Technical data

Intake voltage

 (V)

230

Frequency

 (Hz)

50

Compressor power

 (W)

1100 (1.5 hp)

Max. rotation speed 

(rpm)

2850

Suction capacity

 (ℓ/min)

206

Tank capacity 

(ℓ)

50

Noise level

 (dB (A))

83

Max. operating pressure 

(bar)

8

Test pressure 

(bar)

12.6

Temperature range

 (

)

5–150

Weight

 (kg)

30

Connections

NW7.2

Equipement

Thermal motor protection

2 compressed air connections

2 pressure gauges

1 pressure reducer

Oil lubricated

Pressure relief valve

Before commissioning

Place the compressor in a clean, dry and well-ventilated place.

Use only 230 V operating voltage with a maximum fluctuation of 5 %.

At the oil level, check whether it is within the red display circuit.

Use SAE30 gear oil when the ambient temperature is above 10 

. If the ambient temperature

is below 10 

, use SAE10 gear oil.

Open the drain valve, adjust the pressure and let the compressor run for 10 min without any
equipment connected so that all moving parts lubricate themselves.

Settings

The compressor is secured by a pressure switch. As soon as the max. boiler pressure is
reached, it switches off automatically. As soon as the pressure has fallen below the minimum
rate,   it   switches   on   again.   This   pressure   setting   was   made   ex   factory   and   must   not   be
changed. As soon as the engine switches off, the compressed air in the discharge pipe should
be released by the release valve under the switch. This works automatically and is necessary
to avoid damaging the engine. The pressure can be varied by turning the screw bolt.

The discharge pressure can be adjusted by the pressure regulator.

When you turn off the compressor, turn it off with the on/off switch.

Specific safety instructions

First remove the gear oil cover and insert the red plug.

Never unscrew a connection when the tank is under pressure.

Never disconnect an electrical connection when voltage is applied to the mains plug.

Never change the settings of the safety relief valve.

Make sure that the mains voltage does not deviate from 230 V by more than 5 %.

© by WilTec Wildanger Technik GmbH 

Item 61958

Page 7

http://www.WilTec.de
http://www.aoyue.eu  

  

02 2021

-1

http://www.teichtip.de

Содержание 61958

Страница 1: ...g instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignific antly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Страница 2: ...anguages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pick up address is WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschweiler Germany To shorten the waiting time and allow for a rapid on site transaction we ask you to call us previously or pla...

Страница 3: ...d tilt the compressor to drain the accumulated water To avoid danger the compressed air jet must never be directed at persons or animals To avoid combustion never touch the pipes engine or any other hot components of the com pressor Do not make any changes to the compressor Contact the manufacturer or an authorized ser vice partner for all repairs Unauthorized modifications may affect compressor p...

Страница 4: ...out any repair inspection maintenance cleaning or component replacement work the compressor must be disconnected from the mains supply and the pressure released from the boiler Never use the compressor near water or in a humid environment Always wear protective glasses or eye protection Never point the compressed air jet at your own body or at other persons Never operate the compressor unless all ...

Страница 5: ...his can lead to a reduced service life of the compressed air hose Ensure that the intake air is clean dry and dust free Do not place the compressor in a wet or humid room Description This compressor impresses with its new design and excellent operation It has a very compact con struction good appearance low weight easy handling good safety and low noise level It can be used for machines air brushe...

Страница 6: ...4 Pressure regulator A Discharge pressure 5 Pressure gauge B Tank pressure 6 Check valve C Safety valve 7 Drain cock D Discharge valve 2 8 Wheel E Discharge valve 1 9 Discharge tube F Pressure regulator by WilTec Wildanger Technik GmbH Item 61958 Page 6 http www WilTec de http www aoyue eu 02 2021 1 http www teichtip de ...

Страница 7: ...compressor is secured by a pressure switch As soon as the max boiler pressure is reached it switches off automatically As soon as the pressure has fallen below the minimum rate it switches on again This pressure setting was made ex factory and must not be changed As soon as the engine switches off the compressed air in the discharge pipe should be released by the release valve under the switch Thi...

Страница 8: ...ssor with water jets or flammable liquids Do not place any flammable objects near the compressor Set the push button and power button to OFF when pauses are made or the unit is not in use Never aim the air jet at people or animals Never transport the compressor as long as there is pressure in the tank Make sure that some parts of the compressor head pressure hoses can become very hot Do not touch ...

Страница 9: ...get into the compressor Check and remove Piston hits the valve Replace cylinder gasket Moving parts worn out Replace cylinder gasket Pressure too low or unloading capacity low Motor runs too slowly Check and repair Air filter dirty Clean or replace Safety valve leaking Check or change Drain valve leaking Check or repair Gasket damaged Check and change Valve blocked Remove and clean Worn piston rin...

Страница 10: ...Exploded view by WilTec Wildanger Technik GmbH Item 61958 Page 10 http www WilTec de http www aoyue eu 02 2021 1 http www teichtip de ...

Страница 11: ...48 Washer 8 mm 2 17 Oil cover 1 49 Washer 10 mm 2 18 Oil level indicator seal 1 50 Sleeve 10 mm 2 19 Oil level indicator 1 51 Wheel 2 20 Screw M6 10 1 52 Bolt screw 10 mm 2 21 O clip 5 6 1 8 1 53 Pedestal 1 22 Rubber gasket 1 54 Drain valve 1 23 Piston rod 1 55 Tank 1 24 Allen screw M8 22 left 1 56 Screwing Rp 2 25 Crankshaft 1 57 Nut Rp 1 26 Crankcase 1 58 Pressure regulator 1 27 Protective ring ...

Страница 12: ...nts out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment By contributing to the correct disposal of this art icle you protect the environment and the health of your fellow men Environment and health are threatened by inappropriate disposal Materials recycling helps reduce the consum...

Отзывы: