![Windsor MB1500 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/windsor/mb1500/mb1500_operating-instructions-manual_985619014.webp)
MACHINE TROUBLESHOOTING
MB1500 98804 10/02/00
4-1
PROBLEM
CAUSE
SOLUTION
Machine will not run
Circuit breaker tripped in
building.
Check and reset
Power switch failure
Test switch for continuity
and replace if necessary.
Tripped circuit breaker
Reset
Faulty power cord
Replace
Fuse in motor is blown
Replace
CAUTION: To reduce the
risk of electrical shock,
unplug the machine before
opening fuse holder.
Fuse will only open under
extreme conditions.
Investigate cause before
replacing.
Electrical shock
Equipment not grounded
Follow grounding
instructions exactly.
Receptacle not grounded
Have an electrician inspect
building’s wiring.
Internal wiring problem
Ensure that the machine
wiring matches the
appropriate wiring
diagram. Replace any
wires or components which
are short circuiting.
Repeated cuicuit breaker tripping
Mechanical problem
Higher amp draws indicate
a mechanical problem, find
the problem before using
the machine.
Faulty circuit breaker
Test circuit for continuity.
Replace circuit breaker if
necessary.
Excessive vibration
Pad not centered
Re-center pad.
Damaged or unevenly worn
pad.
Replace pad. Do not rest
machine on pad when not
in use.
Damaged pad driver.
Replace.
Pad does not turn but motor is
running
Belt is loose or broken
Adjust or replace belt
Содержание MB1500
Страница 2: ...MB1500 98804 05 19 00 1 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 13: ...MB1500 98804 01 24 02 3 5 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 16: ...MOTOR GROUP MB1500 98804 09 28 00 5 1 1 2 3 4 ...
Страница 18: ...FRAME GROUP MB1500 98804 09 28 00 5 3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 8 15 16 ...
Страница 20: ...DRIVE PAD LOCK GROUP MB1500 98804 09 25 00 5 5 8 14 19 20 9 15 16 17 18 7 6 5 4 3 2 1 11 11 12 13 10 ...
Страница 24: ...WIRING GROUP MB1500 98804 09 25 00 5 9 11 6 2 1 3 4 5 10 7 9 8 9 8 ...