MACHINE TROUBLESHOOTING
LB2000 980088 03/08/03
4-1
PROBLEM
CAUSE
SOLUTION
Machine will not run
Tripped circuit breaker
Reset
Circuit breaker tripped in
building.
Check and reset
Fuse in motor is blown
Replace
CAUTION: To reduce the risk
of electrical shock, unplug the
machine before opening fuse
holder.
Fuse will only open under
extreme conditions.
Investigate cause before
replacing.
Power switch failure
Test switch for continuity and
replace if necessary.
Faulty power cord
Replace
Equipment not grounded
Follow grounding instructions
exactly.
Receptacle not grounded
Have an electrician inspect
building’s wiring.
Electrical shock
Internal wiring problem
Ensure that the machine
wiring matches the
appropriate wiring diagram.
Replace any wires or
components which are short
circuiting.
Mechanical problem
Higher amp draws indicate a
mechanical problem, find the
problem before using the
machine.
Repeated circuit breaker tripping
Faulty circuit breaker
Test circuit for continuity.
Replace circuit breaker if
necessary.
Pad not centered
Re-center pad.
Damaged or unevenly worn
pad.
Replace pad. Do not rest
machine on pad when not in
use.
Excessive vibration
Damaged pad driver.
Replace.
Содержание LB2000
Страница 13: ...LB2000 980088 03 08 03 4 3 THIS PAGE LEFT BLANK INTENTIONALLY ...
Страница 14: ...DECK GROUP LB2000 980088 03 08 03 5 1 16 8 11 13 14 15 12 9 10 6 7 1 4 5 3 2 ...
Страница 16: ...HANDLE GROUP LB2000 980088 03 08 03 5 3 16 17 1 2 3 4 5 6 10 7 9 8 11 15 14 13 12 ...
Страница 20: ...MOTOR GROUP LB2000 980088 03 08 03 5 7 1 2 3 ...
Страница 22: ...PAD DRIVER GROUP LB2000 980088 03 08 03 5 9 10 2 9 8 6 5 7 3 1 2 11 4 12 ...
Страница 24: ...WIRING GROUP LB2000 980088 11 15 03 5 11 11 8 9 6 2 1 3 4 10 9 8 5 7 12 PRIOR TO SN ...