Please carefully unpack and inspect your machine 

for shipping damage. Each unit is operated and thor- 
oughly inspected before shipment, and any damage is 
the responsibility of the delivering carrier who should 

be notified immediately. 

ELECTRICAL 

This rotary polisher is designed to operate on a standard 15 

amp, 

115 

volt, 

60 

hz, 

AC household 

Check that the 

voltage shown on the serial number plate is suitable for the 
supply available. Voltages below 105 volts or above 

125 

volts 

could cause damage to the motor. 

NOTE: 

volt 

50 

models 

are available. 

GROUNDING INSTRUCTIONS 

This appliance must be grounded.  If it should malfunc- 
tion or break down, grounding provides a path of least 

resistance for electric current to reduce the risk of elec- 

tric shock.  This appliance is equipped with a cord hav- 

ing an equipment-grounding conductor and grounding 
plug. The plug must be inserted into an appropriate out- 
let that  is  properly installed and  grounded  in accor- 

dance with all local codes and ordinances. 

WARN NG 

Improper connection of the equipment-grounding 
conductor  can  result in 

risk of  electric shock. 

Check with a qualified electrician or service person 
if 

you are in doubt as 

to 

whether  the outlet 

is 

prop- 

erly grounded. 

Do 

not modify the plug provided 

with the appliance 

if 

it will not 

the outlet, have 

a proper outlet installed by 

qualified electrician. 

This appliance is for use on a nominal 120-volt circuit, 
and has a grounded plug that looks like the plug in “Fig. 

below. 

temporary adaptor that looks like the adap- 

tor in “Fig 

below 

may be used to connect this plug 

to 

2-pole receptacle as shown in “Fig.  B  below, if a 

properly grounded outlet is not available.  The tempo- 
rary  adaptor  should  be  used  only  until  a  properly 
grounded outlet (Fig. A) can be installed by a qualified 
electrician. The green colored rigid ear, lug, 

or  the like 

extending from the adaptor must be connected to a per- 
manent ground such as a properly grounded outlet box 
cover.  Whenever the adaptor 

is 

used, it must be held 

in place by a metal screw. 

PROPER GROUNDING 

CONNECTION 

CONNECTION 

USING 

AN 

ADAPTOR 

GROUNDING 

Grounding Pin 

\ \  

I-  

Screw 

Grounded 

Outlet 

Tab 

For Groundina 

Screw 

Grounded Outlet 

Box 

ADAPTOR 

flg. 

NOTE:  Adaptors 

are 

not allowed In Canada. 

Fig. 

CAUTION: For indoor 

U s e  

Only. 

To prevent 

damage to the floor 

when using the Brush optlon, use water or other 
approved 

solution 

operating. 

When using the pad optloln, always keep 

the machine moving when In contact with the 

WARNING: 

HIGH 

TORQUE. 

HOLD MACHINE FIRMLY 

BOTH 

HANDS. 

.) 

Ensure that the pad driver 

or 

brush is installed correct- 

ly  and in good shape.  Install or change pad if necessary 

(See Page 3 

for 

of 

Installation). 

2.) 

Plug the machine into a wall outlet 

as 

described in the 

grounding instructions. 

3.) 

Lower the handle 

by unlocking the adjustment handle 

and moving the handle into position. 

the handle 

when it is in a comfortable position. 

4.) 

Check to be sure the pad driver or brush is installed 

before starting. 

5.) 

With the switch 

rotated forward, squeeze one 

of the switch levers, turning the machine on.  (These levers 
can be operated independently 

of each other) 

6.) 

To 

stop the  machine, release the  switch  lever 

and 

switch lock. 

NOTE 

The machine is equipped with a circuit breaker 

to 

protect the motor in the event 

an 

overload condition 

occurs.  The circuit breaker is located 

at 

the bottom of the 

switch housing.  Push the reset button to restart the ma- 
chine.  If the breaker trips again, correct the cause of over- 
loading before proceeding. 

7.) 

Do not let machine rest on pad. When finished with the 

machine for the day return handle to the storage position. 
Be sure to leave machine in a 

safe 

place where there is no 

risk of being tipped over. 

CONTROLS 

Page 

Содержание L175

Страница 1: ...TE WARNING OF APOTENTIAL INJURY This product contains moving parts To reducethe risk of injury unplug the machine beforeservicing Whenever repairsare madeensureelectrical connections are correct and w...

Страница 2: ...can be installedby a qualified electrician The greencoloredrigidear lug or the like extendingfromthe adaptormustbeconnectedto aper manentgroundsuchas aproperlygroundedoutlet box cover Wheneverthe ada...

Страница 3: ...or lug and rotate clockwise until engaged To remove turn Counter MOTOR GEAR UNITASSEMBLY 1 2 Remove 4 bolts holdinghandle bracket aside Lift offplasticmotor shroud Tip machineback andremove 4 bolts ho...

Страница 4: ...4 SWITCH fi I CIRCUIT BREAKER POWER ON INDICATOR LAMP I 115VWIRING DIAGRAM APACITOR I SWITCH CIRCUIT BREAKER 230V 250VWIRING DIAGRAM 11 SWITCH MO TOR COVER GUN w b CAPACITOR 20 m Rev 1 512 94 Ll...

Страница 5: ...n 13T 44 Bearing M o t o rLower 45 cage 3Planet G e a r 46 Bearing RotatingCover 47 Cover Rotating 48 coupling 49A Spacer B h g Rev 1 5 2 94 49B 70353 3609 7035 53179 53180 73391 73393 87013 70354 310...

Страница 6: ...Position Lock HandleLock Cable Spring PolisherLock Washer M10x 30 Wire Asm 115VL175 Handle Wire Am 220 25OVL175 Washer 5 16 Star Screw 1 2 13x 3 HHCS 70345 Screw 5 16 18 x 2 SHCS Rev 5 2 94 PARTNO 661...

Страница 7: ...208 Use for bothsides 2 7 230V 250V Switch and Terminal Block Asm...

Страница 8: ...Scr 4 40 x 1 4PHMS Pltd SC 1 4 20x 1 2PHTR Pltd Scr 1 4 20x 1 62 SHCSPltd Scr 6 32 x 1 00P P m Pltd Spacer ULSwitch Spacer Adj Handle Switch SnapPOL Handle 230V Clamp 318Nylon W C S A Washer 10 LockEx...

Страница 9: ...uctionsexactly Receptacle not grounded Have an electrician inspect building s wiring Internalwiring problem Ensurethat the machineswiring matchesthe appropriate wiring diagram Replace any wires or com...

Отзывы: