© by WilTec Wildanger Technik GmbH
Seite 13
http://www.wiltec.info
WARNING:
Read all safety warnings and instructions. Any failure due to disrespect of the safety instructions may
result in electric shock, fire and / or serious injury.
Keep all warnings and instructions for the future.
Resistance
During continuous operation, the maximum temperature of the liquid to deliver should not exceed
+35°C.
The delivery of aggressive liquids (such as acids, alkalis, silo seepage, etc.) as well as liquids contain-
ing abrasive materials (sand etc.) is to be avoided.
Electrical connection
The electrical connection is made to a grounded socket 230 V ~ 50 Hz. Hedging at least 6 amps.
By an integrated thermal motor protection, the engine is protected from overload and blockage.
Mains connection
The acquired pond pump is already equipped with a grounded socket. The pump is intended for a
connection to a grounded socket with 230 V ~ 50 Hz. Make sure that the socket is adequately secured
and in a good condition. Run the pump plug into the socket. The pump is ready for operation.
Note:
Installation
8. Check out whether the mains voltage corresponds with the specifications on the nameplate.
9. Do not place the pump directly in the pond mud but on a stone in order to make sure that no mud
is drawn in.
10. Check the delivery head (maximum depth). This information can be likewise found the nameplate.
11. The pump is installed as follows: either in a fixed position with a fixed tubing or in a fixed position
with flexible tubing.
12. Route the cord in a protected way in order to avoid the possibility of damage.
13. Connect the pump to the power supply.
14. As long as being connected to the power supply the pump keeps its operation.
Commissioning
Having read the afore-mentioned instructions carefully, you may operate the pump under the following
conditions:
Check out whether the pressure line is attached properly.
Make sure that the electrical connection is 230V~50Hz.
Make sure that the socket is in a proper condition.
Make sure that there is never any contact between humidity or water with the mains connection.
Install the pump below the water surface.
Make sure that the pump never runs dry.
Never operate the pump without a filter basket. The filter basket protects the pump from coarse
dirt that may lead the pump to get clogged.
Never install the pump in the pond mud.