Installation
20
WILO AG 02/2008
Engl
ish
5.2
Electrical connections
1.
Install a permanent connecting cable with at
5–8 mm outside diameter with plug device or
all-pole switch (with at least 3 mm contact
opening width).
2.
Open the connection box.
3.
Guide the connecting cable through the cable
connection and strip approximately 5 mm.
4.
Secure the cores with the cable clips:
L phase, N neutral, earth.
5.
Tighten the cable connection firmly.
6.
Close the connection box.
5.3
Filling and ventilation
1.
Fill the system.
2.
The pump rotor space vents automatically
after a short time in operation.The pump will
not be damaged if it runs dry briefly.
5.4
Set the time
The timer of the Star-Z 15 C versions can be set
as follows:
1.
Turn the time selection wheel (1) in the direc-
tion of the arrow to set the current time.
2.
Switch the timer on (2) and off (3) on the time
selection wheel as required.
Danger:
Only a qualified electrician is
allowed to work on the electrical connec-
tion.Before making the connection, make sure
that the connecting cable is dead.
1
2
3
4
5
6
7
8
9
10
11
12
13
1
4
15
16
1
7
18
19
20
21
22
23
24
23
1
3 2
Содержание Star-Z 15
Страница 62: ... 62 WILO AG 02 2008 1 PN 10 PN 30 I 230 V 50 Hz 22 W Imax 0 25mA 69 65 67 70 73 65 71 63 67 68 ...
Страница 72: ... 72 WILO AG 02 2008 6 X _ _ Q _ _ _ Y Y 69 7 Y X _ _ _ Y Y Y X _ Y Y _ Q Q 69 ...
Страница 134: ...9 134 WILO AG 02 2008 1 PN 10 PN 30 I 230 V 50 Hz 22 W Imax 0 25mA 141 137 139 142 146 137 143 135 139 140 ...
Страница 147: ... Wilo Star Z 15 147 ...