WIN Enterprises PL-80160 Скачать руководство пользователя страница 1

User’s Manual 

 

 

WIN Enterprises, Inc. 

 

Sept., 2010 

1

 

 

 

 

User’s Manual 

Version 1.0 

 

PL-80160 Networking Appliance 

2U Rack-Mount Intel® 3450 LGA1156 Network System, 32 x 
GbE, SATA, CF, LCM, PCI, PCI-Ex8, Redundant PS 

 

 

 

 

 

 

 

 

 

 

 

[email protected] 

 

 

Содержание PL-80160

Страница 1: ...Manual WIN Enterprises Inc Sept 2010 1 User s Manual Version 1 0 PL 80160 Networking Appliance 2U Rack Mount Intel 3450 LGA1156 Network System 32 x GbE SATA CF LCM PCI PCI Ex8 Redundant PS sales win e...

Страница 2: ...trademarks of International business Machine Corporation Award is a trademark of Award Software International Inc Intel is a trademark of Intel RTL is a trademark of Realtek VIA is a trademark of VIA...

Страница 3: ...ing 12 2 3 CompactFlashTM Card Socket Pin Define 21 Chapter 3 BIOS Setup 19 3 1 Quick Setup 19 3 2 Entering the BIOS Setup Utility 35 3 3 Menu Options 361 3 4 Advanced Menu 372 3 5 Boot Menu 32 3 6 Se...

Страница 4: ...verall system throughput performance This platform affords 8 GbE and max to 32 GbE Ethernet ports via PCI E by8 on the front panel To prevent network problems when the platform shuts down PL 80160 sup...

Страница 5: ...rt COM1 One internal 5x2 header for second console COM2 Power Supply Watt 2U ATX 350W Redundant Power Supply Form Factor 2U rack mount LCD Module One 16x2 LCM Keypad Four buttons keypad LED One Power...

Страница 6: ...PCI PCI E x8 Redundant PS Bypass PL 8016A SBCA R122A PL 80160B 2U Rackmount Intel 3450 LGA1156 Network System 6 RJ45 GbE 6 SFP LCM PCI PCI E x8 Redundant PS Bypass PL 8016A SBC IP 9061A PL 80160C 2U R...

Страница 7: ...goods inspect and make sure the packaging is intact Do not plug the power cord to the PL 80160 appliance if you already find it appears damaged Note Keep the PL 80160 in the original packaging until...

Страница 8: ...ser s Manual WIN Enterprises Inc Sept 2010 8 1 6 System Layout PL 80160 Front Side PL 80160 Rear Side HDD Bay optional CPU DDR3 DIMM Socket CF Socket PCIe slot for Ethernet module PCI slot Power Suppl...

Страница 9: ...User s Manual WIN Enterprises Inc Sept 2010 9 1 7 Board Dimensions...

Страница 10: ...User s Manual WIN Enterprises Inc Sept 2010 10 Chapter 2 Connector Jumper Configuration 2 1 Connector Jumper Location and Definition...

Страница 11: ...onnector CN9 ATX Power Connector CN31 Gigabit Ethernet RJ 45 Connector CN10 4 Pin Power Connector CN32 Gigabit Ethernet RJ 45 Connector CN12 LPC Pin Header CN33 PCI E x8 Golden Finger CN13 GPI Pin Hea...

Страница 12: ...AN Connector CN8 CPU FAN Connector Pin Define 1 Ground 2 12V 3 Speed Detect CN3 12V Power Connector Pin Define Pin Define 1 GND 5 12V 2 GND 6 12V 3 GND 7 12V 4 GND 8 12V CN9 ATX Power Connector Pin De...

Страница 13: ...Ground 18 RSVD 8 POWER GOOD 19 5V 9 5VSB 20 5V 10 12V CN10 Power Connector Pin Define 1 12V 2 GND 3 GND 4 VCC5 CN12 LPC Pin Header Pin Define Pin Define 1 3 3V 2 LAD0 3 LAD1 4 LAD2 5 LAD3 6 LFRAME 7 R...

Страница 14: ...Box Header Pin Define Pin Define 1 STROBE 14 AUTOFD 2 PD0 15 ERR 3 PD1 16 INT 4 PD2 17 SLCTIN 5 PD3 18 Ground 6 PD4 19 Ground 7 PD5 20 Ground 8 PD6 21 Ground 9 PD7 22 Ground CN15 PS 2 KB MS Pin Header...

Страница 15: ...x Header 2 0mm pitch Pin Define Pin Define 1 RSTPIDE 2 Ground 3 PDD7 4 PDD8 5 PDD6 6 PDD9 7 PDD5 8 PDD10 9 PDD4 10 PDD11 11 PDD3 12 PDD12 13 PDD2 14 PDD13 15 PDD1 16 PDD14 17 PDD0 18 PDD15 19 Ground 2...

Страница 16: ...er ON System Reset Pin Header Pin Define Pin Define 1 POWER ON 2 POWER ON 3 GND 4 RESET CN23 USB LED Box Header Pin Define Pin Define 1 5V 2 5V 3 USB_P1 4 USB_P0 5 USB_P1 6 USB_P0 7 GND 8 GND 9 N C 10...

Страница 17: ...efine 1 GPO4 2 Ground 3 GPO5 4 Ground 5 GPO6 6 Ground 7 GPO7 8 Ground 9 Ground 10 5V CN26 CN27 CN28 CN29 CN31 CN32 Gigabit Ethernet RJ 45 Connector Pin Define 1 TX 2 TX 3 RX 4 Chassis Ground 5 Chassis...

Страница 18: ...Define STD 1 CTS 2 DTR 3 TXD 4 GND 5 Ground 6 RXD 7 DSR 8 RTS CF1 CF Socket Please refer to the Ch 2 3 CompactFlashTM Card Socket Pin Define VGA1 VGA Box Header Pin Define Pin Define 1 RED 2 GREEN 3...

Страница 19: ...n Setting 1 2 ATX Mode Default 2 3 Auto Power On Mode JP4 Watchdog Function Selection Pin Setting 1 2 Lan Bypass 2 3 H W Reset JP5 Clear CMOS Pin Header Pin Setting 1 2 Normal Default 2 3 Clear CMOS J...

Страница 20: ...s Manual WIN Enterprises Inc Sept 2010 20 JP8 LAN 3 4 Bypass Selection Pin Setting 1 2 Normal Default 2 3 Bypass Always Disable JP5 GPI or H W Reset Selection for SW1 Button Pin Setting 1 2 GPI 2 3 R...

Страница 21: ...ng parts Thus it provides users with much greater protection of the data than conventional magnetic disk device Pin Assignment Pin Assignment Pin Assignment Pin Assignment Pin Assignment 1 Ground 11 G...

Страница 22: ...ications and market demand 3 1 IP 9060A Ethernet module with two GbE Copper and two GbE SFP IP 9060A is a two GbE Copper and two GbE SFP Ethernet module The golden edge fingers must be connected with...

Страница 23: ...net module with four GbE SFP IP 9061A is a four GbE SFP Ethernet module The golden edge fingers must be connected with CN21 proprietary connector of PL 80160 board 4 x GbE SFP ports Golden Edge Finger...

Страница 24: ...function for optional ODM project The golden edge fingers must be connected with CN21 proprietary connector of PL 80160 board The alternative IP 9062A is a two GbE SFP Ethernet module Picture 1 IP 906...

Страница 25: ...le with four GbE Copper IP 9063A is a four GbE Copper Ethernet module The golden edge fingers must be connected with CN21 proprietary connector of PL 80160 board Golden Edge Fingers must be connected...

Страница 26: ...thernet module with eight GbE Copper IP 9064A is a Eight GbE Copper Ethernet module The golden edge fingers must be connected with CN21 proprietary connector of PL 80160 board Golden Edge Fingers must...

Страница 27: ...5A Ethernet module with eight GbE SFP IP 9065A is an Eight GbE SFP Ethernet module The golden edge fingers must be connected with CN21 proprietary connector of PL 80160 board Golden Edge Fingers must...

Страница 28: ...dule with four GbE Copper and bypass R168 is a four GbE Copper Ethernet module with bypass The golden edge fingers must be connected with CN21 proprietary connector of PL 80160 board Golden Edge Finge...

Страница 29: ...R169 Ethernet module with four GbE SFP R169 is a four GbE SFP Ethernet module The golden edge fingers must be connected with CN21 proprietary connector of PL 80160 board Golden Edge Fingers must be co...

Страница 30: ...thernet module with eight GbE Copper R171 is an eight GbE Copper Ethernet module The golden edge fingers must be connected with CN21 proprietary connector of PL 80160 board Golden Edge Fingers must be...

Страница 31: ...dule with four GbE Copper and bypass R175 is a four GbE Copper Ethernet module with bypass The golden edge fingers must be connected with CN21 proprietary connector of PL 80160 board Golden Edge Finge...

Страница 32: ...GbE Copper four GbE SFP R186 is a four GbE Copper and four GbE SFP Ethernet module with bypass The golden edge fingers must be connected with CN21 proprietary connector of PL 80160 board Golden Edge F...

Страница 33: ...88 Ethernet module with two 10GbE SFP R188 is a two 10GbE SFP Ethernet module The golden edge fingers must be connected with CN21 proprietary connector of PL 80160 board Golden Edge Fingers must be co...

Страница 34: ...s information for z Date and time z Memory capacity of the appliance z Type of display adapter installed z Number and type of disk drives The CMOS memory is maintained by battery installed on the PL 8...

Страница 35: ...fter not having used it for a long time z Find the original setup missing z Replace the battery z Change to a different type of CPU z Run the AMI Flash program to update the system BIOS Run the BIOS S...

Страница 36: ...e main menu press F10 Save Changes and Exit to save your changes and reboot the system Choosing Discard Changes and Exit ignores your changes and exits the program Pressing ESC anywhere in the program...

Страница 37: ...vices Use the Advanced Setup option as follows 1 Choose Advanced from the main menu The following screen appears 2 Use the arrow keys to move between fields Modify the selected field using the PgUP Pg...

Страница 38: ...lization Tech Enabled Enabled Allows legacy OSes to boot even without support for CPUs with extended cPUID functions Disabled Disable this function Execute Disable Bit Capability Enabled Enabled Enabl...

Страница 39: ...the system Primary Secondary Third Fourth IDE Master This information is auto detected by BIOS and is not user configurable It will show Not Detected if no IDE device is installed in the system Prima...

Страница 40: ...enables the LBA mode if the device supports this mode and if the device was not previously formatted with LBA mode disabled Block Multi Sector Transfer Auto Enables or disables the Block Multi Sector...

Страница 41: ...toring Analysis and Reporting Technology It allows system to use the SMART protocol to monitor your hard disk status 32Bit Data Transfer Disabled Enables or disables 32 bit data transfer If the host c...

Страница 42: ...ses Inc Sept 2010 42 4 4 3 Super IO Configuration This sub menu allows you to set or change the configurations for Super I O function Parallel Port Address 378 Selects the Parallel Port base addresses...

Страница 43: ...le or disable the LAN bypass function when Power Off Power On Bypass Disabled This item allows you to enable or disable the LAN bypass function when Power On Please refer to the Appendix B for LAN Byp...

Страница 44: ...Sept 2010 44 4 4 4 Hardware Health Configuration This screen shows you the CPU core voltage System voltage System temperature and CPU temperature 4 4 5 Event Log Configuration This sub menu allows you...

Страница 45: ...elected port is enabled Base Address IRQ 3F8h 4 Serial Port Mode 115200 8 n 1 This item allows you to select serial port settings Flow Control None This item allows you to select flow control for cons...

