WilTec 50600 Скачать руководство пользователя страница 6

Changing the Membrane

1. Turn off the electricity and water supply. If necessary, release the water from the piping sys-

tem.

2. Disconnect the vessel from the piping system and expel the air via the pre-charge valve.
3. Loosen the counter-flange screws and remove the flange.
4. Exchange the rubber membrane. 
5. Mount the counter-flange back into place and tighten the screws again.
6. The pre-charge needs to be installed again.
7. Check the counter-flange area for leaks. 
8. Connect the vessel back to the piping system.
9. Repeat the previously stated installation steps.

Maintenance and care instructions

The pressure vessel should be checked annually by a specialist who is able to carry out main-
tenance work.

Before any maintenance work is carried out, the vessel needs to be taken out of operation,
thus remove the vessel from the electricity and let it cool down.

Ensure that the pre-charge pressure matches the one stated on the type label. The max. toler -
ance of the pressure is ±20 %.

The pre-charge pressure should be lower than the start-up pressure of the pressure switch
and 0.1–0.2 bar below the start-up pressure of the pump.

Never demount the vessel if it is not entirely empty and without pressure.

Check the pre-charge and working pressure several times a year. 

Before buying a replacement EPDM rubber membrane, the diameter of the opening needs to
be determined. The membrane diameter is the same as the vessel opening. You can find suit-
able membranes and other wearing parts at www.wiltec.de.

Important notice:

The reprint or reproduction, even of excerpts, and any commercial use, even in part of this instructions
manual require the written permission of WilTec Wildanger Technik GmbH.

© by WilTec Wildanger Technik GmbH Item 50600, 50602, 50640–50643, 50645–50648

Page 6 

http://www.WilTec.de
http://www.aoyue.eu

 

01 2021

-1

http://www.teichtip.de

Содержание 50600

Страница 1: ...w the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignific antly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Страница 2: ... found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pick up address is WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschweiler Germany To shorten the waiting time and allow for a rapid on site transaction we ask you to call us previously or placing your order...

Страница 3: ...tallation needs to be according to regional and national regulations Protect the vessel piping and any further components from cold temperatures and frost Product Information Expansion vessel The expansion vessel is designed for a maximal pressure of 5 4 bar and thus is tested for its tightness by the manufacturer with up to 5 4 bar water pressure The expansion vessel has a 32 89 33 25 mm connecti...

Страница 4: ...water piping and the pressure switch converter or flow sensor is reduced Installation 1 Remove the protective cap and check the pre charge pressure 2 Check whether the pre charge pressure matches the one stated on the type label The max imal difference is 20 of the pressure indicated 3 With a lower pre charge the pressure needs to be adjusted according to the type plate After wards place the prote...

Страница 5: ... needs to be in creased a bit or the pre charge of the vessel needs to be decreased Repeat these steps until the pumps starts without any interruptions 10 Check the connection on its tightness 11 If everything has been correctly installed the system is ready for use 12 Check the pressure regularly during operation by WilTec Wildanger Technik GmbH Item 50600 50602 50640 50643 50645 50648 Page 5 htt...

Страница 6: ...rom the electricity and let it cool down Ensure that the pre charge pressure matches the one stated on the type label The max toler ance of the pressure is 20 The pre charge pressure should be lower than the start up pressure of the pressure switch and 0 1 0 2 bar below the start up pressure of the pump Never demount the vessel if it is not entirely empty and without pressure Check the pre charge ...

Страница 7: ... by WilTec Wildanger Technik GmbH Item 50600 50602 50640 50643 50645 50648 Page 7 http www WilTec de http www aoyue eu 01 2021 1 http www teichtip de ...

Страница 8: ...pliance is in conformity with the following European directives Cet appareil est conforme aux directives européennes 2014 68 EU Es ist nach folgenden harmonisierten Normen geprüft worden It has been tested with the following harmonised standards Il a été testé à partir des normes harmonisées suivantes EN 13445 1 2014 A1 2014 Bevollmächtigter für die Zusammenstellung der technischen Unterlagen Bern...

Отзывы: