background image

Page 2 of 6                                                                                                                                                       Instal Instr Electric Cooktop CTE P Rev B.doc 

SOLID SURFACE COUNTERTOPS

 

 Consult counter manufacturer for requirements. 

 

Countertops made from natural (i.e. granite) or Solid Surface Materials (i.e. Surell™) require special cutout 

preparation and installation procedures. Follow all guidelines in preparing the cutout. 
 

 

Round the cutout corners according to instructions from the countertop manufacturer. 

 

 

Apply heat reflective tape (i.e. Scotch Aluminum Foil Tape #425 or #427) around the cutout so that it folds 
over the top and inside surfaces of cutout. Be sure tape extends to the outermost edge of the cooktop. Cover all 
corners with tape. See FIG 

 2. 

 

 

Install the cooktop and secure to countertop as instructed in next section. 

 

 

Trim the excess, aluminum tape along the frame edges. Use care in trimming tape to avoid scratching 
countertop or stainless steel frame. 

 

COOKTOP INSTALLATION 

 

WARNING 

 DISCONNECT POWER BEFORE INSTALLING COOKTOP. BEFORE 

TURNING POWER “ON” BE

 SURE THAT ALL CONTROLS ARE IN THE 

“OFF” POSITION.

 

 
FOAM TAPE 

 A foam tape is provided to seal the cooktop edges to the countertop. Turn the cooktop upside 

down and apply the tape to bottom side and back edges of stainless steel frame. The tape should be 
approximately 1/16 inch from the edge of the stainless steel frame. See FIG 

 3. 

 
Fastening Cooktop 

 After centering the cooktop in the countertop opening, install the 2 screws provided in the 

side brackets of the countertop. Position a wood block between the end of the screw and the 
countertop, and tighten the screw. 

Do not tighten the screw directly against the 

countertop. See FIG 

 4. 

 

ELECTRICAL CONNECTION 

 

Attach flexible conduit, three (3) foot cable, located at right rear corner of cooktop bottom, to junction box. 

 

 

Connect cooktop lead wires to junction box supply wires, in proper phase: black to black (L1), white to white 
(neutral), red to red (L2), 

and bare wire to ground

. This will result in compliance with the National Electrical 

Code. 

 

 

Location of Data Plate bottom of cooktop. See FIG 

 3. 

 

START UP TEST 

 

 

Remove all items from cooktop 

 

Clean cooktop with cooktop cleaning crème or clean damp cloth.

 

 

Check to see that all controls are in the off position. 

 

Turn power on at service panel. 

 

Turn controls on to check unit operation. Check Power On and Surface Hot signal light operation. 

 

Turn controls off after checking operation. 

 
 

 

 
 

Содержание CTE36P

Страница 1: ...el And Lock Service Disconnecting Means To Prevent Power From Being Switched On Accidentally When The Service Disconnecting Means Cannot Be Locked Securely Fasten a Prominent Warning Device Such As A Tag To The Service Panel POWER SUPPLY Power supply is dual rated 240 VAC or 208 VAC 3 wire 60 Hz 50Amp circuit breaker required for all models JUNCTION BOX Plan the installation of the unit so that th...

Страница 2: ...top edges to the countertop Turn the cooktop upside down and apply the tape to bottom side and back edges of stainless steel frame The tape should be approximately 1 16 inch from the edge of the stainless steel frame See FIG 3 Fastening Cooktop After centering the cooktop in the countertop opening install the 2 screws provided in the side brackets of the countertop Position a wood block between th...

Страница 3: ...RAL AND FIBER BOARDS SURFACE BURNING CHARACTERISTICS This mark is followed by the flame spread and smoke ratings These designations are shown as FHC Flame Spread Smoke Developed Material with 0 flame spread rating are flame retardant Local codes may allow other flame spread ratings The minimum horizontal clearance from the sides and back of the cooktop to the adjacent vertical combustible walls is...

Страница 4: ...IN BOX COUNTERTOP WOOD BLOCK SCREW DOWN HOLD 12 12 DATA PLATE D B A F H E G MODEL CTE36P CTE48P A 48 36 B 25 9 16 25 9 16 D E F G H Dimensional Specifications inches 4 1 4 4 1 4 5 1 16 5 1 16 33 7 8 45 3 8 4 1 2 4 1 2 24 3 4 24 3 4 CUT OUT DIMENSIONS CHANGE SEE ATTACHED END PLATE INSTALLATION INSTRUCTION Notching the Countertop CAUTION IF END PLATES ARE USED THE FOLLOWING ...

Страница 5: ... surface of the End Plates should fit against the front face of the cabinet frame Dimension K Fig 6 will depend on your countertop design If dimension K is greater than 1 inches the countertop will project beyond the front of the cooktop Fig 7 shows a typical installation with a countertop that has a dimension K less than 1 inches Fig 8 shows a typical installation with countertop that has a dimen...

Страница 6: ... FIG 6 CUTOUT FOR COOKTOP USING END PLATE FIG 9 RIGHT HAND END PLATE SHOWN WITH END PLATE COOKTOP SIDE VIEW FIG 8 K WITH END PLATE COOKTOP SIDE VIEW FIG 7 K SIDE VIEW P MODELS FIG 10 OF CABINET FRAME FRONT FACE COUNTER TOP OF CABINET FRAME FRONT FACE COUNTER TOP BURNER BOX COOKTOP GALVANIZED COVERING FOAM TAPE REMOVE PROTECTIVE 23 15 16 20 7 8 1 5 8 5 1 16 25 9 16 4 1 16 4 13 16 END PLATE DIM K SE...

Отзывы: