WilTec CTF-2800 Скачать руководство пользователя страница 4

  

© by WilTec Wildanger Technik GmbH  

 

Seite 13  

http://www.wiltec.info  

 

 
WARNING: 
 

Read all safety warnings and instructions. Any failure due to disrespect of the safety instructions may 
result in electric shock, fire and / or serious injury.  
Keep all warnings and instructions for the future.  
 
Resistance 
During  continuous  operation,  the  maximum  temperature  of  the  liquid  to  deliver  should  not  exceed 
+35°C. 
The delivery of aggressive liquids (such as acids, alkalis, silo seepage, etc.) as well as liquids contain-
ing abrasive materials (sand etc.) is to be avoided. 
 
Electrical connection 

 

The electrical connection is made to a grounded socket 230 V ~ 50 Hz. Hedging at least 6 amps.  

 

By an integrated thermal motor protection, the engine is protected from overload and blockage.  

 
Mains connection  
The  acquired  pond  pump  is  already  equipped  with  a  grounded  socket.  The  pump  is  intended  for  a 
connection to a grounded socket with 230 V ~ 50 Hz. Make sure that the socket is adequately secured 
and in a good condition. Run the pump plug into the socket. The pump is ready for operation. 
 

 
Note: 

 

Installation 

 
8.  Check out whether the mains voltage corresponds with the specifications on the nameplate. 
9.  Do not place the pump directly in the pond mud but on a stone in order to make sure that no mud 

is drawn in. 

10.  Check the delivery head (maximum depth). This information can be likewise found the nameplate. 
11.  The pump is installed as follows: either in a fixed position with a fixed tubing or in a fixed position 

with flexible tubing. 

12.  Route the cord in a protected way in order to avoid the possibility of damage. 
13.  Connect the pump to the power supply. 
14.  As long as being connected to the power supply the pump keeps its operation.  
 

Commissioning 
 

Having read the afore-mentioned instructions carefully, you may operate the pump under the following 
conditions: 
 

 

Check out whether the pressure line is attached properly. 

 

Make sure that the electrical connection is 230V~50Hz. 

 

Make sure that the socket is in a proper condition. 

 

Make sure that there is never any contact between humidity or water with the mains connection. 

 

Install the pump below the water surface. 

 

Make sure that the pump never runs dry. 

 

Never  operate  the  pump  without  a  filter  basket.  The  filter  basket  protects  the  pump  from  coarse 
dirt that may lead the pump to get clogged. 

 

Never install the pump in the pond mud. 

Содержание CTF-2800

Страница 1: ... the version Vor Inbetriebnahme Bedienungsanleitung und Sicherheitshinweise lesen und beachten Read and follow the operating instructions and safety information before using for the first time Avant la mise en service lisez le mode d emploi et les consignes de sécurité et respectez les Subject to technical changes Due to further developments illustrations functioning steps and technical data may d...

Страница 2: ...minimize the risk of injury by fire or electric shock we kindly ask you to take same basic safety precautions into account when using this device Please read these operating instructions thoroughly and make sure that you have understood them Always use a grounded power supply with the correct voltage The corresponding mains voltage is indicated on the nameplate In case you are unsure whether the c...

Страница 3: ...ponsible for the safety in the work area If the power cord or the plug is damaged by external influences the cord must not be re paired The cord must be replaced with a new one This operation must be carried out only by a qualified electrician The Voltage of 230 AC volts as indicated on the device s nameplate has to be according to the mains voltage Never lift transport or fix the device by using ...

Страница 4: ... 8 Check out whether the mains voltage corresponds with the specifications on the nameplate 9 Do not place the pump directly in the pond mud but on a stone in order to make sure that no mud is drawn in 10 Check the delivery head maximum depth This information can be likewise found the nameplate 11 The pump is installed as follows either in a fixed position with a fixed tubing or in a fixed positio...

Страница 5: ...F 5000 30W 5000 l h 3 3 m 1 1 1 10 m CTF 6000 40W 6000 l h 4 2 m 1 1 1 10 m CTF 7000 50W 7000 l h 4 6 m 1 1 1 2 10 m CTF 8000 70W 8000 l h 5 6 m 1 1 1 2 10 m CTF 10000 80W 10000 l h 6 m 1 1 1 2 10 m CTF 12000 100W 12000 l h 6 5 m 1 1 1 2 10 m CTF 14000 120W 14000 l h 7 m 1 1 1 2 10 m CTF 16000 140W 16000 l h 7 5 m 1 1 1 2 10 m Maintenance The pond motor pump is a proven quality product subjected t...

Страница 6: ...fo 1 Blue cover on top 2 Upper pump housing 3 Holder 4 Holder 5 Engine 6 Pump holder 7 Lower pump housing 8 O ring 1 9 Bearing cover 10 Bearing 11 Rotor 12 Rotor cover 13 O ring 2 14 Flange 15 Screw 16 O ring 3 17 Outlet 18 O ring 4 19 Flange 2 20 Blue cover side ...

Страница 7: ...GmbH Seite 16 http www wiltec info 1 Upper pump housing 2 Holder 3 Holder 4 Engine 5 O ring 1 6 Pump holder 7 Lower pump housing 8 Bearing cover 9 Bearing 10 Rotor 11 Rotor cover 12 O ring 2 13 Flange 14 Outlet 15 O ring 3 16 Screw ...

Страница 8: ...for these devices The symbol on the product or on its packaging indi cates that this product must not be treated as normal domestic waste but must be handed over to a collec tion point for the recycling of electric and electronic devices By contributing to a correct disposal of this product you protect your environment and the health of others Environment and health are affected by inappropriate d...