background image

28

OPM-147/C

WINCO Inc. has been engineering and manufacturing high quality generators since 1927. WINCO Inc. warrants to the original owner that the purchased 
product is free from defects in materials and/or workmanship for the period of time outlined below. If the product should prove defective within the time period 
outlined below, it will be repaired, adjusted or replaced at the option of WINCO Inc., provided that the product, upon inspection by an authorized WINCO Inc. 
service center, has been found to have been properly installed, maintained and operated in accordance with WINCO Inc.’s Installation and Operating Manuals, 
engine manufacturer installation and operation guidelines, and National and local code. This limited warranty is not valid or enforceable unless:
 

1. All supporting product maintenance records are kept on file and made available upon request from WINCO Inc. 

 

2. A copy of the WINCO Inc. Start-up Completion and Warranty Validation Checklist is properly and completely filled out and returned to 

 

  WINCO Inc. within 30 days of start-up. 

 

3. The product is routinely exercised in accordance with operating instructions. This warranty does not apply to malfunctions caused by 

 

  physical damage, misuse, improper installation, repair or service by unauthorized persons; or normal wear and tear. The warranty is 

 

  not assignable.

WINCO Inc. Product Warranty Period:
 

• Engine generator set: Parts and Labor for one (1) years from the date of factory invoice or 2,000 hours (whichever occurs first).

 

• Accessories (installed on the product or shipped loose): Parts and Labor for one (1) year from the date of factory invoice or 2,000 hours 

 

  (whichever occurs first).

 

The start of the warranty period can be adjusted to the date of unit start-up (limited up to 180 days from invoice date) provided that the  

 

following information is provided to WINCO Inc. at the time of start-up: 

 

  1. A copy of the WINCO Inc. Start-up Completion and Warranty Validation Checklist is properly and completely filled out and returned to 

 

    WINCO Inc. within 30 days of start-up. 

 

  2. Some engines may require revalidation after long-term storage. The engine revalidation process if included in the manual must be 

 

  followed.

To obtain warranty service: 
 

Contact your nearest authorized WINCO Inc. service center. For assistance in locating your nearest authorized service center, contact WINCO 

 

Inc.’s Service Department.

Warranty service may be performed by an authorized WINCO Inc. service center only. Service work performed by unauthorized persons will void all warranties.

WINCO Inc. shall not be liable for any claim in an amount greater than the purchase price of the product. In no event shall WINCO Inc. be held liable for any 
special, indirect, consequential or liquidated damages.

WINCO Inc. shall not be liable for any claim that requires replacement of engine, part, or component of the product that is no longer manufactured or available. 
Additionally, WINCO Inc. will not be liable for any engine replacement that may require an emissions tier-level change.

THERE ARE NO EXPRESS WARRANTIES OTHER THAN THOSE DESCRIBED HEREIN. THERE ARE NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, OR 
OTHERWISE CREATED UNDER THE UNIFORM COMMERCIAL CODE, INCLUDING BUT NOT LIMITED TO WARRANTIES OF MERCHANTABILITY, OR WARRANTIES 
OF FITNESS FOR A PARTICULAR PURPOSE.

The following items and/or circumstances are excluded from this limited warranty:
 

• Engine starting batteries: The battery manufacturers’ warranty applies. Consult your local battery supplier for warranty service. 

 

• Fuel system and/or governing system adjustments performed during or after start-up.

 

• Normal maintenance items: Consumable items such as belts, filters and hoses.

 

• Damage caused by over-loading the generator and failure to adequately provide over-load protection.

 

• LP/NG fuel adjustments or conversion from one fuel to another.

 

• Any repeat or shop come-back repairs resulting from poor service work or improper diagnosis and testing. Replacement of parts as a trial-and-error 

 

  method of diagnosis will not be considered for warranty.

 

• Adjustments and tune–ups performed during start-up or thereafter. 

 

• Loose connections (electrical and mechanical) not found during start-up.

 

• All fluid level related items including low coolant not found during start-up or checked during regular maintenance intervals. 

 

• Equipment modifications made without the written consent of WINCO Inc. will void all warranties.

 

• Shipping damage of any type. All equipment is shipped F.O.B. factory and risk of loss transfers to the carrier once loaded for shipment. It is the 

 

  responsibility of the receiving party to sign for the receipt of, and note any shipping damage to the equipment. Freight damage claim filing is the 

 

  responsibility of the receiving party. In the rare event that damage occurs during shipment, WINCO Inc. will not warrant any damage to the unit 

 

  resulting from packaging material.

 

• Any special access fees, requirements or after hours scheduling to gain access to the equipment for warranty service purposes. 

 

• Rental generators used while warranty work is being performed.

 

• Damages caused by acts of nature, such as lightning, wind, flood, wild fires, or earthquake.

 

• Any damage due to situations beyond the control of the manufacturing and/or workmanship of the product. 

 

• Use of non-protected steel enclosure within 25 miles of the coast.

 

• Damage caused by improper installation or failure to provide adequate ventilation.

 

• Misapplication of the equipment such as usage outside the original design parameters as stated on the nameplate of the equipment. 

 

• Equipment purchased at the standby rating that is being used in a prime power application(s).

 

• Diesel engine “Wet Stacking” due to lightly loaded diesel engines.

 

• Travel time or service calls unless given written authorization by WINCO Inc.

ENGINE GENERATOR SET 

ONE (1) YEAR, 2,000 HOUR PRIME

LIMITED WARRANTY

WINCO INC. • 225 S. CORDOVA AVE • LE CENTER, MN  56057 • 507-357-6821

Содержание DE2314 Series

Страница 1: ...ever need to contact us on this unit it will help us to respond to your needs faster MODEL __________________________________________________ SERIAL NUMBER _________________________________________ P...

Страница 2: ...ERATIONS COLD WEATHER OPERATIONS MAINTENANCE 19 CHANGING THE OIL CHANGING OIL FILTER CHANGING COOLANT REFILLING COOLANT CHANGING AIR FILTER CHECKING WATER IN FUEL FILTER CLEANING RADIATOR CHANGING THE...

Страница 3: ...AZARD Gasoline and other fuels present a hazard of possible explosion and or fire A Do not refuel when the engine is running or hot B Keep fuel containers out of reach of children C Do not smoke or us...

Страница 4: ...120 240 277 480 Phase Single Three Three Three PF 1 0 0 8 0 8 0 8 Amps 82 71 62 31 Hertz 60 60 60 60 ENGINE Model Isuzu 4LE2T Starting System 12 Volt Fuel Consumption full load 2 1 Gal hr Fuel ASTM D...

Страница 5: ...e series star connected Exciter Rotor 0 201 per phase Exciter Stator 14 7 DE40I4 STANDBY MODEL DE40I4 03 DE40I4 04 DE40I4 17 DE40I4 18 DE40I4 21 Watts 36 000 39 000 39 000 39 000 39 000 Volts 120 240...

Страница 6: ...e information recorded inside the front cover of this manual for future reference and for identification whenever requesting field or factory assistance Primary fields needed for assistance are comple...

Страница 7: ...ction manual c Start up and warranty validation form d Battery hold down brackets hardware e Unit components or accessory items shipped loose for on site installation f Optional accessories 3 Remove m...

Страница 8: ...ible to lift the generator from the radiator side It requires especially long forks and care should be taken to ensure that no contact is made with the radiator Pushing the radiator will cause damage...

Страница 9: ...eriorate and the unit mountings will come loose These units must be mounted to a steel or concrete base VENTILATION REQUIREMENTS WARNING EQUIPMENT DAMAGE It is the installer s responsibility to ensure...

Страница 10: ...he fuel inlet pump If your fuel supply is lower than 3 feet you may have to install an additional lift pump to bring the fuel up to the mechanical fuel pump on the engine The information in this manua...

Страница 11: ...rator should only supply equipment that is cord and plug connected through customer installed receptacles mounted on the generator or the vehicle PERMANENTLY INSTALLED GENERATORS This WINCO portable g...

Страница 12: ...emergency stops may be desired or necessary The controller has terminals designed allowing the addition of multiple remote emergency stops E stops must be normally closed to work properly in this syst...

Страница 13: ...1 Always wear full eye protection and protective clothing 2 Where electrolyte contacts skin wash off immediately with water 3 If electrolyte contacts the eyes flush thoroughly and immediately with wa...

Страница 14: ...f Auto Maintain Mode The illuminated Green auto maintain LED This indicates your 12volt battery is fully charged During short or long term storage periods Auto Maintain Energy Saver mode will monitor...

Страница 15: ...Authorized Monograde CAUTION PERSONAL INJURY Only check oil when the engine is not running and is at a low temperature in order to avoid the risk of burns 1 Remove the dipstick and ensure the oil lev...

Страница 16: ...n 480 units The same approximate voltage should be found between terminals G3 and G N 120 volts AC On three phase panels the G2 voltage level should also be checked ON 240 VOLT DELTA SYSTEMS BE SURE Y...

Страница 17: ...e initial start up or prior to start up it is most likely a false warning light Simply reset the ATS to start over Once you have completed testing of the ATS be sure you ALWAYS leave the system in the...

Страница 18: ...testing program can also provide early warnings or oil degradation Efforts may need to be made to reduce the amount of dust and debris entering the housing and generator components COLD WEATHER OPERA...

Страница 19: ...e of the cylinder block Discharge the coolant inside the engine MAINTENANCE CHANGING THE OIL CAUTION PERSONAL INJURY Only change oil when the engine is not running and is at a low temperature in order...

Страница 20: ...AMAGE Clean the exhaust valve prior to checking the pre filter to reduce the risk for system contamination Do NOT perform while the engine is running 1 Place a container for collecting liquids under t...

Страница 21: ...he previous paragraph 6 Close all of the engine s intake discharge ventilation and bleeding holes with plugs or seal them with adhesive tape 7 Drain the residual 30 M protective oil from the sump whic...

Страница 22: ...fuel solenoid Defective engine harness Improper battery voltage to fuel pump or fuel solenoid Engine starts then stops and alarm light comes on Engine oil pressure is low Engine has high water temper...

Страница 23: ...THHW THW 2 XHH XHHW XHHW 2 ZW 2 SIZE AWG OR KCMIL Wire Type RHW THHW THW THWN XHHW USE Wire Type TBS SA SIS THHN THW 2 THWN 2 RHH RHW 2 USE 2 XHH XHHW XHHW 2 ZW 2 50 65 85 100 115 130 150 175 200 230...

Страница 24: ...ANK 95 SP 5V4 109 SG 5VRT4 100 SG SLD5 98 IF CAM 101 SG 5VRT5 65 IA THCO 70 IA OILPRESS 84 IA THW 93 IS EBMPOS 2 94 IS EBMPOS 1 99 IS EBMPOS 3 25 IS ENGSTP 28 IS IDLUP 27 IS IDLMNL 26 IS IDLDWN 49 IS...

Страница 25: ...5 7 50 1 2 6 211 725 211 725 66 86 86 86 86 86 36 1 2 8 1387 20021 6 5 1 1 6 5 1 1 1 1 1 36 32 5 6 7 66 0 5 1 6723 6 7 66 8 6 7 21 6 7 9 5 92 7 8670 17 5 267 7 9 5 1 855 17 66 7 50 1 2 803 56 6 2 1 29...

Страница 26: ...26 OPM 147 C THREE PHASE AC WIRE HIGH AND LOW WYE WIRING DIAGRAMS...

Страница 27: ...27 OPM 147 C THREE PHASE AC WIRING DELTA SINGLE PHASE 311 WINDING...

Страница 28: ...oduct that is no longer manufactured or available Additionally WINCO Inc will not be liable for any engine replacement that may require an emissions tier level change THERE ARE NO EXPRESS WARRANTIES O...

Отзывы: