SAFETY

IMPORTANT SAFETY INSTRUCTIONS

This engine generator set has been designed and 

manufactured to allow safe, reliable performance. Poor 

maintenance, improper or careless use can result in 

potentially deadly hazards; from electrical shock, exhaust 

gas asphyxiation, or fire. Please read all safety instructions 

carefully before installation or use. Keep these instructions 

handy for future reference. Take special note and follow all 

warnings on the unit labels and in the manuals.

SAFETY DEFINITIONS

DANGER

Indicates an imminently hazardous situation 

which, if not avoided, will result in death or 

serious injury. 

WARNING

Indicates a potentially hazardous situation 

which, if not avoided, could result in death 

or serious injury.

CAUTION

Indicates a potentially hazardous situation 

which, if not avoided, may result in minor or 

moderate injury. It may also be used to alert 

against unsafe practices.

CALIFORNIA PROPOSITION 65

WARNING: This product contains crude oil, 

gasoline, diesel fuel and other petroleum 

products, Antifreeze to which can expose you 

to chemicals including toluene and benzene, 

Ethylene glycol (ingested) which are known to the 

State of California to cause cancer, birth defects or other 

reproductive harm and developmental issues. 

For more information go to www.P65Warning.ca.gov.

DANGER: ELECTRICAL SHOCK 

The output voltage present in this equipment can cause 

fatal electric shock. This equipment must be operated by a 

responsible person.

  A. Do not allow anyone to operate the generator 

   without 

proper 

instruction.

  B. Guard against electric shock.

  C. Avoid contact with live terminals or receptacles.

  D. Use extreme care if operating this unit in rain or 

   snow.

  E. Use only three-pronged grounded receptacles 

   and 

extension 

cords.

  F. Be sure the unit is properly grounded for your 

   application.

DANGER: DEADLY EXHAUST GAS

Exhaust fumes from any gasoline engine contain carbon 

monoxide, an invisible, odorless and deadly gas that must 

be mixed with fresh air.

  A. Operate only in well ventilated areas.

  B. Never operate indoors including attached 

   garages

  C. Never operate the unit in such a way as to allow 

      exhaust gases to seep back into closed rooms 

      (i.e. through windows, walls, floors).

WARNING: FIRE HAZARD

Gasoline and other fuels present a hazard of possible 

explosion and/or fire.

  A. Do not refuel when the engine is running or hot.

  B. Keep fuel containers out of reach of children.

  C. Do not smoke or use open flame near the 

      generator set or fuel tank.

  D. Keep a fire extinguisher nearby and know its 

      proper use. Fire extinguishers rated ABC by 

   NFPA 

are 

appropriate.

  E. Store fuel only in an approved container, and 

      only in a well ventilated area.

  F. Follow local codes for closeness to combustible 

   material.

CAUTION: PERSONAL INJURY

The muffler becomes very hot during operation and for a 

period after the unit has been turned off. Do not touch the 

muffler until it has completely cooled off.

CAUTION: NOISE HAZARD

Excessive noise is not only tiring, but continual exposure 

can lead to loss of hearing.

  A. Use hearing protection when working around 

      this equipment for long periods of time.

  B. Keep your neighbors in mind when using this 

   equipment.

CAUTION

Keep the generator and surrounding area clean.

  A. Remove all grease, ice, snow or materials that 

   create 

      slippery conditions around the unit.

  B. Remove any rags or other materials that could 

      create a potential fire hazard.

  C. Carefully clean up any gas or oil spills before 

   starting 

the 

unit.

CAUTION

All service, including the installation or replacement of 

service parts, should be performed only by a qualified 

technician.

  A. Use only factory approved repair parts.

  B. Do not work on this equipment when fatigued.

  C. Never remove the protective guards, covers, or 

      receptacle panels while the engine is running.

  D. Use extreme caution when working on electrical 

      components. High output voltage from this 

      equipment can cause serious injury or death.

  E. Always avoid hot mufflers, exhaust manifolds, 

      and engine parts. They can cause severe burns 

   instantly.

  F. The use of the engine-generator set must comply 

      with all national, state, and local codes.

Содержание PSS20B2W/A

Страница 1: ...ld ever need to contact us on this unit it will help us to respond to your needs faster MODEL __________________________________________________ SERIAL NUMBER _________________________________________...

Страница 2: ...Y INSTALLATION 11 SERVICING BATTERIES BATTERY CHARGING CONNECTING BATTERY CHARGER GENERATOR CONNECTIONS WINCO UL ATS ASCO 185 AC ELECTRICAL CONNECTIONS 13 ASCO 185 UL SWITCH DC ELECTRICAL INTERCONNECT...

Страница 3: ...NCO generator You have selected a high quality precision engineered generator designed and tested to give you years of satisfactory service To get the best performance from your new generator it is im...

Страница 4: ...t must be mixed with fresh air A Operate only in well ventilated areas B Never operate indoors including attached garages C Never operate the unit in such a way as to allow exhaust gases to seep back...

Страница 5: ...Vapor 2520 BTU FT CF HR 328 130 5 BTU HR 328 000 329 000 GAL HR N A 3 61 Based on full load operation LP TANK SIZING Tank Temperature Tank Size 60 F 16 C 150 Gallons 32 F 0 C 250 Gallons 0 F 18 C 500...

Страница 6: ...nt The ATS also contains the power failure sensing circuitry necessary to start and stop the engine generator set The transfer switch is also equipped standard with a 3 second start delay and a 15 sec...

Страница 7: ...d quantity of oil required is listed in the engine operator s manual and under the service tab in this manual This unit was shipped with most of the oil removed The engine normally holds 80 ounces 2 5...

Страница 8: ...ormation in this manual is offered only as a guide to finalizing your installation plans WARNING PERSONAL INJURY The enclosures on these units can become very hot adjacent to the exhaust areas Special...

Страница 9: ...egulator Consult your local fuel supplier for your exact requirements The appropriate line size from the following table is then installed from the low pressure regulator to the generator set Feet Siz...

Страница 10: ...0 15 lbs 7 11 in 4 6 oz 7 11 in 4 6 oz No load Line PSI 10 15 lbs 7 11 in 4 6 oz 7 11 in 4 6 oz Full load Line PSI 10 15 lbs 7 11 in 4 6 oz 7 11 in 4 6 oz Natural gas Ref 2 3 4 Unit off 2 PSI 7 11 in...

Страница 11: ...first and the positive cable last Failure to connect and disconnect in the proper sequence can cause equipment damage Observe polarities connect the positive battery terminal to the cable from the eng...

Страница 12: ...ordance with the United States National Electric Code These AC wires can be run in the same conduit as the other AC leads from the generator It is suggested that this circuit be fused for 15 Amps Term...

Страница 13: ...the terminals L2 L6 The normal line power terminals in the ATS are marked PREFERRED L1 L5 The hot line power leads are L1 and L3 from the utility power supply They are connected to terminals L1 and L...

Страница 14: ...re to be powered under emergency power failure conditions an additional distribution panel designated emergency distribution panel must be installed All selected emergency circuits are removed from ma...

Страница 15: ...through 9 These terminals will accept 22 14 AWG stranded wire It is recommended that you use 16 AWG for distances up to 200 feet You need to run two 2 wires from the engine generator set to the transf...

Страница 16: ...is ready for the initial start up test START UP PROCEDURE ENGINE GENERATOR SET ONLY The engine control module ECM is manufactured by Deep Sea Electronics Model 3110 is used on this generator set See...

Страница 17: ...e system This operation starts the generator and transfers the load The controller is shipped with a load transfer set by default Changing the exercise without a load will be discussed later Be sure t...

Страница 18: ...ing the exercise period including cool down The light stays on to indicate that the exerciser has been set If the light is off the exerciser has not been set CANCELING AN ACTIVE EXERCISE PERIOD Press...

Страница 19: ...19 60706 229 G...

Страница 20: ...Auxiliary inputs can be user configured and will display he message as written by the user Fail to Start The engine has not fired after the preset number of start attempts Fail to Stop The module has...

Страница 21: ...The fault must be removed and the Stop Reset button pressed to reset the module The icon will appear flashing in the display MODULE DISPLAY TIMER ICON When the module is controlling the engine startin...

Страница 22: ...and not burned or pitted ENGINE GENERATOR SET Service the engine in accordance with the engine manufacturer s manual provided with your new equipment Routinely remove debris and dirt from around the...

Страница 23: ...ked up engine generator set 9 Defective starter fuel solenoid relays ENGINE CRANKS BUT WILL NOT START 1 Improper fuel pressure being delivered to unit 2 Fuel supply shut off 3 Fuel supply empty 4 Defe...

Страница 24: ...24 60706 229 G OUTLINE DRAWING...

Страница 25: ...25 60706 229 G PAD LAYOUT 60706 229 23 12270 01 60706 229 ET A ENGINE GENERATOR SET PAD LAYOUT...

Страница 26: ...26 60706 229 G AC AND DC GENERATOR SCHEMATIC...

Страница 27: ...27 60706 229 G AC WIRING SCHEMATIC PSS20 3 A PSS20 17 A PSS20 18 A PSS20 4 A...

Страница 28: ...does not cover travel time mileage or labor for removal or re installation of WINCO product from its application Normal wear and tear Costs of rental equipment WINCO does not warrant engines Engines a...

Отзывы: