W632GU6NB
Publication Release Date: Aug. 20, 2018
Revision: A01
- 47 -
8.13.2.2 READ Timing; Data Strobe to Data relationship
The Data Strobe to Data relationship is shown in Figure 25 and is applied when the DLL is enabled
and locked.
Rising data strobe edge parameters:
t
DQSQ
describes the latest valid transition of the associated DQ pins.
t
QH
describes the earliest invalid transition of the associated DQ pins.
Falling data strobe edge parameters:
t
DQSQ
describes the latest valid transition of the associated DQ pins.
t
QH
describes the earliest invalid transition of the associated DQ pins.
t
DQSQ
; both rising/falling edges of DQS, no t
AC
defined.
T0
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
CK#
CK
Command*
3
READ
Address*
4
NOP
NOP
NOP
NOP
NOP
NOP
NOP
Bank
Col n
DQS, DQS#
DQ*
2
(Last data valid)
Dout
n
t
RPRE
t
RPST
NOP
NOP
NOP
RL = AL + CL
Dout
n
Dout
n+1
Dout
n+2
Dout
n+4
Dout
n+5
Dout
n+6
Dout
n+7
Dout
n+1
Dout
n+2
Dout
n+4
Dout
n+5
Dout
n+6
Dout
n+7
Dout
n+1
Dout
n+2
Dout
n+3
Dout
n+4
Dout
n+5
Dout
n+6
Dout
n+7
t
QH
t
DQSQ
(max)
t
DQSQ
(max)
t
QH
DQ*
2
(first data no longer valid)
All DQs collectively
TRANSITIONING DATA
DON'T CARE
Dout
n
Dout
n+3
Dout
n+3
Notes:
1. BL = 8, RL = 6 (AL = 0, CL = 6).
2. Dout n = data-out from column n.
3. NOP commands are shown for ease of illustration; other commands may be valid at these times.
4. BL8 setting activated by either MR0 A[1:0] = 00 or MR0 A[1:0] = 01 and A12 = 1 during READ command at T0.
5. Output timings are referenced to V
DDQ
/2, and DLL on for locking.
6. t
DQSQ
defines the skew between DQS, DQS# to Data and does not define DQS, DQS# to Clock.
7. Early Data transitions may not always happen at the same DQ. Data transitions of a DQ can vary (either early or late) within
a burst.
Figure 25
– Data Strobe to Data Relationship