ENTERPRISE
A8000
IN-BUILDING CELL SIGNAL AMPLIFIER
7
Fasten a sheet of 4’x4’x ¾” plywood utilizing 4x 3/16” x 3” toggle bolts with a
minimum tensile rating of 35 lbs, then use 4x #12 x ¾” Pan Head Wood Screws
to secure the booster to the plywood.
Before assembling and mounting on the wall mount, please reference the
below diagram:
WARNING: Proper installation environment to reduce risks related to the environment, the unit must
be installed indoors only. It is the consumer’s responsibility to ensure that structural engineering
requirements for potential seismic activity are met per your local requirements. This may require
wall reinforcement. Do not install near sources of high heat or steam or where condensation is likely
to occur, such as near air conditioners. Inspect mounting location conditions to ensure proper wall
thickness and no signs of moisture or molding, etc. Do not install on a structure that is prone to
vibration or movement. The unit must be plugged into an earthed outlet ONLY.
Wall Mounting Installation
(for most situations)
Mounting
Specifications
#12 x ¾” Pan Head
Wood Screws
3/16” x 3” Toggle Bolts