Operation Manual 

 

Egg Incubator 

52170 

 
 
 

 

 
 
 
 
 

 

Similar to image, may vary depending on model

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Read and follow the operating instructions and safety information before use. 
 
 
Technical changes reserved! 
Due to further developments, illustrations, functioning steps and technical data can differ slightly. 

 

Содержание 52170

Страница 1: ...lar to image may vary depending on model Read and follow the operating instructions and safety information before use Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ slightly ...

Страница 2: ...ice wiltec info or use our contact form https www wiltec de contacts The most recent version of this manual in various languages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pick up address is WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschweil...

Страница 3: ...reduce the risk of accidents If the electricity cable or the electricity plug are damaged due to external influences the cable must not be repaired but needs to be exchanged This work must only be carried out by a qualified technician The rated voltage on the type label of 230 V AC needs to correspond to the existing mains voltage The device must never be lifted transported or attached from its el...

Страница 4: ...cubator run for a week without eggs This way it is easy to see if all parameters can be adjusted and working as required Additionally you will learn how the functions and the adjustments of the in cubator work during this time Nothing is more harmful to the eggs than the wrong adjustments of the incubator If everything worked accordingly in the testing period the incubator can be cleaned thor ough...

Страница 5: ... it needs to be increased How to check the thermometer Keep notes regarding the time of the brood as these are a reliant aid You will soon have the required routine to select the right adjustments and settings for a success ful hatch Alternatively an additional thermometer can be placed in the incubator to be able to perceive the vari ous temperature differences and readjusting the temperatures of...

Страница 6: ...ong er Your incubator is equipped with a fully automatic turning system The automatic turning system of the appliance turns the eggs slowly and consistently Therefore the eggs can be turned from day one The system is so slow that the embryos are not exposed to shocks This is because they are very sensitive and sudden movements should be avoided especially in the first few days If possible the incu...

Страница 7: ...on as the egg membrane can dry and get stuck to the chick before it is able to get out of the egg Thus the chick cannot turn any longer and hatch out of the egg Note There has to be a sufficient fresh air flow as the young animals can otherwise suffocate in the closed container If an integrated air hole is available it will ensure for fresh air Operation 1 The package contains an incubator for 24 ...

Страница 8: ...sed egg is covered with a powder like substance which must not be wiped off or stored in the fridge 2 The surface of the eggshell needs to be free of any deformation tears or marks 3 There is no necessity to disinfect the fertilised eggs as an improper disinfection can negatively im pact the hatching rate Just ensure that the eggshell is clean and without marks 4 When placing the egg into the incu...

Страница 9: ...the egg from the side A well developed em bryo is bigger and should fill the egg out nearly entirely letting hardly any light through If the embryo is dead the blood vessels in the egg blurred parts near the air cell are discoloured yellow and the sections between the egg and the air cell is not clearly defined 8 Increase the air humidity during the breeding time and decrease the temperature This ...

Страница 10: ... to the electricity source 3 Switch the electricity source on 4 Switch the incubator on 5 An alarm will sound due to low temperature humidity This is normal 6 Press a random button to turn the alarm off 7 Let the incubator run and fill the water channels You will notice that the humidity will increase 8 Push the reset button to check the automatic turning mechanism This will begin every two hours ...

Страница 11: ...recommended to fill the water channels up every 4 5 days On day 18 when the egg inserts are removed they should be overfilled to raise the humidity to approx 65 Make sure that neither the eggs nor the equipment are allowed to get wet Calibration of the temperature measurement CS The correct measured value of the thermometer is set to 0 The displayed value of the thermometer can be adjusted if you ...

Страница 12: ... water into one or both water channels depending on the local air humidity 4 Lay the eggs with the tips of the egg pointing downward 5 Close the lid and switch the incubator on 6 Push the reset button left green button to reset the day count to 0 and to start it this will al so reset the egg turning countdown to 1 59 h 7 Pay attention to the humidity measurements and refill water when required usu...

Страница 13: ...f 75 80 Turn the eggs at least once a day around their longitudinal axis 2 Blood dots which point to an early death of the embryo a Temperature of the incubator is too high or too low a Check the thermometers thermostat and the electricity follow the instructions of the manufacturer b See 1 g b See 1 g 3 Broken egg shells a See 2 a a See 2 a b Eggs were not turned properly b Turn the eggs frequent...

Страница 14: ...average size Small chicks c Too low humidity in the incubator c See 4 Heavily breathing chicks d Too high humidity in the incubator d See 4 e Possibly infectious disease e Bring the chicks to a vet for diagnosis f Lower the temperature during the time in the incubator f See 2 a Weak chicks g Ventilation of the incubators is too low g See 3 d h Omphalitis navel infection h Clean and disinfect the i...

Страница 15: ...tries with a separate collection system for these appliances The logo on the item or on its packaging points out that this item must not be treated as normal household waste but must be disposed of at a recycling collection point for electronic and electrical waste equipment By contributing to the correct disposal of this item you help protect the environment and the health of fellow human beings ...