Cable connections

 

 

Mains connection

 

 

 

The device is equipped with a 3.3

 

m supply cable and plug. Connect the supply cable to the 

mains.

 

 

Note: 

The fuse required is 16

 

A.

 

 

When using an extension cord, the cross-sectional area of this should to at least be as large as 
the one of the supply cable (3×2,5

 

mm²). The maximum length of the extension cord is 50

 

m.

 

 

The welder can also be operated via a current generator. The minimum power of the generator 
is 3.5

 

kVA, the recommended one is 6.0

 

kVA, so that the device can be used at full capacity.

 

 

Earthing

 

 

The earth cable is already connected to the machine. Clean the surface of the workpiece and attach the 
earthing clamp to the piece to establish a closed and failure-free circuit required for welding.

 

 

Welding gun

 

 

 

The welding gun is already connected to the machine. The welding gun leads the shielding gas, 
welding wire, and electric current to the weldseam. When pressing the trigger of the welding 
gun, the shielding gas begins to flow and the wire to be fed. The arc ignites when the welding 
wire touches the workpiece.

 

 

The neck of the welding gun can be rotated by 360°. When rotating the neck, make sure that 
the neck is rotated almost to the stop. Thus, you will prevent damages and overhitting of the 
neck.

 

 
 

Note: 

When using a welding wire with a diameter other than 0.8

 

mm, adapt the contact tip of the welding 

gun according to the thickness of the wire.

 

 
 

Shielding gas

 

 

 

The shielding gas required for steel wires is carbon dioxide or a mixture of argon and carbon 
dioxide that replaces the air near the arc. The thickness of the welding sheet and the welding 
power define the gas flow.

 

 

The device comes with a 4.5

 

m shielding gas hose. Connect the bayonet coupling of the shield-

ing gas hose to the hose connection of the device and the nozzle to the regulation valve of the 
gas bottle.

 

 

 

Содержание 62551

Страница 1: ...ary depending on model Please read and follow the operating instructions and safety information prior to initial operation Technical changes reserved Illustrations functional steps and technical data...

Страница 2: ...https www wiltec de contacts The most recent version of this manual in several languages can be found in our online shop https www wiltec de docsearch Our postal address is WilTec Wildanger Technik G...

Страница 3: ...l welding machine but also on the work piece and work environment Therefore all instructions of this user s manual must be followed During welding electric current is led to the welding wire and workp...

Страница 4: ...ng machine or another electric device Welding fumes Make sure that there is enough aeration Take special precautions when welding metals that contain lead cadmium zinc quicksilver or beryllium Suffici...

Страница 5: ...n The welding gun is already connected to the machine The welding gun leads the shielding gas welding wire and electric current to the weldseam When pressing the trigger of the welding gun the shieldi...

Страница 6: ...main switch 5 Turn half way the fixing screw of the feed roll with a 2 0 mm socket head wrench 6 Remove the feed roll from its shaft 7 Turn the feed roll and replace it on the shaft all the way down...

Страница 7: ...o run unevenly Reversing polarity Certain solid wires are more suitable for being welded with the gun being attached to the negative pole in that case polarity should be reversed Check the recommended...

Страница 8: ...supply voltage too low or too high the welding process is automatically interrupted the yellow overhitting diode is lit It goes out as soon as the device is again ready for use Make sure that there is...

Страница 9: ...djusted in case the thickness of the sheets welded changes Maintaining and cleaning When maintaining the device consider the utilisation ration and environmental conditions If used properly and mainta...

Страница 10: ...m the terminal of the device b Disconnect the plug of the discharge lines of the device c Open the fixing nut of the gun d Carefully remove the gun from the device as soon as all parts emerge through...

Страница 11: ...s not narrowed of worn out The control diode of the main switch is not lit The device has no supply voltage Check fuses of supply voltage Check cable and plug of supply voltage Bad welding perfor manc...

Страница 12: ...ntries of the European Union and other European countries with a separate waste collection system for these devices The symbol on the packaging or the product itself indi cates that this product must...

Отзывы: