W632GU6NB
Publication Release Date: Aug. 20, 2018
Revision: A01
- 132 -
10.13.2 I
DD
Current Specifications
SYM.
Speed Bin
DDR3L-
1333
DDR3L-
1600
DDR3L-
1866
DDR3L-
2133
UNIT
Part Number Extension
-15/15I/15J -12/12I/12J -11/11I/11J -09/09I/09J
DEFINITION
MAX.
MAX.
MAX.
MAX.
I
DD0
Operating One Bank Active-Precharge
Current
110
120
135
140
mA
I
DD1
Operating One Bank Active-Read-
Precharge Current
130
145
160
175
mA
I
DD2N
Precharge Standby Current
80
85
95
100
mA
I
DD2NT
Precharge Standby ODT Current
95
105
115
130
mA
I
DD2P0
Precharge Power Down Current Slow Exit
16
16
16
16
mA
I
DD2P1
Precharge Power Down Current Fast Exit
45
50
55
60
mA
I
DD2Q
Precharge Quiet Standby Current
80
85
95
100
mA
I
DD3N
Active Standby Current
85
95
100
110
mA
I
DD3P
Active Power Down Current
55
60
65
70
mA
I
DD4R
Operating Burst Read Current
165
190
210
230
mA
I
DD4W
Operating Burst Write Current
185
210
235
260
mA
I
DD5B
Burst Refresh Current
175
180
190
195
mA
I
DD6*
3
Normal Temperature Self-Refresh Current
15
15
15
15
mA
I
DD6ET*
4
Extended Temperature Self-Refresh
Current
16
16
16
16
mA
I
DD7
Operating Bank Interleave Read Current
205
235
260
290
mA
I
DD8
RESET# Low Current
16
16
16
16
mA
Notes:
1. Max. values for I
DD
currents consider worst case conditions of process, temperature and voltage.
2. The I
DD
values must be derated (increased) when operated outside the range 0°C
≤ T
CASE
≤ 85°C:
(a) When T
CASE
< 0°C: I
DD2P0
, I
DD2P1
and I
DD3P
must be derated by 4%; I
DD4R
and I
DD5W
must be derated by 2%; and
I
DD6
, I
DD6ET
and I
DD7
must be derated by 7%.
(b) When T
CASE
> 85°C: I
DD0
, I
DD1
, I
DD2N
, I
DD2NT
, I
DD2Q
, I
DD3N
, I
DD3P
, I
DD4R
, I
DD4W
, and I
DD5B
must be derated by
2%; and I
DD2P0
, I
DD2P1
must be derated by 30%.
3. Set MR2 A[6] = 0b, Auto Self-Refresh (ASR) disable; Set MR2 A[7] = 0b, Self-Refresh Temperature Range (SRT) disable for
normal temperature range.
4. Set MR2 A[6] = 0b, ASR disable; Set MR2 A[7] = 1b, SRT enable for extended temperature range.