background image

Introduction

Thank you for purchasing this quality product.

 To minimize the risk of injury we urge that our cli-

ents take some basic safety precautions when using this device. Please read the operation in-
structions carefully and make sure you have understood its content.

Keep these operation instructions safe.

Utilisation

The swimming pool pumps are designed for use in small pools (family use), whirlpools and sauna
pools.

Safety instructions

Attention! 

In standing water, garden and swimming ponds and in their vicinity, the use of the device is only
permitted with a residual current circuit breaker with a tripping current of up to 30  mA (according to
VDE 0100 parts 702 and 738).

Maintain a safe distance from the swimming pool and fix the pump on a stable base plate. According
to the VDE standard, a safety distance of 2 m must be maintained.

This device is not intended to be used by persons (including children) with limited physical, sensory or
mental capabilities or a lack of experience and / or knowledge, unless they are supervised by a person
responsible for their safety or have obtained instructions on how to use the device.
Children should be supervised to ensure that they do not play with the device.

Attention!

Perform a visual inspection of the device before each use. Do not use the device if safety
devices are damaged or worn. Never override safety devices.

Only   use   the   device   in   accordance   with   the   intended   use   specified   in   these   operating
instructions.

You are responsible for the safety in the work area.

If the cable or the plug is damaged due to external influences, the cable must not be repaired!
The cable must be exchanged for a new one. This work should only be carried out by a
qualified electrician.

The voltage of 230 V AC specified on the rating plate of the device must correspond to the
existing mains voltage.

Never lift, transport or fasten the device by the power cord.

Make sure that the electrical plug connections are in the flood-proof area or are protected from
moisture.

Pull the power plug before working on the device.

Avoid exposing the device to direct water jets or rain.

© by WilTec Wildanger Technik GmbH 

Item 50374–50377

Page 3 

http://www.WilTec.de
http://www.aoyue.eu

 

11 2020-1

http://www.teichtip.de

Содержание 50374

Страница 1: ... operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignific antly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Страница 2: ...uages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pick up address is WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschweiler Germany To shorten the waiting time and allow for a rapid on site transaction we ask you to call us previously or placin...

Страница 3: ...hey are supervised by a person responsible for their safety or have obtained instructions on how to use the device Children should be supervised to ensure that they do not play with the device Attention Perform a visual inspection of the device before each use Do not use the device if safety devices are damaged or worn Never override safety devices Only use the device in accordance with the intend...

Страница 4: ...avoided Electrical connection The electrical connection is made to an earthed socket with 230 V 50 Hz Fusing at least 6 A The motor is protected against overloading or blocking by the built in thermal motor protection If the device is overheating the motor overheating protection automatically switches off the pump after it has cooled down the pump switches on again automatically Make sure that the...

Страница 5: ...suction and pressure lines must never rest on the pump Make sure that all connections are tight so that the pump does not come into contact with moisture and possibly be damaged We recommend the installation of a foot valve When setting up make sure that the pump is not self priming Operation 1 Fill the system with water to find and repair any leaks 2 Open any slide valves in the pressure and suct...

Страница 6: ...electric pumps do not require any special maintenance Please empty the dirt container regularly The pump body should be emptied before the cold season and if the system is not used for a longer period If the system is not used at all for a long period of time the pump must be cleaned rinsed thoroughly with clean tap water and stored in a dry and well ventilated place Residues of chlorine and other...

Страница 7: ... bar Max 1 1 bar Temperature range 0 35 C liquid 0 35 C liquid 0 35 C liquid 0 35 C liquid Particle width 3 mm 3 mm 3 mm 3 mm Line connection 32 mm 38 mm 11 4 11 2 32 mm 38 mm 11 4 11 2 32 mm 38 mm 11 4 11 2 32 mm 38 mm 11 4 11 2 Protection class IPX4 IPX4 IPX4 IPX4 Cable length 1 5 m 1 5 m 1 5 m 1 5 m Weight 4 8 kg 5 6 kg 9 8 kg 10 8 kg by WilTec Wildanger Technik GmbH Item 50374 50377 Page 7 htt...

Страница 8: ...s out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment By contributing to the correct disposal of this art icle you protect the environment and the health of your fellow men Environment and health are threatened by inappropriate disposal Materials recycling helps reduce the consumpt...

Страница 9: ...enden EG Rats Richtlinien übereinstimmt This appliance is in conformity with the following European directives Cet appareil est conforme aux directives européennes 2014 35 EU Es ist nach folgenden harmonisierten Normen geprüft worden It has been tested with the following harmonised standards Il a été testé à partir des normes harmonisées suivantes EN60335 1 2012 A11 2014 EN60335 2 41 2003 A1 2004 ...

Отзывы: