Safety Instructions

 

 

This  device  can  only  be  used  in  the  vicinity  of  bodies  of  standing  water,  garden  ponds  or  swimming 
ponds,  if  connected  to  a  fault  current  protection-switch  with  a  triggering  nominal  current  up  to  30mA 
(according to VDE 0100 Article 702 and 738).

 

 
The device is not suitable for usage in swimming pools, paddling pools and other bodies of water, which 
might be used by people or animals during operation. The device must not be used while sentient beings 
are within the hazard area. In case of doubt contact a professional electrician. 

 

 
This  device  can  only  be  utilized  by  children  or  individuals  with  reduced  physical,  sensory  or  mental 
capabilities, or lack of experience and knowledge, if they have received instructions concerning the use 
of the appliance from and are being supervised by a person familiar with the product and responsible 
for their safety. Children should be supervised at all times in order to ensure that they do not play with 
it.

 

 
 

 

Run a visual inspection of the device before every use. Do not use the device, if safety appli-
ances are damaged or show signs of wear. Never ignore safety regulations. 

 

 

Only use the device for its intended purpose stated in this instruction manual.

 

 

You are responsible for the safety within your working environment. 

 

 

The cable or plug must not be repaired in case of being visibly damaged and instead has to be 
replaced with a new one by a qualified electrician. 

 

 

The voltage indicated on the type plate of the device corresponds to 230 Volt alternating voltage 
and has to match the mains voltage on site.

 

 

Never pull, lift, carry or fixate the device by its power cable. 

 

 

Always ensure that the power plug and socket-outlet are located within a flood-proof area and 
are protected from moisture

 

 

Always disconnect the device from the mains supply before performing repairs or maintenance 
work. 

 

 

Ensure that the device is not directly hit by streams of water. 

 

 

The owner of the device  is responsible for its proper installation  in  accordance  with the local 
installation and safety regulations. (Eventually contact a qualified electrician)

 

 

The user is responsible for taking the appropriate measures (such as the installation of alarm 
systems  or  standby  pumps)  in  order  to  avoid  consequential  damage  caused  by  flooding  of 
rooms due to a malfunction of the device. 

 

 

The pump must never run dry or be utilized while its inlet port is closed completely. In case of 
the device running dry, the manufacturer warranty will be voided.

 

 

The device must not be connected to systems supplying drinking water. 

 

 

The device must not be utilized to operate swimming pools.

 

 
 

Carefully read all the safety guidelines and instructions found in this manual

.

 

Failure to comply with the rules safety rules and regulations may lead to electric shock, fire and/or seri-
ous damage and injuries. Always make sure to properly store this instruction manual for future reference.

 

 

Stability

 

The maximum temperature of the conveyed liquid should not 35°C during permanent opera-
tion. The conveyance of flammable, gassing or explosive liquids is forbidden while the conveyance of 
aggressive fluids (such as acids and bases) as well as abrasive liquids (such as sand) must be avoided 
in order to prevent the pump from being damaged.

 

 
In order to prevent the pump from running dry, we recommend the use of one of our automatic pump 
control systems.

 

 

Содержание 51548

Страница 1: ...rating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignif...

Страница 2: ...ors cannot always be avoided In the event of problems with this user manual please complete and send this form back to us FAX notification 49 2403 55592 15 from _______________________________________...

Страница 3: ...voltage and has to match the mains voltage on site Never pull lift carry or fixate the device by its power cable Always ensure that the power plug and socket outlet are located within a flood proof ar...

Страница 4: ...th a pre filter Pumping media Only fresh water rain water or mild suds may be pumped with this device Operation instructions We generally recommend the use of a pre filter as well as a suction set con...

Страница 5: ...1 Cable 2 Motor cover 3 Handle 4 Pump head 5 Valve cover Electrical connection The electrical connection takes place via an isolated ground receptacle with 230 V 50 Hz fuse protection and at least 10...

Страница 6: ...ess a diameter of 3 4 has to either be connected directly to the pressure line connector 1 internal thread of the pump or via a threaded nipple A smaller pressure line with a diameter of 1 2 can be at...

Страница 7: ...ds In most cases this should suffice in order remove clogging Troubleshooting The motor does not start Causes Solutions Line voltage is missing Check the power supply Pump impeller jams Thermal contro...

Страница 8: ...European countries with a separate col lection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste but...

Отзывы: