24 Urinal flush control
WimTec MULTI 2
EN
MULTI 2
ATTENTION!
Perform the following steps
in the order indicated!
!
Assembly - 9-V battery version
7.
Connect magnetic valve with electronics module.
8.
Connect battery module with electronics module
(causing
the safety locking mechanism of the magnetic valve to
activate).
9.
Open the integrated stop valve.
10.
If required, change the electronics module with the desired
settings (see p. 19).
11.
Position the front plate - perform function check. To correctly
position the front plate, ensure the magnetic valve is inserted
at an angle (see p. 23).
12.
Secure from below with a screw.
11
12
10
7
8
9
Содержание MULTI 2
Страница 1: ...Montage und Bedienungsanleitung DE MULTI 2 Assembly and operating instructions EN ...
Страница 26: ......