Страница 46: ...for ANSI VT100 terminals Sredir Memory Display Delay No Delay This item allows you to set the delay in seconds to display memory information 4 4 7 USB Configuration This sub menu allows you to change...

Страница 47: ...or USB keyboards and mice It is also useful in providing USB keyboard and mouse support in Windows NT which does not natively support USB USB 2 0 Controller Mode HiSpeed This item allows you to config...

Страница 48: ...Boot Setup option as follows 1 Choose Boot from the main menu The following screen appears 2 Move between items and select values by using the arrow keys Modify the selected fields using the PnUP PgD...

Страница 49: ...w sub menus Quick Boot Enabled This item allows BIOS to skip certain tests POST Power On Self Tests while booting This will decrease the time needed to boot the system Hit DEL Message Display Enabled...

Страница 50: ...0 4 5 2 Boot Device Priority 1st Boot Device HDD SM TRANSCEND This item allows you to set the boot priority Specifies the boot sequence from the available devices A device enclosed in parenthesis has...

Страница 51: ...User s Manual WIN Enterprises Inc Sept 2010 51 4 5 3 Hard Disk Drives 1st Drive HDD SM TRANSCEND This item is used to specify the boot sequence from available devices...

Страница 52: ...keys Please press the F1 key for information on the various options 3 After you have finished with the Security setup press the ESC key to return to the main menu Change Supervisor Password This item...

Страница 53: ...m allows you to clear the user password Boot Sector Virus Protection Disabled This item allows you to enable or disable the boot sector virus protection If enabled AMI BIOS will issue a warning when a...

Страница 54: ...he Chipset Setup option as follows 1 Choose Chipset from the main menu The following screen appears 2 Move between items and select values by using the arrow keys Modify the selected field the PgUP Pg...

Страница 55: ...s Manual WIN Enterprises Inc Sept 2010 55 4 7 1 NorthBridge VIA VX800 Configuration This sub menu allows you to change the AGP P2P features 3 7 1 1 AGP P2P Bridge Configuration Primary Graphic Adapter...

Страница 56: ...PCI slot you can select this item AGP This item is to use the internal graphic controller OnChip VGA of North Bridge to be primary graphic adapter 4 7 1 1 1 OnChip VGA Configuration This sub menu allo...

Страница 57: ...A GenI II control in automatic or Gen I II SATA Partial Control Disabled This item allows you to enable or disable the SATA Partial Control SATA Slumber Control Disabled This item allows you to enable...

Страница 58: ...ve between items and select values by using the arrow keys Modify the selected field the PgUP PgDN keys For information on the various options press F1 key 3 After you have finished with the Exit pres...

Страница 59: ...llows you to load optimal defaults for all settings on the BIOS Setup menus and it will provide the best performance settings for system F9 key can be used for this operation Load Failsafe Defaults Th...

Страница 60: ...your OS is not in the following list please upgrade your OS version OS Version Windows Windows XP 32bit 64bit SP2 Windows XP 32bit 64bit SP3 Windows Server 2003 Windows Server 2008 Windows 7 32bit 64...

Страница 61: ...for Windows operation system that is listed above in the setup CD Please click the Autorun file and install the driver following the procedures 1 Insert the setup CD of PL 80160 into your CD ROM driv...

Страница 62: ...chdog Timer The WIN PL 80160 provides a watchdog timer that can reset the system or activate LAN bypass function It provides the following function for user programming Can be enabled and disabled by...

Страница 63: ...isable the WDTO output low pulse to KBRST 0 Disable 1 Enable CRF6 R W Watchdog time out value 0 stop timer default 01 FFh Writing a non zero value to this register causes the counter to load the value...

Страница 64: ...X AL OUT DX AL Configure logical device 8 MOV AL 07H OUT DX AL Point to Logical Device Number Reg INC DX MOV AL 08H OUT DX AL Select logical device 8 Set second as counting unit and KBRST time out eve...

Страница 65: ...ime out event to control LAN by pass or activate hardware reset through JP4 Please refer to jumper setting section for more detail information Enter the extended function mode interruptible double wri...

Страница 66: ...H OUT DX AL Set Watchdog time our to minute mode Load 2 minutes to Watchdog Counter and start counting down DEC DX MOV AL F6H OUT DX AL Select CRF6 INC DX MOV AL 02H OUT DX AL Time out occurs after 2...

Страница 67: ...on between CN28 CN29 and CN31 CN32 LAN ports on motherboard Refer to Page 10 The BIOS Power on off Bypass settings control the bypass function through GPIO pins End 1 LAN Bypass Definition There are t...

Страница 68: ...User s Manual WIN Enterprises Inc Sept 2010 68 Power on Bypass Enable Note Note Before you want to set this item the Power off Bypass must set to Enable...

Страница 69: ...follow below steps to set the LAN bypass function control by watchdog timer 1 Setup jumper JP6 to 2 3 shorted to enable bypass function when watchdog timer time out 2 Refer to watchdog timer section t...

Страница 70: ...R W R W Read Write X Not used Bit 2 0 101 Set bypass to disable when power on 010 Set bypass to enable when power on Please follow below steps to set the LAN bypass function control by GPIO 1 Set jump...

Страница 71: ...Bypass enabled when power on MOVDX 02EH MOVAL 07H Logic Device 7 OUT DX AL INC DX OUT DX AL select Logic device 7 DEC DX MOVAL 30H OUT DX AL INC DX MOVAL 01H OUT DX AL Enable GPIO1 DEC DX MOVAL 0F1H O...

Страница 72: ...Bit 1 Bit 0 X X X X X R W R W R W R W Read Write X Not used Bit 2 0 101 Set bypass to disable when power off 110 Set bypass to enable when power off Refer to below program code and set LAN bypass ena...

Страница 73: ...r off MOVDX 02EH MOVAL 07H Logic Device 7 OUT DX AL INC DX OUT DX AL select Logic device 7 DEC DX MOVAL 30H OUT DX AL INC DX MOVAL 01H OUT DX AL Enable GPIO1 DEC DX MOVAL 0F1H OUT DX AL INC DX IN AL D...

Страница 74: ...Windows directory to see their map IRQ Assignment IRQ0 Timer IRQ1 Keyboard IRQ2 Interrupt rerouting from IRQ8 through IRQ15 IRQ3 COM2 IRQ4 COM1 IRQ5 PCI PCI Bridge IRQ6 FDD Controller IRQ7 Ethernet Co...

Страница 75: ...Address Range Type Owner D0000000 DFFFFFFF PCI PCI PCI Bridge FB7FC000 FB7FC3FF PCI USB Controller FB7FE000 FB7FE3FF PCI USB Controller F8000000 FB8FFFFF PCI PCI PCI Bridge FB980000 FB9BFFFF PCI Ethe...

Страница 76: ...00000 00000000 00800000 Reserved 00000000 FEE00000 00000000 00001000 Reserved 00000000 FFA00000 00000000 00600000 Reserved I O Map The addresses shown in the table are typical locations I O Port Assig...

Страница 77: ...therboard Resource 500 57F Motherboard Resource 800 87F Motherboard Resource A00 A0F Motherboard Resource A10 A1F Motherboard Resource CF8 CFF Motherboard Resource 7000 7FFF PCI PCI Bridge 8C00 8C1E E...

Страница 78: ...hernet Cat 5 Cable 2M RoHS CB EC5200 00 1 Cross Over 2M Color RoHS CB CO5204 00 1 RJ45 to DB9 2M Cable RoHS CB RJDB91 00 1 2m null modem cable RoHS CB DB9200 01 1 VGA CABLE 2mm 15CM RoHS CB IVGA01 00...

Отзывы: