28 Bath fitting
SanTec OCEAN B7
EN
OCEAN B7
Description of the functions
Stagnation rinse:
DIP switch 6
Serves to remove stagnant water that accumulates in the tub inlet during longer periods
of disuse.
DIP switch 6 ON = Stagnation rinse function enabled.
DIP switch 6 OFF = Stagnation rinse function disabled (default setting).
Time interval
Can be set from 3–48 h at
the interval control
(see p. 19).
Automatic stagnation rinse
If the fitting has not been
used for the set period,
the device automatically
performs a stagnation rinse
operation for 10 s via the tub
inlet.
While stagnation rinse is in
progress, all three fill level
icons light up.
Safety
If the device is in standby
mode or if the cleaning stop
function has been enabled,
the stagnation rinse function
will only start 2 min after
standby mode ends or once
the cleaning stop function
has been disabled.
5 s before and after the
stagnation rinse, the three fill
level icons will flash rapidly.
3–48 h
10 s
Werkseinstellung:
ON
OFF
1 2 3 4 5 6
ON
OFF
1
2
3 4 5
6
ON
OFF
1
2
3 4 5
6
ON
OFF
1 2
3
4 5
6
ON
OFF
1 2 3
4
5
6
ON
OFF
1 2 3 4
5
6
ON
OFF
1 2 3 4 5
6
ON
OFF
1
2
3 4 5
6
ON
OFF
1
2
3 4 5
6
um 07:00 Uhr
um 07:00 Uhr
um 07:00 Uhr