WIN Enterprises PL-80610 Скачать руководство пользователя страница 23

                                                                               

Copyright © 2014 

WIN Enterprises, Inc. All Rights Reserved.

                                                                  Aug., 2014

                   

     

WIN Enterprises User’s Manual 

    

 

 

2.3 CompactFlash

TM

 Card Socket Pin Definitions 

 

CompactFlash

TM

 card is a small removable mass storage device. It can provide complete 

PCMCIA-ATA functionality and compatibility plus True IDE functionality compatible with 

ATA/ATAPI-4. 

CompactFlash

TM

 storage products are solid state form factor, it means they contain no moving parts. 

Thus, it provides users with much greater protection of the data than conventional magnetic disk 

device. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pin 

Assignment  Pin 

Assignment  Pin 

Assignment  Pin 

Assignment  Pin 

Assignment 

Ground 

11 

Ground 

21 

D00 

31 

D15 

41 

RESET 

D03 

12 

Ground 

22 

D01 

32 

CS 

42 

ORDY 

D04 

13 

VCC 

23 

D02 

33 

NC 

43 

DREG 

D05 

14 

Ground 

24 

WP 

34 

IOR 

44 

DACK 

D06 

15 

Ground 

25 

NC 

35 

IOW 

45 

LED 

D07 

16 

Ground 

26 

NC 

36 

WE 

46 

BVD 

CS 

17 

Ground 

27 

D11 

37 

RDY/BSY 

47 

D08 

Ground 

18 

A02 

28 

D12 

38 

VCC 

48 

D09 

Ground 

19 

A01 

29 

D13 

39 

SCSE 

49 

D10 

10 

Ground 

20 

A00 

30 

D14 

40 

NC 

50 

Ground 

23

 

Содержание PL-80610

Страница 1: ...Network Appliance PL PL PL PL 80610 80610 80610 80610 User s Manual www win ent com Copyright 2014 WIN Enterprises Inc All Rights Reserved Version 1 0...

Страница 2: ...of Award Software International Inc Intel is a trademark of Intel RTL is a trademark of Realtek VIA is a trademark of VIA Technologies Inc Microsoft Windows Windows NT and MS DOS are either trademark...

Страница 3: ...2 Connector and Jumper Setting 11 2 3 CompactFlashTM Card Socket Pin Define 22 Chapter 3 BIOS Setup 23 3 1 Quick Setup 23 3 2 Entering the CMOS Setup Program 23 3 3 Menu Options 26 3 4 Advanced Menu...

Страница 4: ...ash thus granting the best network performance and maximum utilization In order to enhance network security performance the PL 80610 offers optional Intel Quick Assist technology that provides hardwar...

Страница 5: ...t Ethernet LAN bypass 2 pairs bypass SATA HDD One internal SATA connector and One 4 pin power connector for HDD Storage Storage Storage Storage Compact Flash Socket one CompactFlashTM Type II USB Two...

Страница 6: ...ter you unpack the goods inspect and make sure the packaging is intact Do not plug the power adapter to the appliance of PL 80610 if it is perceived to be damaged Note Keep the PL 80610 in the origina...

Страница 7: ...tatic discharge can be easily damage the PL 80610 appliance Do not remove the anti static packing until you are ready to install the PL 80610 appliance Ground yourself before removing any system compo...

Страница 8: ...Copyright 2014 WIN Enterprises Inc All Rights Reserved Aug 2014 WIN Enterprises User s Manual 1 6 System Layout PL 80610 Front Side Layout PL 80610 Rear Side Layout...

Страница 9: ...Copyright 2014 WIN Enterprises Inc All Rights Reserved Aug 2014 WIN Enterprises User s Manual 1 7 Board Dimensions 9...

Страница 10: ...Copyright 2014 WIN Enterprises Inc All Rights Reserved Aug 2014 WIN Enterprises User s Manual Chapter 2 Connector Jumper Configuration 2 1 Connector Jumper Location and Definition 10...

Страница 11: ...r PCIE slot CN4 Keypad connector JP4 LAN3 LAN4 bypass select CN6 LCM connector JP5 LAN1 LAN2 bypass select CN7 Power on off GPIO Connector JP6 GPI or reset select CN8 KB MS Connector JP7 WDT LAN bypas...

Страница 12: ...l Rights Reserved Aug 2014 WIN Enterprises User s Manual 2 2 Connector and Jumper Settings CN1 COM2 connector CN2 SATA Power Pin Signal 1 DCD 2 RXD 3 TXD 4 DTR 5 Ground 6 DSR 7 RTS 8 CTS 9 RI 2 10 N A...

Страница 13: ...ed Aug 2014 WIN Enterprises User s Manual CN7 SATA Connector CN7 GPIO Connector Pin Define Pin Define 1 3 3V 2 GND 3 GPIO30 4 GPIO31 5 GPIO32 6 GPIO33 7 GPIO34 8 GPIO35 9 GPIO36 10 GPIO37 Pin Signal 1...

Страница 14: ...prises User s Manual CN6 KB MS Pin Headers Pin Define Pin Defined 1 KCLK 2 MCLK 3 KDAT 4 MDAT 5 N A 6 N A 7 PS2_GND 8 PS2_GND 9 PS2_VCC 10 PS2_VCC CN11 USB Connector Pin Define Pin Defined 1 3 3V 2 AD...

Страница 15: ...served Aug 2014 WIN Enterprises User s Manual CN12 LPC Connector Pin Define Pin Defined 1 3 3V 2 AD0 3 AD1 4 AD2 5 AD3 6 Frame 7 PCIRST 8 5V 9 CLOCK 10 N A 11 GND 12 GND CN13 GPI Connector Pin Define...

Страница 16: ...ved 11 REFCLK 12 Reserved 13 REFCLK 14 Reserved 15 GND 16 Reserved 17 Reserved 18 GND 19 Reserved 20 Reserved 21 GND 22 PERST 23 PERN0 24 3 3VAUX 25 PERP0 26 GND 27 GND 28 1 5V 29 GND 30 SMB_CLK 31 PE...

Страница 17: ...ll Rights Reserved Aug 2014 WIN Enterprises User s Manual CN17 USB RJ45 Connector Pin Define Pin Defined 1 5V 2 DATA0 3 DATA0 4 GND 5 5V 6 DATA1 7 DATA1 8 GND RJ45 Console COM1 Pin Defined 1 CTS 2 DTR...

Страница 18: ...erprises User s Manual CN19 Reset Connector CN21 CN24 LAN1 LAN8 Connector Pin Defined 1 Ground 2 Reset Pin Defined 1 MDI0 2 MDI0 3 MDI1 4 MDI2 5 MDI2 6 MDI1 7 MDI3 8 MDI3 D2 Link Activity LED Link Gre...

Страница 19: ...nc All Rights Reserved Aug 2014 WIN Enterprises User s Manual CN25 2 Pin Power Connector CN26 DC Jack 1000Mbps Yellow Pin Define Pin Defined 1 12V 2 GND Pin Define Pin Defined 1 12V 2 GND Jumper Setti...

Страница 20: ...eserved Aug 2014 WIN Enterprises User s Manual 1 2 Normal Operation Default 2 3 Clear CMOS Jumper Setting JP2 DDR power select 1 5V 1 35V Pin Setting 1 2 DDR Power 1 5V Default 2 3 DDR Power 1 35V Jum...

Страница 21: ...Rights Reserved Aug 2014 WIN Enterprises User s Manual 1 2 Bypass mode 2 3 Disable mode Default Jumper Setting JP5 LAN1 LAN2 Bypass Pin Setting 1 2 Bypass mode 2 3 Disable mode Default Jumper Setting...

Страница 22: ...ght 2014 WIN Enterprises Inc All Rights Reserved Aug 2014 WIN Enterprises User s Manual 1 2 GPI Input 2 3 Reset Default Jumper Setting JP7 WDT LAN bypass select Pin Setting 1 2 WDT Default 2 3 LAN byp...

Страница 23: ...ans they contain no moving parts Thus it provides users with much greater protection of the data than conventional magnetic disk device Pin Assignment Pin Assignment Pin Assignment Pin Assignment Pin...

Страница 24: ...acity of the appliance Type of display adapter installed Number and type of disk drives The CMOS memory is maintained by a battery installed on the PL 80610 board By using the battery all memory in CM...

Страница 25: ...the original setup missing Replace the battery Change to a different type of CPU Run the AMI Flash program to update the system BIOS Run the CMOS Setup program after you turn on the system On screen...

Страница 26: ...lowing sections for a brief description of each setup option AMI BIOS Displays the auto detected BIOS information Processor Displays the auto detected CPU specification System Memory Displays the auto...

Страница 27: ...d in the following and the following sections of this chapter Main For changing the basic system configurations Advanced For changing the advanced system settings Chipset For changing the chipset sett...

Страница 28: ...tween fields Modify the selected field using the PgUP PgDN keys Some fields let you enter numeric values directly 3 After you have finished with the Advanced setup press the ESC key to return to the m...

Страница 29: ...Aug 2014 WIN Enterprises User s Manual 3 4 2 IDE Configuration This sub menu allow you to set or change the configurations for the IDE devices installed in the system 3 4 3 USB Configuration This sub...

Страница 30: ...s Reserved Aug 2014 WIN Enterprises User s Manual 3 4 4 Hardware Health Configuration This screen shows you the CPU core voltage System voltage System temperature and CPU temperature System Temperatur...

Страница 31: ...rises User s Manual CPU Temperature These read only fields show the functions of the hardware thermal sensor by CPU thermal diode that monitors the chip blocks to ensure a stable system Vcore 12V 5V 3...

Страница 32: ...selected fields using the PnUP PgDN Keys For information on the various options press F1 key 3 After you have finished with the Boot setup press the ESC key to return to the main menu Setup Prompt Tim...

Страница 33: ...g screen appears 2 Move between items and select values by using the arrow keys Modify the selected fields using the PgUP PgDN keys Please press the F1 key for information on the various options After...

Страница 34: ...ollows 1 Choose Chipset Configuration from the Advanced menu The following screen appears 2 Move between items and select values by using the arrow keys Modify the selected field the PgUP PgDN keys Fo...

Страница 35: ...screen appears 2 Move between items and select values by using the arrow keys Modify the selected fields using the PgUP PgDN keys For information on the various options please press F1 key 3 Please pr...

Страница 36: ...L 80610 can support Windows and Linux operation system as follows Before installation please check your OS version If your OS is not in the following list please upgrade your OS version OS Version DOS...

Страница 37: ...tem Description Part No Qty Ethernet Cat 5 Cable 2M RoHS CB EC5200 00 1 Cross Over 2M Color RoHS CB CO5202 4 00 1 RJ45 to DB9 2M Cable RoHS CB RJDB91 00 1 Null modem cable 2M CB DB9200 01 1 KB MS cabl...

Отзывы: