Interfaces

COM

COM1 (w/o power supply),
COM2* -COM4* (with power supply)
Optional: COM5*- COM8* (with power supply
via PCI-COM Board

USB

4 Standard USB (2 in front, 2 at rear side)
2 P-USB 12V
1 P-USB 24V
Optional:  
4 x 12V P-USB via USB-Controller 

DVI-I/PLINK

DVI-I: up to 2560 x 1600 pixels; 
Panellink: up to 1600x1200 (24 Bit colours)

MIC, SPK

Ports for microphone and loudspeaker

PS/2

1 (e.g. keyboard, mouse)

RJ12

Cash drawer, the jack is situated on the integrated
power supply

DC24V

POS- printer with low voltage on the integrated
power supply

LAN

RJ45- jack, 10/100/1000 Mbit/s

PCI-Bus

1 x PCI 2.1, 32 Bit, 33MHz

PCIe

1 x PCIe

Serial ATA II

3.0 Gbit/s, for internal Hard Disk

Power Save
Interface (RMT)

RJ10/RMT socket

RAID- Controller

optional

38

BEETLE /S-II plus

Содержание BEETLE /S-II plus

Страница 1: ...BEETLE S II plus G41 Motherboard Modular POS System User Manual ...

Страница 2: ...a copy of this page if you have any constructive criticism We would like to thank you in advance for your comments With kind regards Wincor Nixdorf International GmbH Documentation RD HWD01 Rohrdamm 7 D 13629 Berlin E Mail retail documentation wincor nixdorf com Order No 01750211898A ...

Страница 3: ...BEETLE S II plus G41 Motherboard Modular POS System User Manual Edition April 2011 ...

Страница 4: ... without express authority Offenders will be liable for damages All rights including rights created by patent grant or registration of a utility model or design are reserved Delivery subject to availability technical modifications possible All brand and product names mentioned in this document are trademarks of their respective owners ...

Страница 5: ...ng and checking the System 9 Setting up the device 9 Cabling of the BEETLE S II plus 12 Basic settings 13 The System BEETLE S II plus 14 Front Side View 14 ON Button 15 Light emitting Diode LED 15 USB Universal Serial Bus A USB 2 0 15 Interior view 16 Power Supply 17 Connector Panel 17 Power Connector 18 DC24V Modular Printer 18 RJ12 CASHDR Geldlade 18 Power Consumption 19 System Unit 20 Jack Plug...

Страница 6: ...s 25 Storage Media 27 Change of the Data Store 27 USB Controller optional 31 COM5 COM8 Interfaces optional 32 PLINK or DVI D optional 33 Starting up the system 35 Appendix 37 Technical Data BEETLE S II plus 37 Interfaces 38 Extensions 39 Rear Panel Base 39 Rear Panel Base DVI D 39 Rear Panel Base DVI D USB 39 Rear Panel Base DVI D USB COM 40 Total Current Consumption Of Interfaces 41 Glossary 42 A...

Страница 7: ...are designed to provide reasonable protection against harmful inter ference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause ...

Страница 8: ...cts e g office clips find their way into the device as this may lead to electric shocks or short circuits n Never plug in or unplug data communication lines during thunderstorms n Protect devices from vibrations dust moisture and heat n Always dispose of used parts such as batteries in an environmentally safe manner n The ventilation slots must remain unobstructed to ensure sufficient ventilation ...

Страница 9: ...vices only to power supply systems with separately guided protective earth conductor PE This kind of electricity system is known as TN S network Do not use PEN conductors Please also observe the recommendations of the norm DIN VDE 0100 Part 540 Appendix C2 as well as EN50174 2 5 4 3 Thus you can help to avoid possible malfunctions n You can connect or disconnect USB devices during operation of you...

Страница 10: ...rs that offer better performance yet consume more than 30 lesspower than those of previous generations The power supply unit complies with the strict 80 PLUS Bronze supply standard operating with a constant energy efficiency of over 82 The addition of a powered interfaces for peripherals power saving functions in the BIOS and operating system results in a marked reduction in power consumption and ...

Страница 11: ... therefore software will not be discussed further in this manual You will find a description of the BIOS Setup and the Central Processing Unit in a separate manual POS Motherboard see http www wincor nixdorf com internet us Services Support TechnicalSuppo rt POSSystems index html Care of the BEETLE S II plus Clean your BEETLE S II plus at regular intervals with a suitable plastic surface cleaner w...

Страница 12: ...ls onto plastic case parts This would help us to re use components and material At this time there are still some parts that are not reusable Wincor Nixdorf International GmbH guarantees the environmentally safe disposal of these parts in a Recycling Center which is certified pursuant to ISO 9001 and ISO 14001 So don t discard your BEETLE S II plus system on the garbage when it has served its time...

Страница 13: ... improper use of the product or unauthorized modifications of the product n inadequate location or surroundings will not be covered by the warranty For further information on the stipulation consult your contract All parts of the product which are subject to wear and tear are not included in the warranty engagement For detailed warranty arrangements please consult your contract documents Please or...

Страница 14: ...anners such as distance touch or stationary scanners n use scales and scanner scales please take into account the official certification regulations n connect various printers n use POS keyboards n use different types of cash drawers n integrate the BEETLE S II plus in a network and n upgrade the BEETLE M II plus since it can accommodate two expansion cards 2x PCI or 1x PCI PCI Express This means ...

Страница 15: ...fice of Wincor Nixdorf immediately Please indicate the number of your delivery ticket and delivery ticket position and serial numbers of the respective devices The serial numbers can be found on the sample label illustrated below which are located at the bottom side of the housing serial number Transport the device only in its original packaging to protect it against impact and shock Setting up th...

Страница 16: ...aintained and constant ventilation is provided The immediate ambient temperature of the system must not exceed 40 C 104 F Vertical installation of the equipment The minimum top and bottom distances listed in the figure must be maintained otherwise a sufficient ventilation of the equipment is not guaranteed 10 BEETLE S II plus 100 mm 60 mm 50 mm 50 mm 100 mm 60 mm ...

Страница 17: ...the BEETLE S II plus to be suspended by means of the screws n Mind the following minimum clearances also for vertical mounting to ensure sufficient ventilation forward 100 mm backward 60 mm sideways left 50 mm n A surface made of nonflammable material e g concrete or metal must be located underneath the vertically mounted power supply unit BEETLE S II plus 11 ...

Страница 18: ...E S II plus n Plug in and secure the data cable n Plug the other end of the power cable into the main power supply Always make sure that all power plugs from the grounded contact power sockets are unplugged ON Button Power Input Jack 12 BEETLE S II plus DC 24V CASHDR ONLY MIC KYBD RMT COM1 SPK 12V 12V 24V COM2 DVI I USB LAN PLINK DVI D COM3 COM4 COM6 8 COM5 7 ...

Страница 19: ... the particular voltage The power output of the power pack is maximum 304 W Basic settings Ex works the BEETLE S II plus is configured to your order Your configuration must be subsequently adapted to support supplementary devices such as scanners For more information contact the Wincor Nixdorf International GmbH branch office responsible for your area BEETLE S II plus 13 ...

Страница 20: ...The System BEETLE S II plus Front Side View ON Button Power LED HDD LED 2 USB Interfaces Ventilation Slots NOT COVERING 14 BEETLE S II plus ...

Страница 21: ...ed with HDD left LED flashs yellow While the hard disk is beeing accessed POWER right LED lights orange Stand by mode right LED lights green Device is switched on USB Universal Serial Bus A USB 2 0 Interface USB A for connecting different USB peripheral devices such as scanners or scales You must use only shielded cables for the connection of USB devices BEETLE S II plus 15 ...

Страница 22: ...Interior view Power Supply Ventilator power supply Carrier for PCI cards Ventilator processor Cable channel RAM Hard Disk 16 BEETLE S II plus ...

Страница 23: ...W The Power Supply Unit PSU carries the 80plus or 80plus Bronze certificate So less energy is needed and less noise is generated as the fan is much lesser activated with a low revolution speed Connector Panel Power connector DC24V Power supply for the printer HOSIDEN socket RJ12 Cashdrawer socket At the front side of the box you will find the ON button to switch on the system BEETLE S II plus 17 D...

Страница 24: ... connector provides the power Connect the according end of the power cable to this port and the other end to the power socket Pull the mains plug to power off the device DC24V Modular Printer Appropriate POS printers can be connected via the low voltage jack 24V max 3A via non UPS A connecting cable with a HOSIDEN plug is required for this Connect only cables to the 24V connector which are marked ...

Страница 25: ...is therefore directly depending on the operating state All measurements refer to a system configuration of 512MB RAM 80GB 3 5 7200rpm SATA HDD analog flat screen with 1024x768x16 screen resolution WoL enabled Windows XP Professional operating system Power Off soft off 2W Standby Sleep Mode 3W Idle Modes 38W Performance Mode full load 72W 58W Dual Core E2160 processor Celeron 440 processor BEETLE S...

Страница 26: ... allowed exception USB devices Jack plug 3 5 mm MIC Mini DIN KYBD D Sub COM1 RJ10 RMT jack Jack plug 3 5 mm SPK 2 x USB 12V 1 x USB 24V D Sub power supplied COM2 COM3 COM4 24pin DVI I LAN RJ45 socket 2 x USB A USB 2 0 20 BEETLE S II plus DC 24V CASHDR ONLY MIC KYBD RMT COM1 SPK 12V 12V 24V COM2 DVI I USB LAN PLINK DVI D COM3 COM4 COM6 8 COM5 7 ...

Страница 27: ...s supplied to the keyboard via this socket If you wish to connect an older standard PC keyboard with DIN connector you must use a special adapter cable obtainable from the WN branch office responsible for your area When removing cables always take hold of the connector casing Latching connectors can only be released that way D Sub Plug COM1 Connect scales with their own power supply to the COM1 in...

Страница 28: ...rface is qualified for connections of peripheral devices such as printers barcode scanners or customer displays The power supply is either 12V or 24V marked red for POS printers A mechanical code avoids the plugging of a USB 12V connector into a USB 24V jack Always use this onboard P USB 12V to connect a BA82 or BA83 with additional options or any other multifunctional screens D Sub Jack power sup...

Страница 29: ...lly for the Touch screen function and thus is not available for the operation of other peripheral devices DVI I DVI D optional There is a DVI I jack available to connect a high resolution TFT monitor The DVI jack has a dual link contact enabling the transmission of video signals with a max resolution of 2560 1600 pixels 60 hz The DVI D interface is optional available DVI D transfers digital image ...

Страница 30: ...10mBit s green 100mBit s orange 1000mBit s Only connect shielded LAN cables CAT5 CAT5e as these offer a better protection in case of interferences in a network USB Universal Serial Bus A USB 2 0 You can connect several USB peripheral devices to the USB or powered USB interface 12V or 24V Only connect devices equipped with a shielded cable to the USB interfaces 24 BEETLE S II plus ...

Страница 31: ...plugs from the grounded contact power sockets n Unplug all cables from the devices With MINI DIN plugs for Wincor Nixdorf keyboards the plug remains inserted until released Pull the plastic covering from the connecting socket with your thumb The lock is released The metal of the plug is visible RJ12 plugs lock in when you insert them To release them push the latch under the plug to the top The pow...

Страница 32: ...or printer the plug remains inserted until released Pull the plastic covering from the connecting socket with your thumb The lock is released The metal of the plug is visible You loosen the USB A connector by pushing the covering of the connector Manually loosen the knurled screws of the DVI connector 26 BEETLE S II plus ...

Страница 33: ...ating disk to store data The SSD easily subsitutes the hard disk and emulates a hard disk drive interface The most SSDs are flash memory based Change of the Data Store First ensure that the device is switched off and that the power connector is disconnected Open your BEETLE S II plus Loosen the two screws at the back side 1 and pull it out of the front guide 2 Lift the top cover at the back side 3...

Страница 34: ...Push the metal plate 1 Tilt the hard disk holder in direction of arrow 2 Lift up the drive and remove it Loosen the connecting cables 28 BEETLE S II plus Data Cable Cable Power Supply ...

Страница 35: ...ou handle the hard disk with extreme caution during the installation Never touch bare electronics Change the hard disk Please pay regard to the correct fitting position One 2 5 hard disk is being installed at the upper position on the drive holder BEETLE S II plus 29 Connector Socket Drive Holder Buffer Metal Tang ...

Страница 36: ...sponding to the stampings in the base plate see arrows Carefully tilt the hard disk carrier into the orginally position Make sure that the drive holder will not pinsh cables The metal tangs snap in place Close the cover and connect the main plugs Now you can switch on the system 30 BEETLE S II plus ...

Страница 37: ...lso be connected via a USB interface You can connect or disconnect USB devices during operation of your BEETLE provided that these devices comply with the specifications according to usb org Peripheral devices with a high power requirement such as PoweredUSB printer should be connected to or disconnected from your BEETLE system only after the BEETLE has been switched off BEETLE S II plus 31 ...

Страница 38: ...ed COM interfaces together with a PCI COM card Scanners customer and operator displays without power supply of their own are connected to these serial interfaces The interface connection is a 9 pin D sub jack Power 5V or 12V is supplied via this jack Make sure that the connector for the customer display is screwed firmly to the socket to prevent possible malfunctioning 32 BEETLE S II plus COM6 8 C...

Страница 39: ...TFT LCD screen with optional Touch screen function or the connection of a high resolution TFT monitor in case of the 2 DVI The touch functionality must be activated via BIOS Setup BEETLE S II plus backside with PLINK BEETLE S II plus backside with second DVI D BEETLE S II plus 33 PLINK DVI PLINK DVI D ...

Страница 40: ...der all circumstances n You must always discharge yourself e g by touching a grounded object before working with boards containing ESDs n The equipment and tools you use must be free of static charges n Pull out the power plug before inserting or pulling out boards containing ESDs n Always hold boards with ESDs by their edges Never touch pins or conductors on boards fitted with ESDs 34 BEETLE S II...

Страница 41: ... from which the operating system and POS application are to be booted Each medium is assigned a logical drive according to the configuration of your BEETLE S II plus The following media can be assigned a drive n Network n Hard disk n DVD n USB drive The logical drives are designated C and D The network is always assigned to the C drive during the runup procedure The hard disk can be assigned to th...

Страница 42: ...ot find a DVD it automatically continues the loading process from drive C If the operating system has started up without error the POS application software is automatically booted if necessary A message is displayed as soon as the BEETLE is ready for operation For more detailed information see the description of your application program 36 BEETLE S II plus ...

Страница 43: ...tic category Class 3K3 DIN IEC 721 3 3 Class 2K2 DIN IEC 721 3 2 Class 1K2 DIN IEC 721 3 1 Temperature Operating 3K3 5 C up to 40 C Transport 2K2 25 C up to 60 C Storage 1K2 5 C up to 40 C Input voltage 100 120 V 200 240 V Max power consumption 3A 6A Frequency of the 50 60 Hz system voltage Noise development 60 dB A or less Mains power outlet 100 120 V 2 A max 200 240 V 1 A max ...

Страница 44: ... pixels Panellink up to 1600x1200 24 Bit colours MIC SPK Ports for microphone and loudspeaker PS 2 1 e g keyboard mouse RJ12 Cash drawer the jack is situated on the integrated power supply DC24V POS printer with low voltage on the integrated power supply LAN RJ45 jack 10 100 1000 Mbit s PCI Bus 1 x PCI 2 1 32 Bit 33MHz PCIe 1 x PCIe Serial ATA II 3 0 Gbit s for internal Hard Disk Power Save Interf...

Страница 45: ... ONLY MIC KYBD RMT COM1 SPK 12V 12V 24V COM2 DVI I USB LAN PLINK DVI D COM3 COM4 COM6 8 COM5 7 DC 24V CASHDR ONLY MIC KYBD RMT COM1 SPK 12V 12V 24V COM2 DVI I USB LAN PLINK DVI D COM3 COM4 COM6 8 COM5 7 DC 24V CASHDR ONLY MIC KYBD RMT COM1 SPK 12V 12V 24V COM2 DVI I USB LAN PLINK DVI D COM3 COM4 COM6 8 COM5 7 ...

Страница 46: ...Rear Panel Base DVI D USB COM or PLINK 40 BEETLE S II plus DC 24V CASHDR ONLY MIC KYBD RMT COM1 SPK 12V 12V 24V COM2 DVI I USB LAN PLINK DVI D COM3 COM4 COM5 COM6 COM6 8 COM5 7 ...

Страница 47: ...ption at 12V interfaces must not exceed 5A each COM 2 3 4 600mA in total 900mA each COM 5 6 600mA in total 900mA each PUSB 12V 3A each PUSB 12V 1 5A TFT LCD Display Max 5A 12V The total current consumption at 24V interfaces must not exceed 3A each PUSB 24V 3 0A 24VDC power supply Max 3A 24V Power loss of additionally implemented PCI and PCIe Controllers is for thermic reasons limited to 10W for ea...

Страница 48: ...in the digital to analog conversion and following analog to digital conversion that can occur in current digital display devices DVI has three subsets DVI A for analog signals DVI D for digital signals and DVI I integrated for both analog and digital signals In the future PCs and laptops are not only equipped with DVI but also video devices as DVD Interface Designates the transition point between ...

Страница 49: ...integration and configuration of new components is made substantially easier Peripherals Devices serving as an input output device or storage for a computer This includes for example document readers keyboards printers and disk storage SATA Abbreviation for Serial Advanced Technology Attachments a serial interface By using the serial transmission SATA will do with a thin four wired conductor and a...

Страница 50: ...l Organization for Standardization LAN Local Area Network LCD Liquid Crystal Display LED Light Emitting Diode NV RAM non violate RAM OS Operating System PCI Peripheral Component Interconnect PCIe Peripheral Component Interconnect express PEN Leiter Protective Earth Neutral Leiter PLINK Panel Link PnP Plug and Play Plug Play POS Point Of Sales PS Power Supply RAID Redundante Anordnung unabhängiger ...

Страница 51: ...ktronik und Informationstechnik e V German Association for Electrical Electronic and Information Technologies WAN Wide Area Network WLAN Wireless Local Area Network WN Wincor Nixdorf International GmbH ZC Zero Cache BEETLE S II plus 45 ...

Страница 52: ...Herausgegeben von Published by Wincor Nixdorf International GmbH D 33094 Paderborn Bestell Nr Order No 01750211898A ...