background image

User’s Manual 

 

 

WIN Enterprises, Inc. 

 

Apr., 2009 

49

 

5.3 LAN Driver Installation 

PL-10600 offers the LAN driver in the setup CD.    Please click the Autorun file and 

install the driver following the procedures. 

 

1.

 

Insert the setup CD of PL-10600 into your CD-ROM drive. 

2.

 

Choose the Drivers file to click the Autorun icon. 

3.

 

Follow the procedures to finish the installation. 

 

Содержание PL-10600

Страница 1: ...anual WIN Enterprises Inc Apr 2009 1 PL 10600 Networking Appliance 1U Rack mount Intel 915GME 910GMLE Network Appliance with 8 x GbE 1 x FE CF SATA LCM User s Manual Version 1 0 sales win ent com 1 978 688 2000 ...

Страница 2: ...red trademarks of International business Machine Corporation Award is a trademark of Award Software International Inc Intel is a trademark of Intel RTL is a trademark of Realtek VIA is a trademark of VIA Technologies Inc Microsoft Windows Windows NT and MS DOS are either trademarks or registered trademarks of Microsoft Corporation All other product names mentioned herein are used for identificatio...

Страница 3: ...n Define 18 Chapter 3 Optional GbE Module Riser Card Setting 19 3 1 R 137 Ethernet module with four GbE Copper 19 Chapter 4 BIOS Setup 20 4 1 Quick Setup 20 4 2 Entering the CMOS Setup Program 21 4 3 Menu Options 22 4 4 Advanced Menu 23 4 5 PCIPnP Menu 34 4 6 Boot Menu 36 4 7 Security Menu 40 4 8 Chipset Menu 41 4 9 Power Menu 44 4 10 Exit Menu 46 Chapter 5 Utility Driver Installation 48 5 1 Opera...

Страница 4: ...our GbE Copper and max to 12 GbE Ethernet ports via PCI E by 1 or by 4 on front panel The front panel also has one FE management port one USB 2 0 port one RJ 45 console port and LED indicators that monitor power and storage device activities for local system management maintenance and diagnostics In addition the PL 10600 supports one PCI E by4 slot and is RoHS FCC and CE compliant 1 2 Specificatio...

Страница 5: ...rating 0 40 C 32 104 F Mechanical and Environment Humidity 5 95 relative humidity non operating non condensing Weight 1pc CTN 4 5kgs 55cm W x 40cm D x 20cm H Certification CE FCC 1 3 Ordering Information We offer some accessories for PL 10600 appliance for customer need PL 10600A A 1U Rackmount Intel 915GME Network System support Socket 479 CPU 8x GbE 1x FE CF SATA PCI E x8 LCM PL 10600B 060 A 1U ...

Страница 6: ...pect and make sure the packaging is intact Do not plug the power adapter to the appliance of PL 10600 if it appears damaged Note Keep the PL 10600 in the original packaging until you start installation 1 5 Precautions Please make sure you properly ground yourself before handling the PL 10600 appliance or other system components Electrostatic discharge can be easily damage the PL 10600 appliance Do...

Страница 7: ... Inc Apr 2009 7 1 6 System Layout PL 10600 Front Side PCI E slot Expansion Module optional CPU DDR2 SO DIMM Power supply CF socket 10 100 4 GbE Copper optional module USB 2 0 RJ45 Console port 4 GbE Copper 16x2 LCM 4 buttons keypad ...

Страница 8: ...User s Manual WIN Enterprises Inc Apr 2009 8 1 7 Board Dimensions ...

Страница 9: ...User s Manual WIN Enterprises Inc Apr 2009 9 Chapter 2 Connector Jumper Configuration 2 1 Connector Jumper Location and Definition ...

Страница 10: ...ufacture CN12 LCM Control Pin Header CN13 LCM Connector CN14 COM1 Connector RJ45 CN15 COM2 Pin Header CN16 FAN Connector CN17 FAN Connector CN18 FAN Connector CN19 KB MS Pin Header CN20 USB Connector Port 0 CN21 USB Pin Header Port 1 CN22 VGA Pin Header CN23 None CN24 Power Jack 12V CN25 Power Connector 2P or 4P CN26 PCI Ex8 Connector CB 7968A Only PW1 SATA HDD Power Connector CF1 CF Socket Connec...

Страница 11: ... CN2 3 4 5 6 LAN RJ 45 Connector Pin Define 1 TX 2 TX 3 RX 4 Chassis Ground 5 Chassis Ground 6 RX 7 Chassis Ground 8 Chassis Ground D2 Speed indicated LED 1 Gbps GREEN 100 Mbps YELLOW D1 Link Activity LED Link GREEN Activity BLINKING CN7 Reset Pin Header Pin Define 1 Reset 2 GND ...

Страница 12: ...Signal 1 Ground 2 TXP 3 TXN 4 Ground 5 RXN 6 RXP 7 Ground CN10 LPC Connector Pin Define Pin Define 1 3 3V 2 AD 0 3 AD 1 4 AD 2 5 AD 3 6 Frame 7 PCIRST 8 5V 9 CLOCK 10 NC 11 Ground 12 Ground CN12 LCM Control Pin Header Pin Define 1 ACK 2 BUSY 3 PE 4 SLCT 5 Ground 1 5 1 5 ...

Страница 13: ...nd 3 AFD 4 NONE 5 INIT 6 SLIN 7 PD1 8 PD0 9 PD3 10 PD2 11 PD5 12 PD4 13 PD7 14 PD6 15 BLN 16 BLP BLN BLP Backlight control via GPIO24 CN14 COM1 Connector RJ45 Pin Define 1 CTS 2 DTR 3 TXD 4 GPIO 5 Ground 6 RXD 7 DSR 8 RTS CN15 COM2 pin header Pin Define Pin Define 1 DCD 6 DSR 2 RXD 7 RTS 3 TXD 8 CTS ...

Страница 14: ...ound 10 NC CN16 17 18 FAN Connector Pin Define 1 Ground 2 12V 3 Speed Detect CN19 PS 2 KB MS Connector Pin Define Pin Define 1 KCLK 2 MCLK 3 KDAT 4 MDAT 5 Reserved 6 Not used 7 GND 8 GND 9 5V 10 5V CN20 USB Connector Port 0 Pin Define 1 USBVCC 2 USBN0 3 USBP0 4 GND ...

Страница 15: ...ED 2 GREEN 3 BLUE 4 5V 5 Ground 6 Ground 7 Ground 8 Ground 9 5V 10 Ground 11 5V 12 SDA 13 HSYNC 14 VSYNC 15 SCL 16 NC CN25 Power Connector 2P or 4P Pin Signal 1 Ground 2 Ground 3 12V 4P connector 2P connector 4 12V CN26 PCI E x8 Connector WIN proprietary connector Pin Define Pin Define B1 12V A1 GND B2 12V A2 12V B3 12V A3 12V B4 GND A4 GND B5 SMCLK A5 3 3V B6 SMDAT A6 3 3V ...

Страница 16: ... A17 RXN0 B18 GND A18 GND B19 TXP1 A19 5V B20 TXN1 A20 GND B21 GND A21 RXP1 B22 GND A22 RXN1 B23 TXP2 A23 GND B24 TXN2 A24 GND B25 GND A25 RXP2 B26 GND A26 RXN2 B27 TXP3 A27 GND B28 TXN3 A28 GND B29 GND A29 RXP3 B30 BY PASS A30 RXN3 B31 GPIO33 A31 GND B32 GND A32 GPIO34 B33 TXP4 A33 None B34 TXN4 A34 GND B35 GND A35 RXP4 B36 GND A36 RXN4 B37 TXP5 A37 GND B38 TXN5 A38 GND B39 GND A39 RXP5 B40 GND A...

Страница 17: ...GND B46 TXN7 A46 GND B47 GND A47 RXP7 B48 GPI13 A48 RXN7 B49 GND A49 GND PW1 SATA HDD Power Connector Pin Signal 1 12V 2 GND 3 GND 4 5V Jumper Setting JP1 Clear CMOS Pin Setting 1 2 Normal Default 2 3 Clear CMOS JP2 FSB CLOCK Select for CB 7968A only Pin Setting OPEN 400MHz Default CLOSE 533MHz ...

Страница 18: ...ng parts Thus it provides users with much greater protection of the data than conventional magnetic disk device Pin Assignment Pin Assignment Pin Assignment Pin Assignment Pin Assignment 1 Ground 11 Ground 21 D00 31 D15 41 RESET 2 D03 12 Ground 22 D01 32 CS 42 ORDY 3 D04 13 VCC 23 D02 33 NC 43 DREG 4 D05 14 Ground 24 WP 34 IOR 44 DACK 5 D06 15 Ground 25 NC 35 IOW 45 LED 6 D07 16 Ground 26 NC 36 WE...

Страница 19: ... match various applications and market demand 3 1 R 137 Ethernet module with four GbE Copper R 137A is a four GbE Copper module and designed reserved one pair bypass function for Option The golden edge fingers must be connected with CN26 proprietary connector of CB 7968 board Golden Edge Fingers to be connected with CN26 of CB 7968 4 x GbE Copper ports ...

Страница 20: ...s information for z Date and time z Memory capacity of the appliance z Type of display adapter installed z Number and type of disk drives The CMOS memory is maintained by battery installed on the PL 10600 board By using the battery all memory in CMOS can be retained when the system power switch is turned off The system BIOS also supports easy way to reload the CMOS data when you replace the batter...

Страница 21: ...after not having used it for a long time z Find the original setup missing z Replace the battery z Change to a different type of CPU z Run the AMI Flash program to update the system BIOS Run the CMOS Setup program after you turn on the system On screen instructions explain how to use the program Enter the CMOS Setup program s main menu as follows 1 Turn on or reboot the system After the BIOS perfo...

Страница 22: ...ve your changes and reboot the system Choosing Discard Changes and Exit ignores your changes and exits the program Pressing ESC anywhere in the program returns you to the main menu 4 3 Menu Options The main menu options of the CMOS Setup program are described in the following and the following sections of this chapter Main For changing the basic system configurations Advanced For changing the adva...

Страница 23: ...evices Use the Advanced Setup option as follows 1 Choose Advanced from the main menu The following screen appears 2 Use the arrow keys to move between fields Modify the selected field using the PgUP PgDN keys Some fields let you enter numeric values directly 3 After you have finished with the Advanced setup press the ESC key to return to the main menu ...

Страница 24: ... 24 4 4 1 CPU Configuration This sub menu shows the CPU related information which is automatically detected by BIOS 4 4 2 IDE Configuration This sub menu allow you to set or change the configurations for the IDE devices installed in the system ...

Страница 25: ...l show Not Detected if no IDE device is installed in the system Third IDE Master and Third IDE Slave This information is auto detected by BIOS and is not user configurable It will show Not Detected if no IDE device is installed in the system Fourth IDE Master and Fourth IDE Slave This information is auto detected by BIOS and is not user configurable It will show Not Detected if no IDE device is in...

Страница 26: ...occurs multiple sectors at a time if the device supports multi sector transfer feature When set to Disabled the data transfer from and to the device occurs one sector at a time PIO Mode Auto Selects the PIO mode for the device DMA Mode Auto Selects the DMA mode for the device S M A R T Auto S M A R T Self Monitoring Analysis and Reporting Technology It allows system to use the SMART protocol to mo...

Страница 27: ...ress and IRQ Serial Port2 Address 2F8 IRQ3 Selects the Serial Port2 base address and IRQ Parallel Port Address 378 Selects the Parallel Port base addresses Parallel Port Mode Normal Selects the Parallel Port mode Parallel Port IRQ IRQ7 Selects the Parallel Port IRQ Watch Dog Timer Select Disabled Enables or disables the WatchDog Time out ...

Страница 28: ...Inc Apr 2009 28 4 4 4 Hardware Health Configuration This screen shows you the CPU core voltage System voltage System temperature and CPU temperature 4 4 5 ACPI Configuration This sub menu is used to change the settings for the ACPI ...

Страница 29: ...ystem Advanced ACPI Configuration This sub menu configures additional ACPI options It contains below sub menus ACPI 2 0 Features No This item allows you to enable or disable RSPD pointers to 64 bit Fixed System Description Tables ACPI APIC support Enabled This item allows you to enable or disable APIC features ...

Страница 30: ...rises Inc Apr 2009 30 Chipset ACPI Configuration This sub menu configures the south bridge ACPI configuration It contains below sub menus 4 4 6 Event Log Configuration This sub menu allows you to view the event logging details ...

Страница 31: ... WIN Enterprises Inc Apr 2009 31 4 4 7 MPS Configuration This sub menu allows you to select MPS Revision 4 4 8 PCI Express Configuration This sub menu allows you to enable or disable the PCI Express link power state ...

Страница 32: ...Serial Port Mode 115200 8 n 1 This item allows you to select serial port settings Flow Control None This item allows you to select flow control for console redirection Redirection After BIOS POST Always This item allows you to set Redirection configuration after BIOS POST Always The console redirection is always active Boot Loader The console redirection is active during POST and Boot Loader Disab...

Страница 33: ...y This item allows you to set the delay in seconds to display memory information 4 4 10 USB Configuration This sub menu allows you to change the USB related features Legacy USB Support Auto Enables support for legacy USB AUTO option disables legacy support if no USB devices are connected USB 2 0 Controller Mode HiSpeed This item allows you to configure the USB 2 0 controller in HiSpeed 480Mbps or ...

Страница 34: ...F1 Help key for information on the available options 3 After you have finished with the PCIPnP Setup press the ESC key to return to the main menu Plug Play O S No No lets the BIOS configure all the devices in the system Yes lets the OS configure Plug Play devices not required for boot if your system has a Plug Play operating system PCI Latency Timer 64 This item allows you to select the value in u...

Страница 35: ...s the PCI devices that an ISA graphics device is installed in the system so that the device can function correctly PCI IDE BusMaster Enabled This item allows you to enable or disable the feature Enable BIOS uses PCI bus mastering for reading writing to IDE devices Reserved Memory Size 32K This is to set the size of memory block to be reserved for legacy USB devices Reserved Memory Address C0000 Th...

Страница 36: ...oot from the main menu The following screen appears 2 Move between items and select values by using the arrow keys Modify the selected fields using the PnUP PgDN Keys For information on the various options press F1 key 3 After you have finished with the Boot setup press the ESC key to return to the main menu ...

Страница 37: ...e time needed to boot the system Quiet Boot Disabled This item allows you to enable or disable the full screen logo display feature Disabed displays normal POST messages AddOn ROM Display Mode Force BIOS Allows you to set the display mode for option ROM Bootup Num Lock On Allows you to select the Power on state for the Num Lock Wait For F1 If Error Enabled Waits for F1 key to be pressed if error o...

Страница 38: ...d Lan Boot ROM Disabled This item allows you to enable or disable the Onboard Lan Boot function 4 6 2 Boot Device Priority 1st Boot Device HDD SM TRANSCEND This item allows you to set the boot priority Specifies the boot sequence from the available devices A device enclosed in parenthesis has been disabled in the corresponding type menu ...

Страница 39: ...User s Manual WIN Enterprises Inc Apr 2009 39 4 6 3 Hard Disk Drives 1st Drive HDD SM TRANSCEND This item is used to specify the boot sequence from available devices ...

Страница 40: ...s options 3 After you have finished with the Security setup press the ESC key to return to the main menu Change Supervisor Password This item allows you to set or change the supervisor password The Supervisor Password item on top of the screen shows the default Not Installed After you have set a password this item shows Installed Change User Password This item allows you to set or change the user ...

Страница 41: ...s or program attempts to write to the hard disk s boot sector or attempts to execute disk format command 4 8 Chipset Menu Use the Chipset Setup option as follows 1 Choose Chipset from the main menu The following screen appears 2 Move between items and select values by using the arrow keys Modify the selected field the PgUP PgDN keys For information on the various options press F1 key 3 After you h...

Страница 42: ...AM Timing by SPD Enabled This item allows you to enable or disable the feature Enabled The DRAM timing parameters are set according to the DRAM SPD Disabled You can manually set the DRAM timing parameters Memory Hole Disabled This item allows you to enable or disable the memory hole Boots Graphic Adapter Priority PEG PCI This item shows the primary graphic adapter Internal Graphics Mode Select Ena...

Страница 43: ...ate control for AC power loss recovery When set to Power On the system goes on after an AC power loss When set to Power Off the system goes into off state after an AC power loss When set to Last State the system goes into either on or off state whatever was the system state before the AC power loss PCI EX Ports Configuration PCI Express Port 1 Enable PCI Express Port 2 Enable PCI Express Port 3 En...

Страница 44: ...DN keys Please press the F1 key for information on the various options 3 After you have finished with the Power setup press the ESC key to return to the main menu Power Management APM Enabled This item allows you to enable or disable the APM Advanced Power Management feature Power Savings Under AC Disabled This item allows you to enable or disable the Power Savings Under AC Power Savings Level Dis...

Страница 45: ... item allows you to enable or disable the USB Controller Resume This function allows you press any key USB keyboard to wake up the system from S3 state PME Resume Disabled Allows you to enable or disable the PME Power Management Event Resume When setting to Enabled this setting allows your system to be awakened from the power saving modes through any event on PCI PME RI Resume Disabled Allows you ...

Страница 46: ...etween items and select values by using the arrow keys Modify the selected fields using the PgUP PgDN keys For information on the various options please press F1 key 3 Please press the ESC key to return the main menu after finishing with the Exit Options Save Changes and Exit Save changes of values to CMOS and exit the CMOS setup program F10 key can be used for this operation Discard Changes and E...

Страница 47: ... allows you to load optimal defaults for each of the parameters on the Setup menus which will provide the best performance settings for your system F9 key can be used for this operation Load Failsafe Defaults This item allows you to load failsafe defaults for each of the parameters on the Setup menus which will provide the most stable performance settings F8 key can be used for this operation ...

Страница 48: ...0 can support Windows and Linux operation system as follows Before installation please check your OS version If your OS is not in the following list please upgrade your OS version OS Version DOS DOS 6 22 Windows Windows XP Professional SP2 SP3 Linux Kernel 2 6 21 1 3794 Fedora Core 7 5 2 System Driver Installation PL 10600 offers the system driver in the setup CD Please install the driver followin...

Страница 49: ...0600 offers the LAN driver in the setup CD Please click the Autorun file and install the driver following the procedures 1 Insert the setup CD of PL 10600 into your CD ROM drive 2 Choose the Drivers file to click the Autorun icon 3 Follow the procedures to finish the installation ...

Страница 50: ...imer interval to the controller The value range is from 01H to FFH and the related time watchdog timer interval is 1 sec to 255 sec Data Timer interval 00 Disabled 01 1 sec 02 2 sec FF 255 sec If you want to disable the watchdog timer just set the timer interval value to 00H After setting the timer interval value the watchdog timer begins to count down You have to refresh the watchdog timer so tha...

Страница 51: ... 2EH MOV AL 07H OUT DX AL MOV DX 2FH MOV AL 08H OUT DX AL MOV DX 2EH MOV AL 30H OUT DX AL MOV DX 2FH MOV AL 01H OUT DX AL O 2E 07 O 2F 08 O 2E 30 O 2F 01 Program 2 Writing a watchdog timer interval value MOV DX 2EH Set timer interval value to xx seconds MOV AL F6H OUT DX AL MOV DX 2FH MOV AL XXH Timer interval see note OUT DX AL MOV DX 2EH MOV AL AAH OUT DX AL O 2E F6 O 2F XX O 2E AA ...

Страница 52: ...L AAH OUT DX AL O 2E F6 O 2F 00 O 2E AA Note This XX value range is from 01H to FFH and the related watchdog timer interval is 1 sec to 255 sec as in the previous description Using the Demo Program Update the System BIOS as follows 1 Run Program 1 2 Run Program 2 load the timer interval of 1EH 30 seconds 3 Run your Application Program 1 Be sure your Application Program will finish within 30 second...

Страница 53: ...ity included in Windows directory to see their map IRQ Assignment IRQ0 Timer IRQ1 Keyboard IRQ2 Interrupt rerouting from IRQ8 through IRQ15 IRQ3 COM2 IRQ4 COM1 IRQ5 Sound Card IRQ6 FDD Controller IRQ7 LPT1 IRQ8 RTC IRQ9 USB Controller IRQ10 Multimedia Audio IRQ11 VGA Adapter IRQ12 Mouse IRQ13 Coprocessor IRQ14 IDE Controller IRQ15 IDE Controller DMA Channel Assignment Channel 4 is by default used ...

Страница 54: ...09FC00 00000000 00000400 Reserved 00000000 000F0000 00000000 00010000 Reserved 00000000 FEC00000 00000000 01400000 Reserved 00000000 00100000 00000000 07EF0000 Available 00000000 07FF3000 00000000 0000D000 ACPI Space 00000000 07FF0000 00000000 00003000 NVS Space Address Range Type Owner A0000 AFFFF ISA VGA Adapter B0000 BFFFF ISA VGA Adapter C0000 C79FF ISA Adapter ROM F0000 FFFFF ISA System BIOS ...

Страница 55: ...81 83 AT DMA controller 87 AT DMA controller 89 8B AT DMA controller 8F 91 AT DMA controller A0 A1 AT interrupt controller C0 DF AT DMA controller F0 FF Math Coprocessor 170 177 IDE Controller 1F0 1F7 IDE Controller 200 207 Game port 220 22E Sound Card 2F8 2FF COM2 376 IDE Controller 378 37A LPT1 3B0 3BB VGA Adapter 3C0 3DF VGA Adapter 3F0 3F5 FDD Controller 3F6 IDE Controller 3F7 FDD Controller 3...

Страница 56: ...al WIN Enterprises Inc Apr 2009 56 6000 607F MB Resource D000 D00E IDE Controller D400 D41E USB Controller D800 D81E USB Controller DC00 DCFE Multimedia Audio EC00 E002 Multimedia Audio E400 E402 Multimedia Audio ...

Страница 57: ...rnet Cat 5 Cable 2M RoHS CB EC5200 00 1 Cross Over 2M Color RoHS CB CO5202 4 00 1 RJ45 to DB9 2M Cable RoHS CB RJDB91 00 1 2m null modem cable RoHS CB DB9200 01 1 VGA CABLE 2mm 15CM RoHS CB IVGA01 00 1 KB MS CABLE 15CM RoHS CB IPS200 00 1 USB CABLE w Bracket RoHS CB IUSB2B 00 1 CB EC5200 00 CB CO5202 4 00 CB RJDB91 00 CB DB9200 00 CB IVGA01 00 CB IPS200 00 CB IUSB2B 00 ...

Отзывы: