WIN Enterprises PL-10510 Скачать руководство пользователя страница 1

 

 

WIN Enterprises, Inc.

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Networking Appliance

 

 

User’s Manual

 

Version 1.3 

 
 

1U Rack-mount Intel® Celeron

™ 

 (codename Bay Trail) Network 

System, Six Copper GbE, CF, SATA, PCIe   and Bypass

 

 
 

 

 
 
 
 

PL-10510

Custom Embedded Solutions

Содержание PL-10510

Страница 1: ...N Enterprises Inc 1 Networking Appliance User s Manual Version 1 3 1U Rack mount Intel Celeron codename Bay Trail Network System Six Copper GbE CF SATA PCIe and Bypass PL 10510 Custom Embedded Solutio...

Страница 2: ...al business Machine Corporation Award is a trademark of Award Software International Inc Intel is a trademark of Intel RTL is a trademark of Realtek VIA is a trademark of VIA Technologies Inc Microsof...

Страница 3: ...Chapter 3 BIOS Setup 21 3 1 Quick Setup 21 3 2 Entering the BIOS Setup Utility 21 3 3 Menu Options 23 3 4 Advanced Menu 23 3 5 Chipset Menu 41 3 6 Security Menu 43 3 7 Boot Menu 44 3 8 Exit Menu 47 Ch...

Страница 4: ...ot with memory up to 8 GB In order to provide the best network performance and utilization the expansive storage interfaces include 2 5 SATA HDD and CompactFlash To enhance the network security perfor...

Страница 5: ...al 3 5 SATA HDD bay CompactFlash Socket one CompactFlash TM Type II I O USB Rear Two external USB2 0 Two internal 5x2 pin header Serial One RJ45 Console port COM1 Expansion PCIe Slot One Standard PCI...

Страница 6: ...e CB DB9200 01 Null modem cable CB IVGA01 01 VGA cable CB IPS200 00 KB MS cable CB IUSB01 00 USB cable 1 4 Packaging Please make sure that the following items have been included in the package before...

Страница 7: ...nts Electrostatic discharge can be easily damage the PL 10510 appliance Do not remove the anti static packing until you are ready to install the PL 10510 appliance Ground yourself before removing any...

Страница 8: ...WIN Enterprises Inc 8 1 6 System Layout PL 10510 Front Side Layout PL 10510 System Layout Layout...

Страница 9: ...WIN Enterprises Inc 9 1 7 Board Dimensions...

Страница 10: ...WIN Enterprises Inc 10 Chapter 2 Connector Jumper Configuration 2 1 Connector Jumper Locations and Definitions...

Страница 11: ...ayout with LED16 CN5 USB Port 2 3 Pin Header CN22 USB Port 0 1 CN6 VGA Pin Header CN23 DC IN Pin Header Co Layout with CN31 CN7 SATA Power Connector CN24 LAN1 CN8 KEY PAD Pin Header CN25 LAN2 CN9 LCM...

Страница 12: ...Defined and Jumper Settings Connector Location Defined CN1 CN2 CN3 System CPU FAN Pin Define 1 Ground 2 12V 3 Speed Detect CN7 SATA PWR 1 2 3 4 Pin Define 1 12V 2 GND 3 GND 4 5V CN8 Keypad header Pin...

Страница 13: ...3 P_AFD 4 NC 5 P_INIT 6 P_SLIN 7 LCM_PD1 8 LCM_PD0 9 LCM_PD3 10 LCM_PD2 11 LCM_PD5 12 LCM_PD4 13 LCM_PD7 14 LCM_PD6 15 LCM_BK_CTRL 16 BK_CTRLP CN10 SPI Pin Header Pin Define Pin Define 1 1 8V 2 GND 3...

Страница 14: ...header Pin Define Pin Define 1 DCD 2 DSR 3 SIN 4 RTS 5 SOUT 6 CTS 7 DTR 8 RI 9 Ground 10 N A CN13 GPIO Pin Define Pin Define 1 3 3V 2 SIO_GP50 3 SIO_GP51 4 SIO_GP52 5 SIO_GP53 6 SIO_GP54 7 SIO_GP55 8...

Страница 15: ...5V 28 GND 26 3 3VAUX 24 PERST 22 RESERVED 20 GND 18 RESERVED 16 RESERVED 14 RESERVED 12 RESERVED 10 RESERVED 8 1 5V 6 GND 4 Pin Define Pin Define 1 WAKE 2 3 3V 3 Reserved 4 GND 5 Reserved 6 1 5V 7 CL...

Страница 16: ...Header Pin Define Pin Define 1 3 3V 2 AD 0 3 AD1 4 AD 2 5 AD 3 6 Frame 7 PCIERST 8 5V 9 CLOCK 10 PME 11 GND 12 13 SERIRQ 14 DRQ CN18 PS2 KB MS Pin Header Pin Define Pin Define 1 KCLK 2 MCLK 3 KDAT 4 M...

Страница 17: ...TA0 3 DATA0 4 GND 5 5V 6 DATA1 7 DATA1 8 GND CN24 29 LAN RJ 45 Connector Pin Define 1 TX 2 TX 3 RX 4 Chassis Ground 5 Chassis Ground 6 RX 7 Chassis Ground 8 Chassis Ground D1 Speed indicated LED 1 Gbp...

Страница 18: ...WIN Enterprises Inc 18 CN30 COM1 Console Connector RJ45 Pin Define 1 CTS 2 DTR 3 TXD 4 GND 5 GND 6 RXD 7 DSR 8 RTS CN31 DC 12V Power Jack 2Pin 1 1 2 2 Pin Define Pin Define 1 12V 2 GND...

Страница 19: ...2 Normal Operation 2 3 Clear CMOS JP2 LAN1 LAN2 bypass select Pin Setting 1 2 By pass mode 2 3 Normal operation JP3 LAN3 LAN4 bypass select Pin Setting 1 2 By pass mode 2 3 Normal operation JP4 Reset...

Страница 20: ...means they contain no moving parts Thus it provides users with much greater protection of the data than conventional magnetic disk device Pin Assignment Pin Assignment Pin Assignment Pin Assignment P...

Страница 21: ...Type of display adapter installed Number and type of disk drives The CMOS memory is maintained by a battery installed on the PL 10510 board By using the battery all memory in CMOS can be retained when...

Страница 22: ...o a different type of CPU Run the AMI Flash program to update the system BIOS Run the BIOS Setup program after you turn on the system On screen instructions explain how to use the program Enter the BI...

Страница 23: ...ns you to the main menu 3 3 Menu Options The main menu options of the BIOS Setup program are described in the following and the following sections of this chapter Main For changing the basic system co...

Страница 24: ...o move between fields Modify the selected field using the PgUP PgDN keys Some fields let you enter numeric values directly 3 After you have finished with the Advanced setup the or key to switch to oth...

Страница 25: ...Mode Watch dog Mode Sec Min Watch dog Timer Set up Watch dog Timer LAN Bypass1 Power off Enabled or Disabled Bypass mode when System Power off LAN Bypass2 Power off Enabled or Disabled Bypass mode wh...

Страница 26: ...WIN Enterprises Inc 26...

Страница 27: ...WIN Enterprises Inc 27 Serial Port 1 2 Configuration Serial Port Enable or Disable Serial Port COM Change Settings Select an optimal setting for Super IO device...

Страница 28: ...WIN Enterprises Inc 28 3 4 3 NCT6791D HW Monitor 3 4 4 Serial port Console Redirection...

Страница 29: ...bytes Bits per second Select serial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds Data Bits Set your Data Bits Parity A parity bit c...

Страница 30: ...nals VT UTF8 Combo Key Support Enable VT UTF8 Combination Key Support for ANSI VT100 terminals Recorder Mode With this mode enabled only text will be sent This is to capture Terminal data Resolution 1...

Страница 31: ...WIN Enterprises Inc 31 Socket 0 CPU Information Active Processor Cores...

Страница 32: ...ned with a supporting OS Windows Server 2003 SP1 Windows XP SP2 SuSE Linux 9 2 RedHat Enterprise 3 Update 3 Intel Virtualization Technology When enabled a VMM can utilize the additional hardware capab...

Страница 33: ...1 or Gen2 SATA ODD Port No ODD mode HDD or SSD ODD mode ODD SATA Mode 1 IDE Mode 2 AHCI Mode 3 RAID Mode Serial ATA port 0 Enabled or Disabled Serial ATA port 0 Serial ATA port 1 Enabled or Disabled S...

Страница 34: ...g Enabled or Disabled 64bit capable Devices to be Decoded in Above 4G Address Space Only if System Supports 64 bit PCI Decoding SR IOV Support Enabled or Disabled SR IOV mode 3 4 8 1 PCI Express Setti...

Страница 35: ...Enabled or Disabled PCI Express Device No Snoop option Maximum Payload Set Maximum Payload of PCI Express Device or allow System BIOS to select the value Maximum Read Request Set Maximum Read Request...

Страница 36: ...ut Use this item to define number of microseconds software will wait before polling Link Training bit in link status register Value range from 10 to 1000uS Unpopulated Links In order to save power sof...

Страница 37: ...s AtomicOp Requests only if Bus Master Enable bit is in the Command Register Set AtomicOp Egress Blocking If supported by hardware and set to Enabled outbound AtomicOp Requests via Egress Ports will b...

Страница 38: ...Compliance SOS If supported by hardware and set to Enabled this will force LTSSM to send SKP Ordered Sets between sequences when sending Compliance Pattern or Modified Compliance Pattern Hardware Auto...

Страница 39: ...g BIOS services ALWAYS do not allow disabling GA20 this option is useful when any RT code is executed above 1MB Option ROM Messages Set display mode for Option ROM Boot option filter This option contr...

Страница 40: ...pport The EHCI ownership change should be claimed by EHCI driver USB Mass Storage Device Configuration Configure the USB Mass Storage Devices USB transfer time out The time out value for Control Bulk...

Страница 41: ...WIN Enterprises Inc 41 the delay is taken from Hub descriptor Mass storage devices Scan your USB port device 3 5 Chipset Menu 3 5 1 Chipset North Bridge...

Страница 42: ...WIN Enterprises Inc 42 3 5 1 1 Chipset North Bridge Intel IGD Configuration GOP Driver...

Страница 43: ...able Enabled or Disabled Integrated Graphics Device Turbo Mode Spread Spectrum clock Enabled or Disabled Spread Spectrum clock 3 5 2 Chipset South Bridge USB 2 0 EHCI Support Enabled or Disabled USB2...

Страница 44: ...Password This item allows you to set or change the administrator password The Administrator Password item on top of the screen shows the default Not Installed After you have set a password this item s...

Страница 45: ...Use the and keys to adjust the number of seconds to wait for setup activation key Bootup NumLock Stat This item allows you to select On or Off power on state for the NumLock Quiet Boot Enabled or Disa...

Страница 46: ...WIN Enterprises Inc 46 Boot Option 1 8 Set the USB boot priority order...

Страница 47: ...llowing screen appears Save Changes and Reset Store all changes you made into CMOS and reboot system F4 key can be used for this operation Discard Changes and Reset Discard all changes you made and re...

Страница 48: ...and Linux operation system as follows Before installation please check your OS version If your OS is not in the following list please upgrade your OS version OS Version DOS DOS 6 22 Windows Windows 7...

Страница 49: ...he LAN driver in the setup CD Please click the Autorun file and install the driver following the procedures 1 Insert the setup CD of PL 10510 into your CD ROM drive 2 Choose the Drivers file to click...

Страница 50: ...ler The value range is from 01H to FFH and the related time watchdog timer interval is 1 sec to 255 sec Data Timer interval 00 Disabled 01 1 sec 02 2 sec FF 255 sec If you want to disable the watchdog...

Страница 51: ...chdog timer After setting the timer interval value the watchdog timer begins to count down You have to refresh the watchdog timer so that the watchdog timer will return to its initial value otherwise...

Страница 52: ...Cat 5 Cable 2M RoHS CB EC5200 01 1 Cross Over 2M Color RoHS CB CO5204 01 1 RJ45 to DB9 2M Cable RoHS CB RJDB91 01 1 VGA CABLE 2mm 15CM RoHS CB IVGA01 00 1 2m null modem cable RoHS CB DB9200 01 1 KB M...

Отзывы: