3
REV C
60706-220
SPECIFICATIONS
GENERATOR
Model W3000H
Starting
Watts
3,000
Running Watts
2,400
Volts
120
Starting
Amps
25
Running
Amps
20
Generator Manufacturer
Mecc Alte Spa
Generator Model Number SF15W-75
Part
Number
16346-008
Rotor Resistance
4.356 Ohms
Stator Resistance
2.165 Ohms
Regulation Capacitor
ENGINE
Engine Manufacturer
Honda
Engine Model Number
GC160 LVXA
Fuel
Type
Gasoline
Oil Capacity
20 oz. (0.625 qts)
SAFETY
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
This manual contains important information that should be understood
and followed before the installation, operation and maintenance of the
generator. Failure to follow the safety instructions in this manual could
result in serious injury or death. Keep this manual available for future
reference.
CALIFORNIA PROPOSITION 65
WARNING:
This product contains crude oil, gasoline,
diesel fuel and other petroleum products, Antifreeze to
which can expose you to chemicals including toluene
and benzene, Ethylene glycol (ingested) which are
known to the State of California to cause cancer, birth defects or other
reproductive harm and developmental issues.
For more information go to www.P65Warning.ca.gov.
ANSI SAFETY DEFINITIONS
DANGER:
DANGER indicates an imminently hazardous situation which, if not
avoided,
will
result in death or serious injury. This signal word is to be
limited to the most extreme situations.
WARNING:
WARNING indicates a potentially hazardous situation which, if not
avoided,
could
result in death or serious injury.
CAUTION:
CAUTION indicates a potentially hazardous situation which, if not
avoided,
may
result in minor or moderate injury. It may be used to alert
against unsafe practices.
NOTE: CAUTION is also used on the unit labels and in this manual to
indicate a situation that could result in serious damage or destruction of
the equipment and possible personal injury.
1. ELECTRICAL SHOCK -
The output voltage present in this equipment can cause fatal electric
shock. This equipment must be operated by a responsible person.
A. Do not allow anyone to operate the generator without proper
instruction.
B. Guard against electric shock.
C. Avoid contact with live terminals or receptacles.
D. Use extreme care if operating this unit in rain or snow.
E. Use only three-pronged grounded receptacles
and extension cords.
F. Be sure the unit is properly grounded or your application.
2. FIRE HAZARD -
Gasoline and other fuels present a hazard of possible explosion and/
or fire.
TESTING POLICY
Before any generator is shipped from the factory, it is fully checked
for performance. The generator is loaded to its full capacity, and the
voltage, current, and frequency are carefully checked.
Rated output of generator is based on engineering tests of typical units,
and is subject to, and limited by, the temperature, altitude, fuel, and
other conditions specified by the manufacturer of applicable engines.