Installation and operating instructions Wilo-Sub TWI4-6

5

• Shrinkage hoses, or moulded sleeves (for motor 

cable extension)

• Pressure vessel, tank
• WILO Fluidcontrol or WILO pressure switching ER 

as Plug & Pump package (see separate installation 
and operating instructions)

6 Description and function

6.1 Description of the pump (Fig. 4) 

Fully submersible, multistage submersible pump 
with radial or semi-axial impellers. Coupling and 
flange usable for motors with pumps, installation 
dimensions in compliance with NEMA standards. 
Built-in non-return valve in the pump head. Inter-
mediate bearing in each stage, specially designed 
to optimise the shaft bearings. Sturdy cable pro-
tection. Optimised hydraulics components for 
achieving high efficiency. High resistance against 
corrosion and abrasion, thanks to the qualities of 
the stainless steel. Easy servicing, thanks to sim-
ple dismantling and installation characteristics of 
the unit.
Corrosion-free single-phase or three-phase 
motor with enamelled windings in hermetically 
cast stator for direct starting with self-lubricating 
bearings.
Motor cooling is achieved by transferring lost heat 
to the fluid around the outer jacket of the motor. 
The minimum flow speed of the fluid along the 
motor is 10 cm/sec for a 4" motor is and is 
16 cm/sec for a 6" motor.

6.2 Soft starter and frequency converter

As a general rule all motors can, within the limits 
described in the following, be operated in combi-
nation with frequency converters and electronic 
starters (soft starter).

CAUTION! Danger of material damage!
If these operating requirements are not met, the 
service life of the pump will be reduced and can 
destroy the motor!

6.2.1 Requirements when using electronic starters 

(soft starter)

• The minimum required cooling flow speed must 

be ensured at all duty points 
(4" motors - 10 cm/sec, 6" motors - 16 cm/sec.)

• The current consumption must remain below the 

nominal current (In) level during the entire oper-
ation (see name plate information).

• The ramp time for the start/stop procedures 

between 0 and 30 Hz should be set to maximum 
1 sec. The ramp time between 30 Hz and the 
nominal frequency should be set to maximum 
3 sec.

• During start-up the voltage must be at least 55 % 

of the nominal motor voltage.

• After normal operation has been reached, bridge 

the electronic starter (soft starter) in order to 
avoid power dissipation during operation.

6.2.2  Requirements when using frequency convert-

ers

• Permanent operation can only be ensured 

between 30 Hz and 50 Hz (60 Hz).

• A time of min. 60 seconds between pump stop and 

restart is recommended to cool the motor wind-
ing.

• Never exceed the nominal current (see name plate 

information).

Maximum voltage peak: 1000 V
Maximum rate of voltage rise: 500 V/

μ

s

• Additional filters are required if the control volt-

age required exceeds 400 V.

• During start-up the voltage must be at least 55 % 

of the nominal motor voltage.

7 Installation and electrical connection

DANGER! Risk of fatal injury!
Incorrect installation and incorrect electrical 
connection can result in death. 

• Installation and electrical work must only be 

done by qualified personnel and in accordance 
with applicable regulations!

• Accident prevention regulations must be 

observed.

7.1 Installation

The pump can be installed vertically or horizon-
tally with a cooling jacket pipe.

CAUTION! Danger of material damage!
Danger of damage due to incorrect handling. 
Boreholes or pumping stations must be 
arranged/designed according to generally valid 
rules of technology.
CAUTION! Danger of material damage!
If installed in a > 4" or 6" borehole (see Fig. 4) or 
if installed horizontally in a tank, it is imperative 
that a suction shroud is fitted on the pump and 
motor in order to ensure sufficient motor cool-
ing

Pos.

Description of component

1

Wilo-Sub pump DM version

2

Submersible electrode ground 

3

Submersible electrode low water

4

Submersible electrode upper level

5

Motor connecting cable

6

Dynamic level (pump in operation)

7

Static level (pump switched-off)

8

Switchbox (with dry-running protection system)

9

Mains supply

10

Pressure switch with pressure gauge

11

Pressure vessel/tank

12

Shut-off valve

13

Non-return valve

Содержание Sub TWI 4

Страница 1: ...Wilo Sub TWI 4 6 Pioneering for You 4 069 717 Ed 04 2021 10 Wilo en Installation and operating instructions...

Страница 2: ...Fig 1 Fig 2 Fig 3 M 1 L a b c d N M 3 U V W d b c a L 1 L 2 L 3 P E a d b c c a b M 3 Fig 4 Fig 5 Fig 6 0 30 1 00 m 1 6 7 5 4 3 2 8 9 10 11 12 13 Min 0 20 E E C D...

Страница 3: ...blems 2 2 Personnel qualifications The installation personnel must have the appro priate qualifications for this work 2 3 Danger in the event of non observance of the safety instructions Non observanc...

Страница 4: ...roduct The pumps are not suitable for water containing coarsecontaminantssuchasfibresorflammable liquids or for use in potentially explosive areas Correct use of the pump installation also includes fo...

Страница 5: ...formation The ramp time for the start stop procedures between 0 and 30 Hz should be set to maximum 1 sec The ramp time between 30 Hz and the nominal frequency should be set to maximum 3 sec During sta...

Страница 6: ...al non return valve and shut off valve on the borehole output CAUTION Danger of material damage When the water pressure is raised 180 m Ws a non return valve must be installed directly at the pump out...

Страница 7: ...55 92 147 30 00 67 108 37 00 89 45 00 73 Cable weight kg m 0 20 0 25 0 30 0 40 0 65 0 85 Diameters and max lengths of the cable 6 motors for star delta start Motor version Motor Cable kW 4 x 1 5 mm 4...

Страница 8: ...rtionally to the motor power see table above NOTE Do not operate the motors where the fluid temperature exceeds 55 C 8 4 Checking and correcting the motor filling level Fig 6 The checking and correcti...

Страница 9: ...e switch setting of the triggering current strength and compare it with the nominal current being drawn The pump starts too often Reduce the number of starting procedures danger of motor overheating a...

Страница 10: ......

Страница 11: ......

Страница 12: ...Pioneering for You WILO SE Wilopark 1 D 44263 Dortmund Germany T 49 0 231 4102 0 F 49 0 231 4102 7363 wilo wilo com www wilo com Local contact at www wilo com contact...

Отзывы: