26 Shower control
WimTec PROOF S6
EN
PROOF S6
Assembly
7
7.
Feed the 2 x 0.5 mm
2
power connection cable and into the flush-mount set
and connect it to the power supply (art. no. 117 899 and art. no. 113 792).
Attention: The power supply must not be installed in the flush-mount set!
8.
Connect the magnetic valves to the electronics module.
(red = therm. disinfection)
9.
Connect the power cables to the electronics module.
A
Thermal disinfection:
feed the control line
B
ON/OFF button:
see step 16
C
Infrared sensor: connection
with of the mounting frame
10.
Configure the desired functions at the electronics module and insert the elect-
ronics module into the flush-mounted set.
11.
Connect the power cables to the electronics module (mind c/- polarity)
and connect the grounding wire (yellow) to the water path. Switch on the
power supply (the safety lock mechanism of the magnetic valve will activate).
11
9
8
A
B
C