![Wilo PD-300EA-10M-AU Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/wilo/pd-300ea-10m-au/pd-300ea-10m-au_owners-manual_983208009.webp)
- 9 -
TROUBLES AND COUNTER-MEASURES
Troubles
Cause
Counter-Measures
(The indication
•
can be done by user.)
Motor does not
start.
T.P
Cord disconnected.
Trouble in motor.
Too low power
supply voltage.
Replace the new cord.
Repair or replace the motor.
•
Consult with the power supply
company.
Water level is lower than
standard level.
Water is not
pumped out
although motor
runs.
T.P for motor
works too often.
•
Check the water level
Trouble in the
connection pipe.
•
After checking the joint of
piping shut them perfectly.
Too low or high power
supply voltage.
•
Consult with the power supply
company.
Impeller is in contact with
another part.
Repair the defects.
Short or open circuit of
the capacitor.
Replace the capacitor.
•
If the motor is overheated, it doesn’t
operate.
Then, wait till getting cold.
(20~40 minutes)