Wilo WJ Series Скачать руководство пользователя страница 3

22

English

WILO SE 08/2017

 1. General

See start of document.

 1.1 Application

With the Jet-pump WlLO offers an inexpensive 

water supply unit in the fields of home, hobby and 

garden. The pumps are suitable for:

– watering and sprinkling from ponds, creeks and 

bores,

– draining of tanks and containers,

– dewatering of flooded basements

.

The pump works self-priming (e.g. from bores) or 

with flooded suction (e.g. from open tanks).

It must not be connected directly to public water 
supply systems.

 1.2 Product Information

 1.2.1  Technical Data

Suitable media: Water without solid particles, 
domestic, cold, cooling and rain water. Use of 
other media requires WlLO’s consent.

•  Temperature min./max.

 : 

+ 5 °C to + 35 °C

•  Environment temperature

 min./max. : 

0...40 °C

•  Maximum suction lift : 

8 m

•  Single-phase (EM)

:  

2850 1/min (50 Hz)

•  Three-phase (DM):  

3450 1/min (60 Hz)

•  Size suction/discharge ports:  

G1”

•  Max. working pressure: 

 6 bar

•  Insulation class: 

 130

•  Protection index: 

 IP 44

•  Electrical connection:

 

1 ~ 230 V ±6%, 50 Hz /

   

 

 

  3 ~ 400 V ±6%, 50 Hz /

 

 

   

1 ~ 220-240 V ±6%, 60 Hz

   

 

 

  3 ~ 220-254/380-440 V

 

 

 

 

 

±6%, 60 Hz

When ordering spare parts, please state all name 
plate data.

  2. Safety

See start of document.

 3. Transport and Storage

ATTENTION! 

The pump must not be subjected to 

temperatures outside the limits of 0 °C to +

 

40 °C

.

If the equipment delivered is to be installed at 
some later time, store it in a dry place and pro-

tect it from impacts and all external influences 

(moisture, frost, etc.). 
Handle the pump carrefully so as not to alter the 
geometry and the alignment of the hydraulic 
unit. 
Never suspend the pump from the power cord.

 4. Description of Product and Accessories

All WJ-series pumps are self-priming. AlI parts 
in contact with the medium being handled are of 
corrosion-resistant steel. Single-phase motors 
have built-in thermal contacts, switching off the 
motor on overload and on again after a cooling 
down period. A mechanical seal separates the 
pump housing from the motor.

ATTENTION! 

The pump must not run dry.

Warranty does not cover damages to the pu mp 
due to dryrunning.

  4.1  Description of WJ-Series Pump

Series WJ pumps are portable for mobile applica-
tion. Single phase pumps have a carrying grip and 
are supplied complete with power cable, plug 
and ON/OFF switch.

Standard-Installations

– Figure 1: Pump in suction
– Figure 2: Pump under pressure on storage tank or 

on town water supply with dry-running protec-
tion system.

Legend for Installation samples (see figures 1 and 2

):

Pos. 1 Strainer-foot valve  
           (maximum passing section 1 mm)
Pos. 2 Pump suction valve
Pos. 3 Pump discharge valve
Pos. 4 Non-return valve

Pos. 5 Filling plug

Pos. 6 Draining plug
Pos. 7 Pipe supports
Pos. 8 Strainer
Pos. 9 Storage tank
Pos. 10 Town water supply
Pos. 11 3~ motor protection relay
Pos. 12 OFF/ON switch for single phase motor 
            (red indicator light)
Pos. 13 Power plug (1~ -Motor)

  4.2  Scope of supply

– Jet Pump (WJ)
– Installation and Operation instructions.

 4.3 Accessories

– Suction kit,
– Isolating valves, 
– Non-return valves, 
– Strainer-foot valve, 
– Bladder tank, 
– Vibrationless sleeves, 
– Motor protection relay,
– Dry running protection (ME kit), 
– On-off control device...

The use of new accessories is recommended.

Отзывы: