening 8 Fig 10 Fig 11 Fig 11 Before changing LED light ensure the unit is pressed the main power button off when you want to change the LED light please always wear working gloves 1 Using suita...

Страница 11: ...nd install screw 2 Remove the hood from the board and nail the wood board onto the wall Be sure the nail is in the center of the stud 3 Place the range hood on the board and tighten the screw Bracket...

Страница 12: ...After connection is done reinstall wiring case cover and bottom board 5 Slide plastic collection cups onto the back metal mounting 6 Turn on power and check operation of fan and light 10 Fig 12 wire c...

Страница 13: ...d can be interchanged by pressing any one of above 3 buttons however b NEVER PRESS ANY OF TWO BUTTONS IN A TIME 3 NOTE A Press to turn on the LED light B Press again tor turn off the LED light Use for...

Страница 14: ...rayer is not included 2 Leave fan on for an additional 3 minutes to dry oil basin 3 Repeat on other turbine vane can be cleaned simultaneously with the first 2 After using the machine wipes the machin...

Страница 15: ...INGS This style of range must be vented via ducting to the outside of the house Follow general rules when ducting the hood Use correct size of ducting 6 or 7 round do not reduce size of ducting make a...

Страница 16: ...Q Parts Layout Diagram 14 Q PARTS LAYOUT DIAGRAM 1 3 2 5 6 7 8 14 15 16 17 18 19 20 4 30 2pcs 10 36 3pcs 42 3pcs 48 4pcs 11 12 13 9...

Страница 17: ...button Capacitor LED driver Bracket Wiring partition No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 With asterisk on 36 42 48 quantity may be varied Per hood 1 1 1 1 2 2 2 2 2 2 1 1 1 2 1 1 1 1...

Страница 18: ...qualified technician R Circuit Diagram 16 Voltage 120V 60Hz Power consumption maxi 170W Motor LED light R CIRCUIT DIAGRAM MOTOR OFF MOTOR MOTOR POWER CORD Capacitor WHITE WHITE WHITE YELLOW YELLOW WHI...

Страница 19: ...S Size 17 S SIZE 30 36 42 6 1 2 30 36 42 21 7 8 20 7 8 6 1 2 32 87 15...

Страница 20: ...warrants this product against defects in material or workmanship as follows 1 Labor For a period of one 1 year from the date of purchase if this product is determined to be defective Windster will re...

Страница 21: ...product arrival to obtain a Return Merchandise Authorization RMA Returns sent without a RMA will not be accepted There will be a 25 re stocking fee for every returned items Shipping fee will also be...

Отзывы: