15
h) Power Supply: +(24...31)V DC, 150mA maximum consumption.
i) Size & Weight (operating): 160mm diameter, 105mm height, 1.9kg.
j) Operating temperature range: -30...+60 degs. Celsius.
k) Protection degree: IP53 (dust and rain).
5-2. Functions
a) Switching capacity: 10 antennas to 1 output.
b) Anti - hot switching self - protected.
c) Ready to transmit output signal.
d) Unused antennas grounding (all antennas when not powered).
5-3. Storage and Shipment
C A U T I O N
Should you need to transport the antenna switch,
use the original packing as described below.
First disconnect antenna cables, afterwards the common coaxial cable and
then the control cable. Remove the ground connection the last. Replace all
11 plastic protective caps. Finally pack the antenna switch in the original
carton. Fill in the empty space if the ACOM2000S automatic antenna selec-
tor will not be transported.
a) Storage environments: the antenna switch must be kept packed in dry
and ventilated unheated premises without chemically active substances (ac-
ids, alkalies etc.) in the following climatic environment:
* temperature range: -40 to +70 degs. Celsius;
* humidity: up to 75% @ +35 degs. Celsius.
b) Shipping Size and Weight W178mm x D194mm x H182mm, 2.5kg (4kg