WilTec 52016 Скачать руководство пользователя страница 6

 

© by WilTec Wildanger Technik GmbH  

Item 52016 

Page 6 

 

http://www.WilTec.de

 

http://www.aoyue.eu   

   

10 2021

-1

 

http://www.teichtip.de

 

 

Basic functions

 

 

1.  Press 

“SET” 

(5)

 and 

“+” 

(6)

 while the incubator is not supplied with energy to restore the factory 

settings (turning interval: every 2 h during 10 s). 

2.  Press the LED switch 

(2)

 during 3 s to test the egg turning function. By pressing the up and 

down buttons 

(6, 7),

 the turning interval can be adjusted. 

 
 

Temperature adjustment

 

 
The factory temperature setting is 38 

 (100 °F). The temperature can be adapted to different types of 

clutches  and  ambient  temperature.  Should  the  incubator  not  have  reached  38 

  (100 °F)  even  after 

several hours of operation, check the following: 
 

1.  Has the temperature been set to 38 

 (100 °F)? 

2.  Does the fan work properly? 
3.  Is the lid closed? 
4.  Is the ambient temperature above 18 

 (64.4 °F)? 

 
To check and modify the temperature settings, proceed as follows: 
 

1.  Press the 

“SET” button 

(5)

 once.

 

2.  Press 

“+” 

(6)

 or 

“–” 

(7)

 to adjust the desired temperature. 

3.  Press 

“SET” 

(5)

 to complete the adjustment. 

 

Adjustments of temperature alarm value (AL and AH) 

 
The alarm value is set to 1 

 (33.8 °F) in the factory. 

 

Adjustment of alarm when temperature is too low (AL) 

 

1.  Press the 

“SET” button 

(5)

 during 3 s. 

2.  Press the 

“SET” button 

(5)

 repeatedly until 

“AL” is displayed. 

3.  Press 

“+” 

(6)

 or 

“–” 

(7)

 to define the desired temperature alarm value. 

 

Adjustment of alarm when temperature is too high (AH) 

 

1.  Press the 

“SET” button 

(5)

 during 3 s. 

2.  Press the 

“SET” button 

(5)

 repeatedly until 

“AH” is displayed. 

3.  Press 

“+” 

(6)

 or 

“–” 

(7)

 to define the desired temperature alarm value. 

 

Adjustment of upper and lower temperature limit (HS and LS) 

 
With the upper limit set to for example 38.2 

 (100.8 °F) and the lower limit to 37.4 

 (99.3 °F), the 

temperature of the incubator can only be adjusted to a value comprised between these two limits. 
 
 

Calibrating the temperature sensor 

 
The  thermometer  is  set  to  0 

  (32 °F)  in  the  factory.  In  case  the  temperature  display  has  deviating 

values, you can adjust the temperature sensor. Use a standardised external thermometer to determine 
the correct temperature values. The deviation between the temperature display and the external ther-
mometer is the value to be set.

 

 

1.  Press the 

“SET” button 

(5)

 during 3 s. 

2.  Press the 

“SET” button 

(5)

 repeatedly until 

“CAU” is displayed. 

3.  Press 

“+” 

(6)

 or 

“–” 

(7)

 to define the desired value.

 

Содержание 52016

Страница 1: ...y vary depending on model Please read and follow the operating instructions and safety information prior to initial operation Technical changes reserved Illustrations functional steps and technical data may deviate insignificantly due to continuous further developments ...

Страница 2: ...https www wiltec de contacts The most recent version of this manual in several languages can be found in our online shop https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany Do you wish to collect your goods Our address for collection is WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschweiler Germany In order to shorten t...

Страница 3: ... long term test 1 Make sure that the rotary shaft is properly fixed to the egg rack 2 Plug in the power cord 3 The incubator emits an alarm tone after plugging in for the temperature inside the device is too low 4 Stop the alarm by pressing any button 5 Fill the water reservoir to gradually increase the air humidity It is recommended to use warm water 6 The turning interval is pre set to 2 h Obser...

Страница 4: ...mpera ture is below 20 6 Fill in water pre heat the incubator After 20 30 min check values You can now start incuba tion 7 The eggs need a distance of 2 3 mm to the spacers Check of air humidity during incubation The following example refers to a hen s egg Schedule the incubation process by defining three different phases that require different humidity values Figure 1 Phase 1 Day 1 to 7 Only the ...

Страница 5: ...3 Phase 3 Day 15 to 21 Fill all parts of the water reservoir Fig 3 Attention Different clutches require different air humidity values The data mentioned above corre spond to hen s eggs When incubating eggs of other specied adapt the air humidity to the individual clutch Adjustments Name Name 1 LED lamp 5 Adjustments 2 Switch to 1 6 Up 3 Temperature display 7 Down 4 Status LED of heater 8 Status LE...

Страница 6: ...e alarm value AL and AH The alarm value is set to 1 33 8 F in the factory Adjustment of alarm when temperature is too low AL 1 Press the SET button 5 during 3 s 2 Press the SET button 5 repeatedly until AL is displayed 3 Press 6 or 7 to define the desired temperature alarm value Adjustment of alarm when temperature is too high AH 1 Press the SET button 5 during 3 s 2 Press the SET button 5 repeate...

Страница 7: ... the intrusion of bacteria through the eggshell Troubleshooting chart problems with the chicks Problem Possible cause Solutions 1 Too much egg white or too many un fertilised eggs a Wrong ratio of male and female ani mals a Check mating conditions according to breeder s recommendations b Male animal malnourished b Feed roosters separately so that chickens do not take most of the food c Interruptio...

Страница 8: ... Temperature inside incubator proba bly too high 6 Deformed chicks a Too high a temperature inside incuba tor a See 2 a b Too low a temperature inside incuba tor a See 2 a c Eggs turned improperly c See 3 b ensure to insert eggs with wider part first 7 Chicks with straddled legs Breeding inlay too slippery smooth Use wire inlay or cover slippery smooth ground with e g sackcloth 8 Weak chicks a Inc...

Страница 9: ...Store the eggs at a cool temperature 8 15 and at a relative air humidity of 75 If the hatching eggs have been sent you via post they should rest for at least 24 h before being placed in the incubator Important The eggs should be stored lying and need to be rotated halfway around their longitudinal axis at least once a day 2 When is the incubator ready The incubator should run for at least 24 hours...

Страница 10: ...37 4 37 6 Pigeon 38 5 Goose 37 6 Quail 37 6 37 8 Note A short temperature drop while checking the eggs usually is not a problem for the embryos Con trariwise temperatures exceeding the recommended one are harmful and even deadly and should be avoided at all costs 4 Does my thermometer show exact values Thermometers are not exact Keeping the temperature constant might be difficult even with good th...

Страница 11: ...id these problems change the water surface in the incubator To increase the humidity and thus to enlarge the water surface place an additional container with wa ter a few small moist sponges in the incubator Alternatively the eggs can be sprayed with fine water mist To reduce the humidity decrease the water surface by using smaller containers 6 How long is the incubation time Type of poultry Incub...

Страница 12: ...ide a starting aid by carefully opening the eggshell a little bit Certainly a sure instinct is needed as well in this condition for you must not help them too early Oftentimes a wrong humidity can be the reason for that as the egg membrane can dry and get stuck to the chick before it is able to get out Thus the chick cannot turn any longer and hatch Note There has to be a sufficient fresh air flow...

Страница 13: ...has still grown filling nearly the entire egg so that most of the light is absorbed In case the embryo is dead the inside blood vessels are indistinct parts near the air chamber have adopted a yellowish colour and the line between the egg and air chamber is not clearly visible 3rd day 6th day 8th day 10th day 15th day 19th day 8 During incubation increase the air humidity and lower the temperature...

Страница 14: ...untries of the European Union and other European countries with a separate waste collection system for these devices The symbol on the packaging or the product itself indi cates that this product must not be treated as normal domestic waste but must be disposed of at a recycling collection station for electrical and electronic waste By disposing of this product correctly you contribute to the prot...