Window Master WLA 340 Скачать руководство пользователя страница 4

 

 

Pulse data 

The pulse which the wind sensor transmits to the control unit - 

/ panel e.g. NV Comfort™ or FlexiSmoke™, depends on the measured 

wind speed, see below table for the wind depending pulse. 

 

Wind speed 

[m/s] 

Pulse /sec. 

10 

12 

14 

16 

18 

10 

20 

11 

22 

12 

24 

13 

26 

14 

28 

15 

30 

16 

32 

 

 

 
 
 

Technical data 

 
Supply voltage: 

24V DC 

Circuit output (rain): 

1 x potential free change-over contact 

Switching capacity: 

60V / 2A 

Pulse signal 

Load =1 x WEI 12M or 1 x WSA 5MC  

Sensor dimensions: 

80 x 160 x 55mm  

(WxHxD / without wind wheel) 

Sensor weight: 

approx. 0.7kg 

Sensor protection type: 

IP65 

CE sign: 

in accordance with the EMC directive and the low voltage directive 

Cleaning:   

 

 

 

 

 

 

 

 

    clean the sensor regularly depending on the degree of soiling. 