WilTec VM-P09 Скачать руководство пользователя страница 3

  

© by WilTec Wildanger Technik GmbH  

 

Seite 3  

http://www.wiltec.info

  

 
Kleinteile (je Beutel): 
 

1. 

(4x) M4x12 screw 
(4x) M4x30 screw 
(4x) M4 toothed washer 
 

4. 

(4x) M8x16 screw 
(4x) M84x0 screw 
(4x) M8 toothed washer  

2. 

(4x) M5x12 screw 
(4x) M5x30 screw  
(4x) M5 toothed washer  
 

5. 

(4x) M4/M5 Spacer 
(4x) M6/M8 Spacer 
(4x) M4/M5 Washer  

3. 
 

(4x) M6x12 screw 
(4x) M6x35 screw  
(4x) M6 toothed washer 

6. 

(1x) Bubble Level 
(6x) M86x0 Hex lag bolt 
(6x) Washer 
(6x) Concrete rawl plugl 

 
 

Necessary tools: 
 

 

Crosstip screwdriver 

 

Metal detector for drywall-mounting 

 

Screw wrench 

 

Drill machine with 10 mm masonry drill 

 
Note: 
For the mounting of the wall plate introduce the level in  
the tube and after the installing take it out.  
 
 

Installing on a drywall construction 
For a safe drywall mounting please use two wooden 
beams/rails placed at least at a 30 cm distance from 
each other. 

1.  Use a metal detector to find two adjoining rails and mark 

their position. 

2.  Place the wall plate on the desired place with the help of 

a second person and the level. 

3.  Mark  right  and  left  the  upper,  middle  and  lower  oblong 

holes, that are above the beams or rails. 

4.  All in all 4 or 6 places have to be marked. 
5.  First pre-drill a 3 mm hole in the wall. 
6.  Assisted by a second person, position the wall plate on the wall and  place the oblong holes over 

the drilled holes so that they match. 

7.  In each hole insert a hex lag bolt with washer. 
8.  Tighten the hex lag bolts clockwisely. 
 

Beware:

 Do not fasten the bolts too tightly in order to avoid causing damage to the wall. 

Beware:

 Do not let go of the wall plate, before it is properly fixed. 

 

Installation on a concrete wall 
Attention: concrete rawl wall plugs or special rawl plugs must be used from the local ironware 
trades. 

1.  First place the wall plate on the wall with the help of the bubble level.  
2.  Mark right and left the upper, middle and lower oblong holes. 
3.  First drill bores with a 10 mm 

– masonry drill. 

4.  Insert in every hole a concrete rawl plug and if necessary hammer it carefully in the borehole.  
5.  When  the  rawl  plugs  are  inserted,  place  the  wall  plate  over  them  so  that  the  position  of  the 

rawl plugs coincides with that of the oblong holes. 

6.  Screw  the  hex  lag  bolts  in  the  rawl  plugs,  tighten  them  lightly  and  screw  tightly  only  after  all 

hex lag bolts have been already inserted. 

 
 
 
 

Отзывы: