INSTALLATION                                                                         

 

 

Always use the handle to lift the pump. Never use the power cord to lift the pump. To avoid skin burns, 

unplug the pump and allow time for it to cool after periods of extended use. 

 

1. 

Install the pump on a solid, level foundation, or in a sump pit constructed of tile, concrete, steel, or plastic. The 

recommended minimum diameter of the sump pit is 18" (46cm) diameter and the minimum recommended depth is 30" 

(76cm). Check local codes for approved materials. 

 NOTICE: 

Pump should not be installed on clay, earth, or sand surfaces. 

2. 

Secure the pump on a level, solid base. Do not suspend the pump by the discharge pipe, hose, or power cord. 

3. 

Install 2” discharge pipe into the 2” NPT discharge port. Use rigid plastic pipe and wrap threads with Teflon tape, 

NOT 

pipe joint compound

. Screw pipe into pump hand tight plus 1-1/2 turns.  

4. 

To reduce motor noise and vibrations, a short length of rubber hose can be connected into discharge line near pump 

using suitable clamps. 

5. 

Install a check valve in the horizontal pipe to prevent flow backwards through the pump when it shuts off. Make certain 

the flow indicating arrow points away from the pump. This check valve will keep the water from either running back 

into the basin or into the area being pumped out when the pump is not running. Check valve should be a free flow 

valve that will easily pass solids. 

 NOTICE: 

For best performance of check valve when handling solids, do not install it with discharge angled more than 

45° above the horizontal. Do not install check valve in a vertical position as solids may settle in valve and 

prevent opening on startup. 

6. 

Drill a 1/8” hole in discharge pipe about 1"-2” (2.5 - 5.1cm) above pump discharge connection (but below check valve) 

to prevent air-locking the pump. 

7. 

A tethered piggyback switch is mounted on the pump. The length of the tether (distance of cord from float to clamp) 

should not be set around 3.5 inches and should not be used in a basin smaller than 14 inches in diameter. If using a 

differential other than the factory setting, be sure when the pump shuts off at least 4” of fluid is left in the basin so the 

impeller remains submerged. Insert the float switch piggy-back plug into a properly grounded outlet and the pump 

plug into the piggyback plug. 

8. 

After the installation of the necessary plumbing, check valve, and rubber hose, follow the glue manufacturer’s 

instructions for safety precautions and curing time. The pump is ready for operation. Pump is designed for 115 V., 60Hz, 

operation and requires a minimum 15 amp individual branch circuit.  

9. 

Check the pump by filling the sump pit with water and observe the pump’s operation through one complete cycle. 

Make sure the pump cannot move in the sump and float switch moves freely up and down.  

Содержание WCC17-20.50

Страница 1: ...Wilo SP Series Submersible Sewage Pumps WCC WCC17 20 50 Installation and operating instructions...

Страница 2: ...nol etc Do not use in the presence of flammable or explosive vapors Using this pump with or near flammable liquids can cause explosion or fire resulting in serious personal injury or death and or prop...

Страница 3: ...personal injury and or property damage 6 Check that all hose connections are tight to minimize leaks 7 Connect the pump DIRECTLY to a grounded GFCI outlet 8 Extension cords may not deliver sufficient...

Страница 4: ...he pump is not running Check valve should be a free flow valve that will easily pass solids NOTICE For best performance of check valve when handling solids do not install it with discharge angled more...

Страница 5: ...shut off the pump before it is damaged When the motor has cooled sufficiently the overload protector will reset and the motor will restart NOTICE If the overload protector stops the pump repeatedly di...

Страница 6: ...ipped breaker 3 Plug disconnected 4 Corroded plug 5 Thermal overload 6 Clogged impeller 7 Motor failed 8 Float failed 9 Water level too low 10 Tangled switch 1 Replace fuse 2 Reset breaker 3 Secure pl...

Страница 7: ...arge 5 Impeller broken 1 Clean out debris 2 Inspect check valve and make sure it s properly installed 3 Remove the blockage 4 Remove debris 5 Replace impeller Pump starts and stops too often 1 Backflo...

Страница 8: ...a com Web www wilo usa com Wilo Canada Inc Bay 7 2915 10th Ave NE Calgary AB T2A 5L4 Tel 866 945 6236 Fax 403 277 9456 Email info wilo canada com Web www wilo canada com Wilo Mexico Managua No 978 Col...

Отзывы: