background image

 

WINAICO is a trademark of Win Win Precision Technology Co., Ltd.

 

www.winaico.com

 

SIM2205-01(EN) 

 

 

 

          16 

8.

 

Liability disclaimer 

 

These installation and assembly instructions apply in general to standard systems. No responsibility is accepted for the 
correctness  of  this  information.  WINAICO  does  not  provide  any  guarantee  of  the  usability  and  serviceability  of  the 
modules if the user fails to observe this user information. As compliance with this user information and the conditions 
and methods for the installation, operation, use and maintenance of the modules from WINAICO cannot be checked or 
monitored,  WINAICO  shall  assume  no  liability  for  damages  resulting  from improper use,  faulty  installation, operation, 
use  or  maintenance.  In  addition,  no  liability  shall  be  borne  for  infringements  of  patent  laws  or  other  rights  of  third 
parties which result from the use of the modules, unless mandated by law. 

 

9.

 

Contacts 

If you have any questions, our WINAICO Team is available to assist you at all times

Taiwan Headquarters

 

Win Win Precision Technology Co., Ltd.

 

4F., No.180, Sec. 2, Gongdao 5th Rd., East, Dist. Hsinchu City 300, Taiwan 

 

[email protected]

 

 

WINAICO Deutschland GmbH 

Industriestraße 68, 97993 Creglingen 
Germany 
Phone: +49 7933 700 300 

[email protected]

 

 

WINAICO Australia Pty Ltd

 

3/393 George Street, Sydney NSW 2000 
Australia 
Phone: +61 2 8091 2771 

[email protected]

 

 

WINAICO USA

 

960 Rand Road, Suite 200 E, Des Plaines, IL 60016 

USA    

Phone: + 1 847 460 5062 

[email protected]

 

 

WINAICO Japan KK

 

7F Humax Ebisu Building, Ebisu Minami 1-1-1, Shibuya-ku 150-0022 Tokyo 
Japan 
Phone: +81 (0) 3 5456 5798 

[email protected]

 

 

 

WINAICO is a trademark of 
Win Win Precision Technology Co., Ltd.

 

 

Version 31/MAY/2022 

Содержание WST-MG 6X18

Страница 1: ...WINAICO is a trademark of Win Win Precision Technology Co Ltd www winaico com SIM2205 01 EN Installation Manual Crystalline modules...

Страница 2: ...l installation 12 Module selection 12 Diodes and fuses 12 Cables and connectors 13 Safetyprecautions 14 6 3 Grounding 14 7 CLEANING AND MAINTENANCE 15 8 LIABILITY DISCLAIMER 16 9 CONTACTS 16 Win Win P...

Страница 3: ...s We recommend that you insure your WINAICO photovoltaic system from natural and other hazards e g lightning strikes vandalism If there are any points of ambiguity WINAICO recommends confirming propos...

Страница 4: ...a 1 600 Pa 3 600 Pa 1 600 Pa Max test load push pull 5 400 Pa 2 400 Pa 5 400 Pa 2 400 Pa 5 400 Pa 2 400 Pa Module series WST MGL 6X20 WST MG 6X20 WST MG 6X18 Dimensions mm 1 767 x 1 050 x 35 1 759 x 1...

Страница 5: ...WINAICO is a trademark of Win Win Precision Technology Co Ltd www winaico com SIM2205 01 EN 3 WST MGX P3 6X18 WST MGX P1 6X18 WST MGX E1 6X18...

Страница 6: ...WINAICO is a trademark of Win Win Precision Technology Co Ltd www winaico com SIM2205 01 EN 4 WST MGL 6X20 WST MG 6X20 WST MG 6X18...

Страница 7: ...s are between 40 C and 85 C Hazardous voltages IEC 61730 higher than 50V DC EN61730 higher than 120V DC hazardous power applications higher than 240W where general unrestricted access is anticipated M...

Страница 8: ...s Many issues caused by rough handling will arise years after the installation Taking additional care can save considerable time and money from avoided service calls and replacements It is recommended...

Страница 9: ...terials Solar modules are non explosion protectedequipment Mounting site Orientation The performance of WINAICO Panels is dependent on the available solar resource as well as their positioning in rela...

Страница 10: ...tion work in high winds Secure yourself and other persons against falling Prevent the possibility of falling objects Secure the work area so that no other persons can be injured Keep children away fro...

Страница 11: ...Figure below for each fastening point must have an area of at least 135 mm 2 A torque wrench must be used for assembly In the examples shown the tightening torque using M8 bolts produced from V2A is 2...

Страница 12: ...600 Pa Rear pull 1600 Pa WST MGX E1 6X18 Test Load Front push 5400 Pa Test Load Front push 2400 Pa Rear pull 2400 Pa Rear pull 2400 Pa Design Load Test load 1 5 Front push 3600 Pa Design Load Test loa...

Страница 13: ...00 Pa Rear pull 1600 Pa WST MG 6X18 Test Load Front push 5400 Pa Test Load Front push 2400 Pa Rear pull 2400 Pa Rear pull 2400 Pa Design Load Test load 1 5 Front push 3600 Pa Design Load Test load 1 5...

Страница 14: ...odule meets the technical requirements of the system as a whole Ensure that other system components do not exert damaging mechanical or electrical stresses on the module When connected in series modul...

Страница 15: ...long periods Select the appropriate cable size according to its length to avoid voltage drop Connectors of different brands and models cannot be mated ATTENTION WINAICO connectors protection level is...

Страница 16: ...ialist ATTENTION High voltage direct current can occur even at low levels of radiation Never touch exposed live cables 6 3 Grounding Proper grounding on the module frames is the responsibility of the...

Страница 17: ...used only for maintaining mechanical connections and holding electrical grounding devices in the proper position for electrical conductivity Such devices where supplied with the module and evaluated...

Страница 18: ...o liability shall be borne for infringements of patent laws or other rights of third parties which result from the use of the modules unless mandated by law 9 Contacts If you have any questions our WI...

Отзывы: